The DOI matches its Crossref record; 68 of the 68 references it cites were found in a registry or an index.
Label-free plasmonic biosensors for point-of-care diagnostics: a review
Open accessAbstract
Introduction: Optical biosensors, particularly those based on nanoplasmonics technology, have emerged in recent decades as a potential solution for disease diagnostics and therapy follow-up at the point-of-care (POC). These biosensor platforms could overcome some of the challenges faced in conventional diagnosis techniques offering label-free assays with immediate results and employing small and user-friendly devices.Areas covered: In this review, we will provide a critical overview of the recent advances in the development of nanoplasmonic biosensors for the POC diagnostics. We focus on those systems with demonstrated capabilities for integration in portable platforms, highlighting some of the most relevant diagnostics applications targeting proteins, nucleic acids, and cells as disease biomarkers.Expert commentary: Despite the attractive features of label-free nanoplasmonic sensors in terms of miniaturization and analytical robustness, the route toward an effective clinical implementation involves the integration of fully automated microfluidic systems for sample processing and analysis, and the optimization of surface biofunctionalization procedures. Additionally, the development of multiplexed sensors for high-throughput analysis and including specific neoantigens and novel biomarkers in detection panels will provide the means for delivering a powerful analytical technology for an accurate and improved medical diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“They rely on the combination of specific bioreceptors with transducing elements that detect in real-time the presence of analytes in the liquid samples (176).”
From Tumor-Induced Inflammatory Cytokines and the Emerging Diagnostic Devices for Cancer Detection and Prognosis (2021) · cites this paper as [176]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Formation and Structure of Self-Assembled Monolayers
Ulman, A. (1996) · Chemical Reviews · doi:10.1021/cr9502357 · Cited by 8,055
Surface plasmon resonance sensors: review
Homola, J., Yee, S. S., & Gauglitz, G. (1999) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(98)00321-9 · Cited by 5,518
Cell-free nucleic acids as biomarkers in cancer patients
Schwarzenbach, H., Hoon, D. S. �., & Pantel, K. (2011) · Nature reviews. Cancer · doi:10.1038/nrc3066 · Cited by 2,897
Polymer surface modification for the attachment of bioactive compounds
Goddard, J. M., & Hotchkiss, J. H. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.04.002 · Cited by 1,410
Surface Plasmon Resonance: A Versatile Technique for Biosensor Applications
Nguyen, H. H., Park, J., Kang, S., & Kim, M. (2015) · Sensors · doi:10.3390/s150510481 · Cited by 1,372
Label-free detection and molecular profiling of exosomes with a nano-plasmonic sensor
Im, H., Shao, H., Park, Y. I., Peterson, V. M., Castro, C. M., Weissleder, R., & Lee, H. (2014) · Nature Biotechnology · doi:10.1038/nbt.2886 · Cited by 1,331
Surface Plasmon Resonance Clinical Biosensors for Medical Diagnostics
Masson, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00763 · Cited by 671
Effect of Mutation Order on Myeloproliferative Neoplasms
Ortmann, C. A., Kent, D. G., Nangalia, J., Silber, Y., Wedge, D. C., Grinfeld, J., Baxter, E. J., Massie, C. E., Papaemmanuil, E., Menon, S., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1412098 · Cited by 607
Optical Biosensors for the Detection of Pathogenic Microorganisms
Yoo, S. M., & Lee, S. Y. (2015) · Trends in biotechnology · doi:10.1016/j.tibtech.2015.09.012 · Cited by 596
Localized Surface Plasmon Resonance Biosensing: Current Challenges and Approaches
Unser, S., Bruzas, I., He, J., & Sagle, L. B. (2015) · Sensors · doi:10.3390/s150715684 · Cited by 592
Aptamer-based biosensors for biomedical diagnostics
Zhou, W., Huang, P. J., Ding, J., & Liu, J. (2014) · The Analyst · doi:10.1039/c4an00132j · Cited by 539
Orientation and characterization of immobilized antibodies for improved immunoassays (Review)
Welch, N. G., Scoble, J. A., Muir, B. W., & Pigram, P. J. (2017) · Biointerphases · doi:10.1116/1.4978435 · Cited by 415
Magnetic digital microfluidics – a review
Zhang, Y., & Nguyen, N. (2017) · Lab on a Chip · doi:10.1039/c7lc00025a · Cited by 371
Handheld high-throughput plasmonic biosensor using computational on-chip imaging
Çetin, A. E., Coskun, A. F., Galarreta, B. C., Huang, M., Herman, D. H., Özcan, A., & Altug, H. (2014) · Light Science & Applications · doi:10.1038/lsa.2014.3 · Cited by 358
Integrated planar optical waveguide interferometer biosensors: A comparative review
Kozma, P., Kehl, F., Ehrentreich‐Förster, E., Stamm, C. G., & Bier, F. F. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.02.049 · Cited by 325
Multiplex Serum Cytokine Immunoassay Using Nanoplasmonic Biosensor Microarrays
Chen, P., Chung, M. T., McHugh, W. M., Nidetz, R., Li, Y., Fu, J., Cornell, T. T., Shanley, T. P., & Kurabayashi, K. (2015) · ACS Nano · doi:10.1021/acsnano.5b00396 · Cited by 322
LSPR Chip for Parallel, Rapid, and Sensitive Detection of Cancer Markers in Serum
Aćimović, S. S., Ortega, M. A., Sanz, V., Berthelot, J., Garcia-Cordero, J. L., Renger, J., Maerkl, S. J., Kreuzer, M. P., & Quidant, R. (2014) · Nano Letters · doi:10.1021/nl500574n · Cited by 310
Biosensing with optical fiber gratings
Chiavaioli, F. E., Baldini, F., Tombelli, S., Trono, C., & Giannetti, A. E. (2017) · Nanophotonics · doi:10.1515/nanoph-2016-0178 · Cited by 291
Multiparametric plasma EV profiling facilitates diagnosis of pancreatic malignancy
Yang, K. S., Im, H., Hong, S., Pergolini, I., del Castillo, A. F., Wang, R., Clardy, S. M., Huang, C.-H., Pille, C., Ferrone, S., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aal3226 · Cited by 280
Cancer biomarkers: knowing the present and predicting the future
Chatterjee, S. K., & Zetter, B. R. (2005) · Future Oncology · doi:10.1517/14796694.1.1.37 · Cited by 266
Surface Plasmon Resonance Imaging Sensors: A Review
Wong, C. L., & Olivo, M. (2014) · Plasmonics · doi:10.1007/s11468-013-9662-3 · Cited by 263
Joshi, G. K., McElyea, S. D., Liyanage, T., Lawrence, K. N., Mali, S. S., Sardar, R., & Korc, M. (2015) · ACS Nano · doi:10.1021/acsnano.5b04527 · Cited by 255
Biomarkers: Mining the Biofluid Proteome
Veenstra, T. D., Conrads, T. P., Hood, B. L., Avellino, A. M., Ellenbogen, R. G., & Morrison, R. S. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500006-mcp200 · Cited by 247
A smartphone based surface plasmon resonance imaging (SPRi) platform for on-site biodetection
Güner, H., Özgür, E., Köktürk, G., Celik, M., Esen, E., Topal, A. E., Ayas, S., Uludağ, Y., Elbüken, Ç., & Dâna, A. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.08.061 · Cited by 230
Oliverio, M., Perotto, S., Messina, G. C., Lovato, L., & Angelis, F. D. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b01583 · Cited by 224
Portable Microfluidic Integrated Plasmonic Platform for Pathogen Detection
Tokel, O., Yıldız, Ü. H., İnci, F., Durmus, N. G., Ekiz, O. Ö., Türker, B., Cetin, C., Rao, S., Sridhar, K., Natarajan, N., et al. (2015) · Scientific Reports · doi:10.1038/srep09152 · Cited by 210
Šípová, H., Zhang, S., Dudley, A. M., Galas, D. J., Wang, K., & Homola, J. (2010) · Analytical Chemistry · doi:10.1021/ac102131s · Cited by 209
Ertürk, G., Özen, H., Tümer, M. A., Mattìasson, B., & Deni̇zli̇, A. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.10.093 · Cited by 206
MIP-Based Sensors: Promising New Tools for Cancer Biomarker Determination
Selvolini, G., & Marrazza, G. (2017) · Sensors · doi:10.3390/s17040718 · Cited by 197
Aptamer-Based Au Nanoparticles-Enhanced Surface Plasmon Resonance Detection of Small Molecules
Wang, J., & Zhou, H. S. (2008) · Analytical Chemistry · doi:10.1021/ac801281c · Cited by 185
Diseases as network perturbations
del Sol, A., Balling, R., Hood, L., & Galas, D. J. (2010) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2010.07.010 · Cited by 184
Nanoplasmonic Quantitative Detection of Intact Viruses from Unprocessed Whole Blood
İnci, F., Tokel, O., Wang, S., Gurkan, U. A., Taşoğlu, S., Kuritzkes, D. R., & Demirci, U. (2013) · ACS Nano · doi:10.1021/nn3036232 · Cited by 182
Coskun, A. F., Çetin, A. E., Galarreta, B. C., Alvarez, D. A., Altug, H., & Özcan, A. (2014) · Scientific Reports · doi:10.1038/srep06789 · Cited by 153
Microfluidic Surface Plasmon Resonance Sensors: From Principles to Point-of-Care Applications
Wang, D.-S., & Fan, S. (2016) · Sensors · doi:10.3390/s16081175 · Cited by 153
Wang, Q., Li, Q., Yang, X., Wang, K., Du, S., Zhang, H., & Nie, Y. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.10.091 · Cited by 148
Yoo, S. M., Kim, D.-K., & Lee, S. Y. (2014) · Talanta · doi:10.1016/j.talanta.2014.09.003 · Cited by 147
Nanoplasmonic biosensor: Detection and amplification of dual bio-signatures of circulating tumor DNA
Anh, N. T. V., & Sim, S. J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.09.003 · Cited by 143
Soler, M., Belushkin, A. A., Cavallini, A., Kebbi‐Beghdadi, C., Greub, G., & Altug, H. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.03.047 · Cited by 142
Self-citationHill, R. T. (2014) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1314 · Cited by 133
Bertucci, A., Manicardi, A., Candiani, A., Giannetti, S., Cucinotta, A., Spoto, G., Konstantaki, M., Pissadakis, S., Selleri, S., & Corradini, R. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.047 · Cited by 101
Self-Referenced Smartphone-Based Nanoplasmonic Imaging Platform for Colorimetric Biochemical Sensing
Wang, X., Chang, T.-W., Lin, G., Gartia, M. R., & Liu, G. L. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b02484 · Cited by 94
Yavas, O., Aćimović, S. S., García-Guirado, J., Berthelot, J., Dobosz, P., Sanz, V., & Quidant, R. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00305 · Cited by 94
Gomez-Cruz, J., Nair, S., Manjarrez-Hernández, Á. H., Parra, S. G., Ascanio, G., & Escobedo, C. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.01.055 · Cited by 84
Direct Detection of Point Mutations in Nonamplified Human Genomic DNA
D’Agata, R., Breveglieri, G., Zanoli, L. M., Borgatti, M., Spoto, G., & Gambari, R. (2011) · Analytical Chemistry · doi:10.1021/ac2021932 · Cited by 82
Shekhar, S., Kumar, R. K., Rai, N., Kumar, V. L., Singh, K. K., Upadhyay, A. D., Tripathi, M., Dwivedi, S. N., Dey, A. B., & Dey, S. (2016) · PLoS ONE · doi:10.1371/journal.pone.0159099 · Cited by 80
Label-free SPR detection of gluten peptides in urine for non-invasive celiac disease follow-up
Soler, M., Estévez, M. ‐., Moreno, M. D. L., Cebolla, Á., & Lechuga, L. M. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.11.097 · Cited by 73
Self-citationBiosensors for liquid biopsy: circulating nucleic acids to diagnose and treat cancer
Bellassai, N., & Spoto, G. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9806-3 · Cited by 71
Methylsorb: A Simple Method for Quantifying DNA Methylation Using DNA–Gold Affinity Interactions
Sina, A. A. I., Carrascosa, L. G., Palanisamy, R., Rauf, S., Shiddiky, M. J. A., & Trau, M. (2014) · Analytical Chemistry · doi:10.1021/ac502214z · Cited by 70
Applications of Optical Microcavity Resonators in Analytical Chemistry
Wade, J. H., & Bailey, R. C. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041742 · Cited by 70
Soler, M., Estévez, M. ‐., Villar-Vázquez, R., Casal, J. I., & Lechuga, L. M. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.04.059 · Cited by 70
Self-citationNovel biosensing methodologies for improving the detection of single nucleotide polymorphism
Chang, K., Deng, S., & Chen, M. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.11.041 · Cited by 66
Millington, D. S., Norton, S. M., Singh, R. P., et al. (2018) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2018.1495076 · Cited by 57
Hao, K., He, Y., Lu, H., Pu, S., Zhang, Y., Dong, H., & Zhang, X. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.12.006 · Cited by 50
Prospects of optical biosensors for emerging label-free RNA analysis
Carrascosa, L. G., Huertas, C. S., & Lechuga, L. M. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.02.018 · Cited by 49
Self-citationDNA aptamer-based surface plasmon resonance sensing of human C-reactive protein
Yang, X., Wang, Y., Wang, K., Wang, Q., Wang, P., Lin, M., Chen, N., & Tan, Y. (2014) · RSC Advances · doi:10.1039/c4ra05011h · Cited by 46
Label-free DNA-methylation detection by direct ds-DNA fragment screening using poly-purine hairpins
Huertas, C. S., Aviñó, A. M., Kurachi, C., Piqué, A., Sandoval, J., Eritja, R., Esteller, M., & Lechuga, L. M. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.08.027 · Cited by 44
Self-citationSensitive and label-free detection of miRNA-145 by triplex formation
Aviñó, A. M., Huertas, C. S., Lechuga, L. M., & Eritja, R. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-9180-6 · Cited by 40
Self-citationAntibody Immobilization and Surface Functionalization Chemistries for Immunodiagnostics
Vashist, S. K., & Luong, J. H. T. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-811762-0.00002-5 · Cited by 38
Kurita, R., Yanagisawa, H., Yoshioka, K., & Niwa, O. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03520 · Cited by 36
Label-Free Detection of Rare Cell in Human Blood Using Gold Nano Slit Surface Plasmon Resonance
Mousavi, M. Z., Chen, H., Hou, H.-S., Chang, C.-Y.-Y., Roffler, S. R., Wei, P., & Cheng, J. (2015) · Biosensors · doi:10.3390/bios5010098 · Cited by 32
Kim, J., Kim, S., Nguyen, T. T., Lee, R., Li, T., Yun, C., Ham, Y., An, S. S. A., & Ju, H. (2016) · Journal of Electronic Materials · doi:10.1007/s11664-015-4292-5 · Cited by 32
Huertas, C. S., Carrascosa, L. G., Bonnal, S., Valcárcel, J., & Lechuga, L. M. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.11.023 · Cited by 29
Self-citationKinetic discrimination of DNA single-base mutations by localized surface plasmon resonance
Rapisarda, A., Giamblanco, N., & Marletta, G. (2016) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2016.10.026 · Cited by 29
Sahu, V., Gupta, A., Kumar, R. K., Gupta, T., Mohan, A., & Dey, S. (2016) · Clinica Chimica Acta · doi:10.1016/j.cca.2016.07.009 · Cited by 20
Microfluidics-Enabled Diagnostic Systems: Markets, Challenges, and Examples
Becker, H., & Gärtner, C. (2017) · Methods in molecular biology · doi:10.1007/978-1-4939-6734-6_1 · Cited by 16
Surface Plasmon Resonance–Based Immunoassays
Moran, K., Lemass, D., & O’Kennedy, R. J. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-811762-0.00006-2 · Cited by 13
Nanoplasmonic Sensing Combined with Artificial Cell Membranes
Jonsson, M. P., Dahlin, A., & Höök, F. (2012) · Springer eBooks · doi:10.1007/978-1-4614-3933-2_3 · Cited by 7
Methylsorb: A simple method for quantifying DNA methylation using DNA-gold affinity interactions
Shiddiky, M. J. A., Sina, A. A. I., Carrascosa, L. G., et al. (2014) · International Conference on Electrical and Computer Engineering (ICECE) · doi:10.1109/icece.2014.7027002 · Cited by 2
Research works printed but not linked: 6
- St john A, 2014, Clin Biochem Rev, 35, 155
- Lopez GA, 2017, Nanobiosensors Bioanal Appl Gr, 6, 8193
- Acímović SS, 2004, J Am Chem Soc, 126, 9
- Millington D, 2018, Expert Rev Mol Diagn, 1
- Shiddiky MJA, 2014, 8th Int Conf Electr Comput Eng Adv Technol a Better Tomorrow, ICECE, 2015, 17
- Yang KS, 2017, Sci Transl Med, 9
Cited by
Sorted by citations
Qiu, G., Gai, Z., Tao, Y., Schmitt, J., Kullak-Ublick, G. A., & Wang, J. (2020) · ACS Nano · doi:10.1021/acsnano.0c02439 · Cited by 1,059
Biosensors applications in medical field: A brief review
Haleem, A., Javaid, M., Singh, R. P., Suman, R., & Rab, S. (2021) · Sensors International · doi:10.1016/j.sintl.2021.100100 · Cited by 638
Kartikasari, A. E. R., Huertas, C. S., Mitchell, A., & Plebanski, M. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.692142 · Cited by 343
Self-citationSurface Plasmon Resonance for Biomarker Detection: Advances in Non-invasive Cancer Diagnosis
Bellassai, N., D’Agata, R., Jungbluth, V., & Spoto, G. (2019) · Frontiers in Chemistry · doi:10.3389/fchem.2019.00570 · Cited by 213
Tovar-Lopez, F. J. (2023) · Sensors · doi:10.3390/s23125406 · Cited by 206
Metadata
- Authors
- Soler, M., Huertas, C. S., & Lechuga, L. M.
- Affiliations
- Consejo Superior de Investigaciones Científicas (ES)
- Nanobiosensors and Bioanalytical Applications Group, Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC, BIST and CIBER-BBN, Bellaterra, Barcelona, Spain
- Corresponding author
- Soler, Maria
- Venue
- Expert Review of Molecular Diagnostics
- Publisher
- Informa UK Limited
- Published
- 2018-12-05
- Volume
- 19
- Issue
- 1
- Pages
- 71-81
- ISSN
- 1473-7159 (ISSN-L)
- 1744-8352
- OpenAlex
- W2902810208
- Cited by
- 236
- References
- 66
- Citations by year
- 2026: 18 · 2025: 31 · 2024: 32 · 2023: 31 · 2022: 34 · 2021: 51 · 2020: 31 · 2019: 8
- FWCI
- 1.83
- Type
- journal article
- Language
- en
- Open access
- green
- ddd.uab.cat
- Licence
- public-domain
- Locations
- Expert Review of Molecular Diagnostics (publishedVersion)
- PubMed (publishedVersion)
- Dipòsit Digital de Documents de la UAB (Universitat Autònoma de Barcelona) (submittedVersion, public-domain)
- RMIT Research Repository (RMIT University Library) (submittedVersion)
- DIGITAL.CSIC (Spanish National Research Council (CSIC)) (submittedVersion)
- LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) (submittedVersion, public-domain)
- Figshare (submittedVersion, cc-by)
- Funders
- Centres de Recerca de Catalunya
- Institut Català de Nanociència i Nanotecnologia
- Generalitat de Catalunya
- Ministerio de Asuntos Económicos y Transformación Digital, Gobierno de España (SEV-2013-0295)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Gold and Silver Nanoparticles Synthesis and Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Plasmonic and Surface Plasmon Research
- Keywords
- label-free biosensor, plasmonic biosensors, nanoplasmonics, point-of-care testing, portable diagnostic device, microfluidics, surface biofunctionalization, multiplexed sensors, disease biomarkers, protein detection, nucleic acid detection, cell detection, neoantigens
- MeSH terms
- Humans, Biosensing Techniques, Biomarkers, Point-of-Care Systems, Surface Plasmon Resonance, Molecular Diagnostic Techniques, Nanotechnology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review