XXIV. Oscillatory motion of a viscous liquid in a thin-walled elastic tube—I: The linear approximation for long waves
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
(1955). XXIV. Oscillatory motion of a viscous liquid in a thin-walled elastic tube—I: The linear approximation for long waves. The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science: Vol. 46, No. 373, pp. 199-221.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It was this work that was taken up by McDonald and other researchers for application to arterial mechanics [56-58].”
From A brief history of arterial wave mechanics (2009) · cites this paper as [57]
Citations
Cites
1149. Bessel Functions for Engineers
McLachlan, N. W. (1935) · The Mathematical Gazette · doi:10.2307/3605883 · Cited by 641
Wave Propagation in a Viscous Liquid Contained in a Flexible Tube
Morgan, G. W., & Kiely, J. P. (1954) · The Journal of the Acoustical Society of America · doi:10.1121/1.1907335 · Cited by 156
Lambossy, P. (1952) · Helvetica Physica Acta (Switzerland) · Cited by 66
AN EXPERIMENTAL STUDY OF FLOW PATTERNS IN VARIOUS PERIPHERAL ARTERIES
Shipley, R. E., Gregg, D. E., & Schroeder, E. F. (1943) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1943.138.5.718 · Cited by 39
Research works printed but not linked: 4
- Helps E.P.W., 1954, J. Physiology., 154, 30P
- Lamb H., 1898, Mem. Manchester Lit. and Phil. Soc., 42
- Lambossy P., 1952, Helvetica Physica Acta, 25, 371
- Womersley J.R., 1954, J. Physiology., 154, 31P
Cited by
Items 401–480 of 480
Cave, F. D., & Charlesworth, D. C. (1981) · Physics in Medicine and Biology · doi:10.1088/0031-9155/26/6/008 · Cited by 1
CALCULATION OF STEADY AND OSCILLATING FLOWS IN TUBES USING A VORTICITY TRANSPORT ALGORITHM
JOHNSON, A. W., & Gerrard, J. H. (1996) · International Journal for Numerical Methods in Fluids · doi:10.1002/(sici)1097-0363(19961230)23:12<1241::aid-fld472>3.0.co;2-k · Cited by 1
Effects of periodic accelerations on blood flow in arteries
Sud, V. K., VONGIERKE, H., Kaleps, I., & Oestreicher, H. L. (1983) · Bulletin of Mathematical Biology · doi:10.1007/bf02460055 · Cited by 1
Gerrard, J. H. (1982) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441850 · Cited by 1
Forced oscillations in a windkessel model
Lewi, P. J. (1965) · Bulletin of Mathematical Biology · doi:10.1007/bf02478404 · Cited by 1
Independent component analysis based source separation in physiological strain waves
Huang, L., Kucewicz, J. C., & Beach, K. W. (2005) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.2004.1418069 · Cited by 1
“Blood flow was modeled by Womersley’s pulsatile flow model (Womersley 1955).”
MethodA Review of Pulse Propagation in Viscoelastic Arteries with Distributed Flow Leakage
Hoff, C. J., & Yang, W.-J. (1994) · Bio-Medical Materials and Engineering · doi:10.3233/bme-1994-4602 · Cited by 1
Estimation of the blood velocity spectrum using a recursive lattice filter
Jensen, J. A., Buelund, C., Jorgensen, A., & Munk, P. (2002) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.1996.584210 · Cited by 1
“The dynamic characteristics of the non-stationarity are incorporated through an exponential decay factor, that sets the exponential horizon of the filter.”
BackgroundA new 3D ultrasonic model of pathologic carotid vessels based on generalized cylinders
Balocco, S., Basset, O., Cachard, C., Azencot, J., Delachartre, P., & Tortoli, P. (2005) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.2004.1418270 · Cited by 1
“Piomelli “Numerical simulation of pulsating turbulent channel flow” Physics of fluids volume 13, number 5 may 2001 [8] J.”
BackgroundMethodQin, K. R., Wang, S. Z., Wu, H., & Ding, G. (2010) · International Conference on Control and Automation · doi:10.1109/icca.2010.5524285 · Cited by 1
“According to the characteristic of blood flow in rat common carotid arteries, the equations governing the blood flow can be simplified as follows [19], [24]”
BackgroundMethodHydrobionics—a Perspective on Technological Implications of Biological Flows
Bugliarello, G., Wong, A., Hung, T. K., Weissman, M. H., Ahuja, A. S., & Stark, K. P. (1971) · Advances in hydroscience · doi:10.1016/b978-0-12-021807-3.50010-2 · Cited by 1
A STUDY OF THE MECHANICAL IMPEDANCE TO FLOW IN THE FEMORAL PERIPHERAL VASCULAR BED OF THE DOG
Yanof, H. M., & Stacy, R. W. (1960) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/4127042 · Cited by 1
Diallo, A. D. (2019) · theses.fr (ABES) · doi:10.70675/4b11f956z9d5dz4d28z96d5z783ae1dcd5b8 · Cited by 1
Application of Computer Vision to Transport Phenomena
Aminfar, A. (2019) · eScholarship (California Digital Library) · Cited by 1
Taylor, C. A. (2004) · Wiley eBooks · doi:10.1002/0470091355.ecm068 · Cited by 1
Instabilités et transition à la turbulence dans les écoulements périodiques
Frantz, R. A. S. (2022) · theses.fr (ABES) · doi:10.70675/bf73ae81zfd91z4febzab4dze221076c7fab · Cited by 1
Multi-scale simulation of automotive catalytic converters
Ozhan, C. (2014) · theses.fr (ABES) · doi:10.70675/dfcdcea0zb268z49adzbf73z1915e50059ed · Cited by 1
From Non-Invasive Hemodynamic Measurements towards Patient-Specific Cardiovascular Diagnosis
Bernhard, S., Zoukra, K. A., & Schtte, C. (2012) · IGI Global eBooks · doi:10.4018/978-1-4666-2455-9.ch106 · Cited by 1
Fluid Mechanics in Cardiovascular Research Cardiac Valve Flow Dynamics
Kang, Z. H. (1987) · Springer eBooks · doi:10.1007/978-94-009-3355-2_7
Experiments and Numerical Analysis Relating to Atherogenesis
Gerrard, J. H. (1990) · Springer eBooks · doi:10.1007/978-1-4757-1511-8_35
Struijk, P. C. (2006) · RePub (Erasmus University Rotterdam) · Cited by 2
Chatterjee, S. (1997) · Iowa State University Digital Repository (Iowa State University) · doi:10.31274/rtd-180813-10479
A nonlinear analysis of flow in an elastic artery model-steady streaming effects
Wang, D. M., & Tarbell, J. M. (2002) · IEEE Annual Northeast Bioengineering Conference (NEBEC) · doi:10.1109/nebc.1990.66285
Axially symmetric wave motion of a viscous liquid in a linearly viscoelastic tube
Amenzadze, R. Y. (1977) · Mechanics of Composite Materials · doi:10.1007/bf00856465
Lagrée, P., & Rossi, M. (1995) · Archives of Physiology and Biochemistry · doi:10.3109/13813459509037289
Effect of initial twist on wave characteristics in a prestressed fluid-filled elastic thin tube
Demíray, H. (1997) · Applied Mathematical Modelling · doi:10.1016/s0307-904x(97)88865-8 · Cited by 1
The mechanical properties of glutaraldehyde stabilized human umbilical vein measured in vivo
Chapman, B. L. W., & Charlesworth, D. C. (1983) · British journal of surgery · doi:10.1002/bjs.1800700908
Quasisteady arterial blood flow
Gordon, P. F. (1983) · Journal of Mathematical Physics · doi:10.1063/1.525764
Buchner, T., & Sobiech, T. (2014) · Conference of the European Study Group on Cardiovascular Oscillations (ESGCO) · doi:10.1109/esgco.2014.6847575
“Womersley [9] introduced a simplifications of the NavierStokes for an elastic tube for harmonic pressure modes of”
MethodEffects of transients on pulsatile flow in arteries
Brereton, G. J. (2011) · Biorheology · doi:10.3233/bir-2011-0591 · Cited by 1
Vergara, C. (2010) · Aisberg (University of Bergamo)
Valencia, Á., Figueroa, H., Rivera, R., & Bravo, E. (2010) · Información tecnológica · doi:10.4067/s0718-07642010000500005
Study of the AQD spectral estimator on simulated and in vivo Doppler data
Forsberg, F., & Oung, H. (2002) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.1996.584216
ESTIMATION OF THE BLOOD VELOCITY SPECTRUM USING A
Buelund, C., & Munk, P. (1996)
Carpenter, B. E., & Doran, R. (2015) · ResearchSpace (University of Auckland)
Cylindrical Shells Containing or Immersed in Flow
Païdoussis, M. P. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-397333-7.00001-2
Non- Newtonian behavior of blood in very narrow vessels
Chaubey, A. K. C. A. K. (2013) · IOSR Journal of Mathematics · doi:10.9790/765x-0637882
Blood through a Rough Thin-Walled Elastic Tube
Saha, G. C. (2010)
Lifli Kalın Tüplerde Artık Gerilmenin Dalga Yalımına Etkisi
Erol, H. (2014) · Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi · doi:10.19113/sdufbed.18093
Arterial narrowing and flow-pressure changes.
Gwee, A. L., & Teh, Y. F. (1967) · PubMed
Cappa, P., Cannella, M., & Varoto, P. S. (2001) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
Techniques in Fluid Dynamical Wall Shear Phenomena and Their Application in the Blood Flow
Nakamura, M. (2000) · CRC Press eBooks · doi:10.1201/9781420049558.ch-02
Fluid Dynamics for Bio Systems: Fundamentals and Model Analysis
Peattie, R. A., & Fisher, R. J. (2012) · CRC Press eBooks · doi:10.1201/b12937-5
STUDY OF VISCO-ELASTIC BLOOD FLOW IN A LOCALLY CONSTRICTED TUBE
Haldar, K. (1988) · Elsevier eBooks · doi:10.1016/b978-0-08-036232-8.50184-5
Computational Modeling of the Human Cardiovascular System
Sharma, P. K., Lucian Mihai, I. T. U., & Suciu, C. (2017) · Springer eBooks · doi:10.1007/978-3-319-56853-9_1
A Well-Balanced Discontinuous Galerkin Method for the Blood Flow Model
Yao, Z., Li, G., & Song, L. (2017) · Journal of Mathematical Study · doi:10.4208/jms.v50n2.17.04
Accuracy and precision study of plane wave vector flow imaging for laminar and complex flow in vivo
Jensen, J., Hoyos, C. A. V., Olesen, J. B., Tomov, B. G., Traberg, M. S., Moshavegh, R., Stuart, M. B., Ewertsen, C., Hansen, K. L., Nielsen, M. B., et al. (2017) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2017.8092956
Computer simulation of coronary blood flow
Frake, B. C. (1995) · Iowa State University Digital Repository (Iowa State University) · doi:10.31274/rtd-180813-10012
An Efficient High Order Well-Balanced Finite Difference WENO Scheme for the Blood Flow Model
Qian, S., Li, G., Lv, X., & Shao, F. (2018) · Advances in Applied Mathematics and Mechanics · doi:10.4208/aamm.oa-2016-0151
Hydro-elasticity of a Bulge Wave Energy Converter in the 2D Frank Close-Fit Method
Kemp, L. F. (2019) · Research Repository (Delft University of Technology)
Polyanin, A. D., & Zaitsev, V. F. (2011) · Chapman & Hall/CRC eBooks · doi:10.1201/b11412-49
Modeling of Fluid Flow in a Flexible Vessel with Elastic Walls
Kozlov, V., Nazarov, S., & Zavorokhin, G. (2021) · Journal of Mathematical Fluid Mechanics · doi:10.1007/s00021-021-00607-w
The Influence of Drag on Nonlinear Oscillatory Flow through Concentric Annulus
Umadevi, B., Vinay, C. V., & Dinesh‐Kumar, S. P. (2021) · Molecular & cellular biomechanics · doi:10.32604/mcb.2021.015605
“KEYWORDS Particle drag; oscillatory flow; catheter Nomenclature R; h; Zð Þ: Cylindrical coordinate system U ; 0;Wð Þ: Velocity vector of the fluid phase U 0; 0; W 0ð Þ: Velocity vector of particulate phase P: Pressure q: Density of the fluid t: Time N : Number density of the particles m: Kinematic viscosity of the flu…”
BackgroundInfluential(1962) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1962.tb02411.x
Perfusion Effects and Hydrodynamics
Peattie, R. A., & Fisher, R. J. (2009) · Springer eBooks · doi:10.1007/978-3-540-77755-7_46
(2016) · Elsevier eBooks · doi:10.1016/b978-0-12-397333-7.09973-3
(2014) · Elsevier eBooks · doi:10.1016/b978-0-12-397312-2.00029-6
Lung Ventilation Modeling and Medical Assessment
Loh, K. M., Ghista, D. N., & Su, B. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-95884-4.00005-6
Pulsatile flow of biviscous fluid through a tube of varying cross-section
Govindan, V., Xin, X., Narayanamoorthy, N. S., Geetha, P., Chithra, S. M., Nagaraj, C. T., Premkumar, M., & Bala, A. J. (2023) · Modern Physics Letters B · doi:10.1142/s0217984923410051
Magrab, E. B. (2024) · Solid mechanics and its applications · doi:10.1007/978-3-031-52102-7_8
Могилевич, Л. И., Blinkov, Y. A., Попова, Е. В., & Popov, V. S. (2024) · Izvestiya VUZ Applied Nonlinear Dynamics · doi:10.18500/0869-6632-003115
Popov, V. S., Popova, A. A., Chernenko, A. V., & Popova, M. V. (2025) · Učenye zapiski Kazanskogo gosudarstvennogo universiteta. Seriâ Fiziko-matematičeskie nauki/Učënye zapiski Kazanskogo universiteta. Seriâ Fiziko-matematičeskie nauki · doi:10.26907/2541-7746.2025.2.329-350
Oscillatory Flow and Solute Transport in an Elastic Tube under the Influence of Suction/Injection
Tabassum, F., & Muthu, P. (2025) · Computational Mathematics and Mathematical Physics · doi:10.1134/s0965542525700897
“Womersley [3] developed a foundational model to study oscillatory motion in thin-walled elastic tubes with uniform cross-sections, providing an analytical framework for long-wave dynamics.”
Brereton, G. J. (2025) · Physics of Fluids · doi:10.1063/5.0289990
Xu, Z., Lin, Z., Zhang, Z., Jiang, H., Liu, C., Xu, X., Wang, C., Zhang, H., & Li, H. (2025) · International Conference on Bioinformatics and Biomedical Technology (ICBBT) · doi:10.1109/icbbt65815.2025.11276191
“According to Womersley model [7], which is based on linear Navier-Stokes equations and elastic tube with thin wall assumption, the governing equations under cylinder coordinate system along a single artery can be expressed as The velocity profile was obtained for pulsatile flow in a rigid tube [8] as…”
Benakcha, Y., Hadj-Ali, R., Ghezal, A., & Loraud, J. (2009) · DSpace (Centre National De La Recherche Scientifique)
Wolk, K. J., & Dhir, V. K. (2026) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2026.128643
Mesyanzhin, A. V. (2026) · Вестник КРАУНЦ Физико-математические науки · doi:10.26117/2079-6641-2026-54-1-104-123
Ventre, J. (2020) · theses.fr (ABES) · doi:10.70675/5fbdbdb3z42b1z45c8z98cbzcc927c83cc38 · Cited by 6
Fluid Dynamic Modeling of Biological Fluids : From the Cerebrospinal Fluid to Blood Thrombosis
Cardillo, G. (2020) · theses.fr (ABES) · doi:10.70675/d6b91367zce61z41fbza860z06709d32e040
Etude des échanges de chaleur sous un écoulement pulsé : application à des machines thermiques
Blanc, M. (2022) · theses.fr (ABES) · doi:10.70675/dc9befaaz6badz4f4ezb4c3za185ed01da9a
Conception systémique de machines électriques pour la réfrigération magnétocalorique.
Eustache, J. (2025) · theses.fr (ABES) · doi:10.70675/6574aac8z61fbz4908za7fdzbb0738ed9ce9
Usman, M., Castillo, P. N., Narayan, A., & Timmins, L. H. (2026) · Journal of Biomechanical Engineering · doi:10.1115/1.4071773
Pulsatile flow driven electrokinetic energy conversion in a deformable isotropic microtube
Dutta, B., Singh, B. P., & Goswami, P. (2026) · European Journal of Mechanics - B/Fluids · doi:10.1016/j.euromechflu.2026.204612
Cut-off frequency of micromachined regenerators as possibly used in miniaturized cryocoolers
Ayela, F., Bataille, B., Colombet, D., Luchier, N., & Medrano, M. (2026) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2026.107071
Popov, V. S., Могилевич, Л. И., & Popova, A. A. (2026) · Journal of Fluids and Structures · doi:10.1016/j.jfluidstructs.2026.104731
A theoretical model of oscillatory blood flow in arteries
Keshavarzi, M., & Kline, K. A. (1974) · Proceedings of the Indian Academy of Sciences - Section A · doi:10.1007/bf03051325
Metadata
- Authors
- Womersley, J. R.
- Affiliations
- Queen Mary University of London (GB)
- Corresponding author
- Womersley, J.R.
- Venue
- The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science
- Publisher
- Informa UK Limited
- Published
- 1955-02
- Volume
- 46
- Issue
- 373
- Pages
- 199-221
- ISSN
- 1941-5982 (ISSN-L)
- 1941-5990
- OpenAlex
- W1964983166
- Cited by
- 472
- References
- 4
- Citations by year
- 2026: 7 · 2025: 10 · 2024: 8 · 2023: 14 · 2022: 15 · 2021: 11 · 2020: 14 · 2019: 9 · 2018: 14 · 2017: 15 · 2016: 12 · 2015: 14 · 2014: 16 · 2013: 6 · 2012: 12
- FWCI
- 15.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- The London Edinburgh and Dublin Philosophical Magazine and Journal of Science (publishedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Vibration and Dynamic Analysis
- Physical Sciences › Engineering › Computational Mechanics › Fluid dynamics and aerodynamics studies
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Rheology and Fluid Dynamics Studies
- Keywords
- oscillatory flow, viscous fluid, long waves, linearization, blood flow
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.