Factors related to uncomfortable loudness levels for patients seen in a tinnitus and hyperacusis clinic
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: The aims were as follows: (1) to explore patterns of uncomfortable loudness levels (ULLs) across frequency and their associated factors for patients with tinnitus and hyperacusis, and (2) to re-evaluate the criteria for diagnosing hyperacusis based on ULLs and scores for the Hyperacusis Questionnaire (HQ). DESIGN: This was a retrospective cross-sectional study. STUDY SAMPLE: 573 consecutive patients for whom ULLs had been measured were included. RESULTS: A good correspondence between the diagnosis of hyperacusis based on the across-frequency average ULL for the ear with the lowest ULLs (ULLmin) and hyperacusis handicap based on HQ scores was obtained with cut-off values of ULLmin ≤77 dB HL and HQ score ≥ 22. A regression model showed significant relationships between ULLmin and the score on the HQ and age. The mean HQ score for patients with a large interaural asymmetry in ULLs was significantly higher than for the remainder. Hyperacusis handicap was associated with strong across-frequency variations in ULLs. CONCLUSIONS: Appropriate cut-off values for diagnosing hyperacusis are ULLmin ≤77 dB HL and HQ score ≥22. Large interaural asymmetry and large across-frequency variations in ULLs are associated with higher HQ scores.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Validation of the Insomnia Severity Index as an outcome measure for insomnia research
Bastien, C. (2001) · Sleep Medicine · doi:10.1016/s1389-9457(00)00065-4 · Cited by 8,067 · cited 2×
“Scores from 0 to 7 indicate no clinically significant insomnia, scores from 8 to 14 indicate minimal insomnia, scores from 15 to 21 indicate moderate insomnia, and scores from 22 to 28 indicate severe insomnia (Bastien et al, 2001).”
BackgroundMethodPsychometric Normalization of a Hyperacusis Questionnaire
Khalfa, S., Dubal, S., Veuillet, E., Perez-Diaz, F., Jouvent, R., & Collet, L. (2002) · ORL · doi:10.1159/000067570 · Cited by 488
A review of hyperacusis and future directions: Part I. Definitions and manifestations
Tyler, R. S., Pienkowski, M., Roncancio, E. R., Jun, H. J., Brozoski, T., Dauman, N., Coelho, C. B., Andersson, G., Keiner, A. J., Cacace, A. T., et al. (2014) · American Journal of Audiology · doi:10.1044/2014_aja-14-0010 · Cited by 329 · cited 5×
“The sounds may be perceived as uncomfortably loud, unpleasant, frightening, or painful (Tyler et al, 2014).”
BackgroundMethodResultSelf-citationThe brain basis for misophonia
Kumar, S., Tansley-Hancock, O., Sedley, W., Winston, J. S., Callaghan, M. F., Allen, M., Cope, T. E., Gander, P. E., Bamiou, D.-E., & Griffiths, T. D. (2017) · Current Biology · doi:10.1016/j.cub.2016.12.048 · Cited by 290 · cited 1×
“…our patients classified as having hyperacusis might be an indication of adverse reactions only to specific sounds, which is consistent with the definitions of annoyance and fear hyperacusis (Tyler et al, 2014) and misophonia (Jastreboff & Jastreboff, 2014; Cavanna & Seri, 2015; Kumar et al, 2017).”
ResultHypersensitivity to sound: Questionnaire data, audiometry and classification
Anari, M., Axelsson, A., Eliasson, A., & Magnusson, L. (1999) · Scandinavian Audiology · doi:10.1080/010503999424653 · Cited by 271 · cited 4×
“However, the average ULLs reported for patients with hyperacusis vary widely across studies, from 66.3 dB HL (SD¼15) (Blaesing & KroenerHerwig, 2012) to 77 dB HL (Anari et al, 1999), and 83 dB HL (SD¼ 17) (Sheldrake et al, 2015).”
BackgroundInfluentialTreatments for decreased sound tolerance (hyperacusis and misophonia)
Jastreboff, M., & Jastreboff, P. (2014) · Seminars in Hearing · doi:10.1055/s-0034-1372527 · Cited by 245
Misophonia: Current perspectives
Cavanna, A. E., & Seri, S. (2015) · Neuropsychiatric Disease and Treatment · doi:10.2147/ndt.s81438 · Cited by 135 · cited 1×
“…our patients classified as having hyperacusis might be an indication of adverse reactions only to specific sounds, which is consistent with the definitions of annoyance and fear hyperacusis (Tyler et al, 2014) and misophonia (Jastreboff & Jastreboff, 2014; Cavanna & Seri, 2015; Kumar et al, 2017).”
ResultSherlock, L. P., & Formby, C. (2005) · Journal of the American Academy of Audiology · doi:10.3766/jaaa.16.2.4 · Cited by 127 · cited 6×
“Sherlock & Formby (2005) reported that the lowest 5th percentile values of ULLs for 59 normal-hearing adults without sound tolerance problems were 80, 85, 80 and 75 dB HL at 0.5, 1, 2 and 4 kHz, respectively. Therefore, ULLs of 80 dB HL or above may be considered as within the normal range while ULLs less than 80 dB H…”
BackgroundResultInfluentialPsychiatric comorbidity and personality traits in patients with hyperacusis
Jüris, L., Andersson, G., Larsen, H. C., & Ekselius, L. (2013) · International Journal of Audiology · doi:10.3109/14992027.2012.743043 · Cited by 114 · cited 1×
“More recently, Juris et al (2013) used ULLs below 90 dB HL in one or both ears (averaged across 0.5, 1, 2 and 3 kHz) as one of their criteria for including patients in a study of hyperacusis.”
MethodInfluentialFackrell, K., Fearnley, C., Hoare, D. J., & Sereda, M. (2015) · BioMed Research International · doi:10.1155/2015/290425 · Cited by 110 · cited 2×
“Meeus et al (2010) suggested reducing the cut-off score to 26, while Fackrell et al (2015) suggested that the cut-off score of 28 needs to be revaluated but did not propose a definitive value.”
Background
Cited by
Aazh, H., Landgrebe, M., Danesh, A. A., & Moore, B. C. (2019) · Psychology Research and Behavior Management · doi:10.2147/prbm.s179138 · Cited by 75
“in sensitivity to sound, which is an indication of adverse reactions only to specific sounds, a feature associated with misophonia.(44,45) In the field of psychiatry, there is a growing debate about whether misophonia is a distinct psychiatric disorder.”
BackgroundSelf-citationSiepsiak, M., Rosenthal, M. Z., Raj-Koziak, D., & Dragan, W. (2022) · Journal of Psychosomatic Research · doi:10.1016/j.jpsychores.2022.110777 · Cited by 60
Aazh, H., & Moore, B. C. J. (2018) · American Journal of Audiology · doi:10.1044/2018_aja-17-0096 · Cited by 51
Self-citationAazh, H., Bryant, C., & Moore, B. C. J. (2019) · American Journal of Audiology · doi:10.1044/2019_aja-19-0045 · Cited by 22
Self-citationClinical and investigational tools for monitoring noise-induced hyperacusis
Jahn, K. N. (2022) · The Journal of the Acoustical Society of America · doi:10.1121/10.0012684 · Cited by 20
Metadata
- Authors
- Aazh, H., & Moore, B. C. J.
- Venue
- International Journal of Audiology
- Publisher
- Informa UK Limited
- Published
- 2017-06-16
- Volume
- 56
- Issue
- 10
- Pages
- 793-800
- ISSN
- 1499-2027 (ISSN-L)
- 1708-8186
- OpenAlex
- W2625011504
- Cited by
- 113
- References
- 11
- FWCI
- 3.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Factors related to uncomfortable loudness levels for patients seen in a tinnitus and hyperacusis clinic. https://app.cochat.ai/papers/10.1080/14992027.2017.1335888
- The paper
- Aazh, H., & Moore, B. C. J. (2017). Factors related to uncomfortable loudness levels for patients seen in a tinnitus and hyperacusis clinic. International Journal of Audiology. https://doi.org/10.1080/14992027.2017.1335888
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.