The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Optimal Sizing of Distributed Generation Placed on Radial Distribution Systems
Abstract
Distribution network planning identifies the least cost network investment that satisfies load growth requirements without violating any system and operational constraints. Power injections from distributed generation change network power flows, modifying energy losses. Determining appropriate location and optimal size of distributed generation with respect to network configuration and load distribution in the feeder is main challenge in the changing regulatory and economic scenarios. Among the benefits of distributed generation is the reduction in active power losses, which can improve the system performance; reliability, and efficiency. In this article, the multi-location distributed generation placement problem aims to minimize the total active power loss of radial distribution networks using a genetic algorithm based solution algorithm. This technical benefit of energy savings due to the reduction in active power loss can also be translated into economic benefits. The loss sensitivity to the change in active power injection is used in selecting candidate location(s) for installation of distributed generation devices. A comparison of the results for loss reduction and savings with other reported methods show the effectiveness of the proposed method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optimal capacitor placement on radial distribution systems
Baran, M. E., & Wu, F. F. (1989) · IEEE Transactions on Power Delivery · doi:10.1109/61.19265 · Cited by 2,062
Cited by
Georgilakis, P. S., & Hatziargyriou, N. D. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2237043 · Cited by 875
Abu-Mouti, F. S., & El-Hawary, M. E. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2158246 · Cited by 725
Ehsan, A., & Yang, Q. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.10.106 · Cited by 524
El-Fergany, A. (2015) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2014.09.020 · Cited by 409
Ant Lion Optimization Algorithm for optimal location and sizing of renewable distributed generations
Ali, E. S., Abd Elazim, S. M., & Abdelaziz, A. Y. (2017) · Renewable Energy · doi:10.1016/j.renene.2016.09.023 · Cited by 366
Metadata
- Authors
- Shukla, T. N., Singh, S. P., Srinivasarao, V., & Naik, K. B.
- Venue
- Electric Power Components and Systems
- Publisher
- Informa UK Limited
- Published
- 2010-01-29
- Volume
- 38
- Issue
- 3
- Pages
- 260-274
- ISSN
- 1532-5008 (ISSN-L)
- 1532-5016
- OpenAlex
- W2151394022
- Cited by
- 202
- References
- 1
- FWCI
- 4.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal Sizing of Distributed Generation Placed on Radial Distribution Systems. https://app.cochat.ai/papers/10.1080/15325000903273403
- The paper
- Shukla, T. N., Singh, S. P., Srinivasarao, V., & Naik, K. B. (2010). Optimal Sizing of Distributed Generation Placed on Radial Distribution Systems. Electric Power Components and Systems. https://doi.org/10.1080/15325000903273403
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.