Active Versus Passive Cooling During Work in Warm Environments While Wearing Firefighting Protective Clothing
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
This study examined whether active or passive cooling during intermittent work reduced the heat strain associated with wearing firefighting protective clothing (FPC) and self-contained breathing apparatus (SCBA) in the heat (35 degrees Celsius, 50% relative humidity). Fifteen male Toronto firefighters participated in the heat-stress trials. Subjects walked at 4.5 km.h(-1) with 0% elevation on an intermittent work (50 min) and rest (30 min) schedule. Work continued until rectal temperature (T(re)) reached 39.5 degrees Celsius, or heart rate (HR) reached 95% of maximum or exhaustion. One of three cooling strategies, forearm submersion (FS), mister (M), and passive cooling (PC) were employed during the rest phases. Tolerance time (TT) and total work time (WT) (min) were significantly increased during FS (178.7 +/- 13.0 and 124.7 +/- 7.94, respectively) and M (139.1 +/- 8.28 and 95.1 +/- 4.96, respectively), compared with PC (108.0 +/- 3.59 and 78.0 +/- 3.59). Furthermore, TT and WT were significantly greater in FS compared with M. Rates of T(re) increase, HR and T-(sk) were significantly lower during active compared with passive cooling. In addition, HR and T(re) values in FS were significantly lower compared with M after the first rest phase. During the first rest phase, T(re) dropped significantly during FS (approximately 0.4 degree Celsius) compared with M (approximately 0.08 degree Celsius) while PC increased (approximately 0.2 degree Celsius). By the end of the second rest period T(re) was 0.9 degree Celsius lower in FS compared with M. The current findings suggest that there is a definite advantage when utilizing forearm submersion compared with other methods of active or passive cooling while wearing FPC and SCBA in the heat.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1992) · Applied Ergonomics · doi:10.1016/0003-6870(92)90318-p · Cited by 5,737
The Gross Composition of the Body
SIRI, W. E. (1956) · Advances in Biological and Medical Physics · doi:10.1016/b978-1-4832-3110-5.50011-x · Cited by 1,765 · cited 1×
“Body fatness was calculated using the Siri equation.((32))”
MethodGagge, A. P., Stolwijk, J. A. J., & Hardy, J. D. (1967) · Environmental Research · doi:10.1016/0013-9351(67)90002-3 · Cited by 1,093 · cited 2×
“A subjective rating of thermal comfort (RTC) was completed immediately following metabolic gas exchange measurements using a modified version of Gagge et al.(38) The 524 Journal of Occupational and Environmental Hygiene August 2004 RTC scale ranged from 7 (“comfortable”) to 13 (“so hot I am sick and nauseated”).”
MethodThe Technic of Measuring Radiation and Convection
Hardy, J. D., Du Bois, E. F., & Soderstrom, G. F. (1938) · The Journal of Nutrition · doi:10.1093/jn/15.5.461 · Cited by 849
Respiratory weight losses during exercise.
Mitchell, J. W., Nadel, E. R., & Stolwijk, J. A. (1972) · Journal of Applied Physiology · doi:10.1152/jappl.1972.32.4.474 · Cited by 361
An Introduction to Statistical Methods and Data Analysis
Ziegel, E. R., & Ott, L. (1994) · Technometrics · doi:10.2307/1269399 · Cited by 336
CHARACTERIZATION OF THE PHYSICAL DEMANDS OF FIREFIGHTING.: 32
Jamnik, V., & Gledhill, N. (1989) · Medicine and Science in Sports and Exercise · doi:10.1249/00005768-198904001-00032 · Cited by 328
Advances in Biological and Medical Physics
Nias, A. H. W. (1966) · International Journal of Radiation Biology and Related Studies in Physics, Chemistry and Medicine · doi:10.1080/09553006614550861 · Cited by 304
Smith, D. L., Manning, T. S., & Petruzzello, S. J. (2001) · Ergonomics · doi:10.1080/00140130010000910 · Cited by 239
Exercise duration and thermoregulatory responses after whole body precooling
Lee, D. T., & Haymes, E. M. (1995) · Journal of Applied Physiology · doi:10.1152/jappl.1995.79.6.1971 · Cited by 185 · cited 1×
“Various methods for cooling have been reported, including precooling,((17,18)) liquid and air cooling systems,((16,19,20)) water immersion of the extremities, both hands and feet,((23)) as well as fan cooling.”
MethodCotter, J. D., Sleivert, G. G., Roberts, W. S., & Febbraio, M. A. (2001) · Comparative Biochemistry and Physiology Part A Molecular & Integrative Physiology · doi:10.1016/s1095-6433(01)00273-2 · Cited by 156 · cited 1×
“Various methods for cooling have been reported, including precooling,((17,18)) liquid and air cooling systems,((16,19,20)) water immersion of the extremities, both hands and feet,((23)) as well as fan cooling.”
MethodSMITH, D. L., PETRUZZELLO, S. J., KRAMER, J. M., & MISNER, J. E. (1997) · Ergonomics · doi:10.1080/001401397188125 · Cited by 133
Mean body temperature and the control of thermal sweating.
Snellen, J. W. (1966) · PubMed · Cited by 126
Heat stress in protective clothing. Interactions among physical and physiological factors.
Nunneley, S. A. (1989) · PubMed · Cited by 119
Physical Work Limits for Toronto Firefighters in Warm Environments
Selkirk, G. A., & McLellan, T. M. (2004) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620490432114 · Cited by 114 · cited 3×
“described in detail.((13)) The work portion consisted of walking at 4.”
BackgroundSelf-citationPhysiological Responses of Men Working in Fire Fighting Equipment in the Heat
DUNCAN, H. W., GARDNER, G. W., & JAMES BARNARD, R. (1979) · Ergonomics · doi:10.1080/00140137908924636 · Cited by 106
The human energy cost of fire fighting
Lemon, P. W. R., & Hermiston, R. T. (1983) · Applied Ergonomics · doi:10.1016/0003-6870(83)90101-1 · Cited by 97
Influence of menstrual cycle and oral contraceptives on tolerance to uncompensable heat stress
Tenaglia, S. A., McLellan, T. M., & Klentrou, P. (1999) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/s004210050561 · Cited by 91 · cited 3×
“Liquid and air cooling systems offering continuous((16)) and intermittent((19)) microclimate cooling”
BackgroundMethodSelf-citationPulmonary function testing guidelines and controversies : equipment, methods, and normal values
Clausen, J. L., & Abramson, J. F. (1982) · Academic Press eBooks · Cited by 85
CARTER, J. B., Banister, E. W., & Morrison, J. B. (1999) · Ergonomics · doi:10.1080/001401399185667 · Cited by 76 · cited 3×
“0C, it continued to rise during subsequent recovery periods.((24)) Therefore, it remains to be seen how effective active fan cooling would be following additional bouts of work as firefighters approach critical limits.”
BackgroundMethodInfluentialEfficacy of air and liquid cooling during light and heavy exercise while wearing NBC clothing.
McLellan, T. M., Frim, J., & Bell, D. G. (1999) · PubMed · Cited by 69
Self-citationFaff, J., & TUTAK, T. (1989) · Ergonomics · doi:10.1080/00140138908966137 · Cited by 68 · cited 1×
“However, it has been found that with hot and/or humid conditions, rectal temperature (Tre) will not decrease during passive rest, and, in fact, will continue to increase during the designated rest periods due to the environmental conditions.((7,9,13,14)) Thus, when ambient temperatures are high, the implementation of…”
BackgroundAustin, C. C., Dussault, G., & Ecobichon, D. J. (2001) · American Journal of Industrial Medicine · doi:10.1002/ajim.10023 · Cited by 55
Intermittent microclimate cooling during rest increases work capacity and reduces heat stress
Constable, S. H., Bishop, P. A., Nunneley, S. A., & CHEN, T. (1994) · Ergonomics · doi:10.1080/00140139408963645 · Cited by 53 · cited 5×
“Depending on the working conditions, these methods have the potential to change an uncompensable working environment to compensable.((19,25)) Another approach is to adapt the technology of these devices into portable units.”
BackgroundMethodInfluentialSmith, D. L., Petruzzello, S. J., Kramer, J. M., Warner, S., Bone, B., & MISNER, J. E. (1995) · Ergonomics · doi:10.1080/00140139508925251 · Cited by 48 · cited 2×
“However, it has been found that with hot and/or humid conditions, rectal temperature (Tre) will not decrease during passive rest, and, in fact, will continue to increase during the designated rest periods due to the environmental conditions.((7,9,13,14)) Thus, when ambient temperatures are high, the implementation of…”
BackgroundWhite, M. K., & Hodous, T. K. (1988) · American Industrial Hygiene Association Journal · doi:10.1080/15298668891380169 · Cited by 42
McLellan, T. M., Gannon, G. A., Zamecnik, J., Gil, V., & Brown, G. M. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.1.308 · Cited by 36 · cited 1×
“m.((34)) On arrival, subjects inserted a rectal probe and were weighed nude on an electronic scale, sensitive to the nearest 0.”
MethodSelf-citationFOURTH PAPER THE DETERMINATION OF THE BASAL METABOLISM OF NORMAL MEN AND THE EFFECT OF FOOD
Gephart, F. C. (1915) · Archives of Internal Medicine · doi:10.1001/archinte.1915.00070240044004 · Cited by 36 · cited 1×
“Body surface area was calculated using the DuBois equation.((29)) Body density was determined from underwater weighing using body plethysmography to determine residual lung volume.”
Method
Cited by
Jay, O., Capon, A., Berry, P., Broderick, C., de Dear, R., Havenith, G., Honda, Y., Kovats, R. S., Ma, W., Malik, A., et al. (2021) · The Lancet · doi:10.1016/s0140-6736(21)01209-5 · Cited by 737
Cardiovascular Disease in US Firefighters: A Systematic Review
Soteriades, E. S., Smith, D. L., Tsismenakis, A. J., Baur, D. M., & Kales, S. N. (2011) · Cardiology in Review · doi:10.1097/crd.0b013e318215c105 · Cited by 419
“9 L/h during strenuous firefighting activity.(49,59,64) Smith et al(49) reported a 15% reduction in plasma volume after 3 bouts of strenuous firefighting activity that can have significant physiologic impacts, such as decreased stroke volume.”
BackgroundThe thermal ergonomics of firefighting reviewed
Barr, D., Gregson, W., & Reilly, T. (2010) · Applied Ergonomics · doi:10.1016/j.apergo.2009.07.001 · Cited by 244
“, 1999), misting fans (Selkirk et al., 2004), and hand and forearm immersion in water (House, 1994, 1996, 1997; McTiffin,1994; Selkirk et al.”
BackgroundMethodInfluentialClothing for protection against heat and flames
Rossi, R. (2014) · Protective Clothing · doi:10.1533/9781782420408.1.70 · Cited by 17
Metadata
- Authors
- Selkirk, G. A., McLellan, T. M., & Wong, J.
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2004-08
- Volume
- 1
- Issue
- 8
- Pages
- 521-531
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- OpenAlex
- W1986941648
- Cited by
- 166
- References
- 28
- FWCI
- 1.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.