CoChat

An Evaluation of the Physiological Strain Experienced by Electrical Utility Workers in North America

Meade, Robert D., Lauzon, Martin, Poirier, Martin P., Flouris, Andreas D., Kenny, Glen P. · 2015 · Journal of Occupational and Environmental Hygiene
Cited by 74

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

The purpose of this study was to assess the physiological strain experienced by North American electrical utility workers during the performance of their normal work duties in heat stressed conditions. Three common job categories were monitored as they are normally performed in 32 electrical utility workers: (i) Ground Work (n = 11); (ii) Bucket Work (n = 9); and (iii) Manual Pole Work (n = 12). Worker hydration status (urine specific gravity (USG)) was measured prior to and following the work monitoring period (duration: 187 ± 104 min). Core and skin temperatures as well as heart rate were measured continuously. Physiological Strain Index (PSI) was calculated from the measurements of core temperature and heart rate. Prior to the start of the work shift, 38% of workers were euhydrated (USG < 1.020; n = 12) whereas the majority of workers were dehydrated (USG > 1.020; prevalence: 75%; p < 0.01) following work. The overall mean and peak core temperatures for all monitored workers were 37.9 ± 0.3 °C and 38.3 ± 0.5 °C, respectively. When responses were compared between job categories, greater mean and peak increases in core temperature were observed in Manual Pole Work relative to the other job categories (both p < 0.04). In fact, six workers performing Manual Pole Work achieved core temperatures in excess of 38.5 °C, while only one other worker surpassed this threshold in Bucket Work. The high levels of thermal strain were paralleled by elevated mean and peak heart rate and PSI responses, which were greater in Manual Pole Work in comparison to the other job categories (all p ≤ 0.05). Furthermore, two workers performing Manual Pole Work achieved severely elevated core temperatures reaching or exceeding 39.5 °C along with prolonged periods of near maximal heart rate responses (i.e., >90% of heart rate reserve). We report elevated levels of thermal and cardiovascular strain in electrical utility workers during work in the heat and potentially dangerous levels of hyperthermia during particularly strenuous work.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/15459624.2015.1043054

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 74

Metadata

Authors
Meade, R. D., Lauzon, M., Poirier, M. P., Flouris, A. D., & Kenny, G. P.
Venue
Journal of Occupational and Environmental Hygiene
Published
2015-09-02
Volume
12
Issue
10
Pages
708-720
ISSN
  • 1545-9624 (ISSN-L)
  • 1545-9632
OpenAlex
W2146296552
Cited by
74
References
5
FWCI
4.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An Evaluation of the Physiological Strain Experienced by Electrical Utility Workers in North America. https://app.cochat.ai/papers/10.1080/15459624.2015.1043054
The paper
Meade, R. D., Lauzon, M., Poirier, M. P., Flouris, A. D., & Kenny, G. P. (2015). An Evaluation of the Physiological Strain Experienced by Electrical Utility Workers in North America. Journal of Occupational and Environmental Hygiene. https://doi.org/10.1080/15459624.2015.1043054

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.