Cited by 14

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Assessment of occupational exposure to asbestos fibers: Contribution of analytical transmission electron microscopy analysis and comparison with phase-contrast microscopy

Eypert-Blaison, Céline, Romero-Hariot, Anita, Clerc, Frédéric, Vincent, Raymond·2018·Journal of Occupational and Environmental Hygiene

Abstract

From November 2009 to October 2010, the French general directorate for labor organized a large field-study using analytical transmission electron microscopy (ATEM) to characterize occupational exposure to asbestos fibers during work on asbestos containing materials (ACM). The primary objective of this study was to establish a method and to validate the feasibility of using ATEM for the analysis of airborne asbestos of individual filters sampled in various occupational environments. For each sampling event, ATEM data were compared to those obtained by phase-contrast optical microscopy (PCOM), the WHO-recommended reference technique. A total of 265 results were obtained from 29 construction sites where workers were in contact with ACM. Data were sorted depending on the combination of the ACM type and the removal technique. For each "ACM-removal technique" combination, ATEM data were used to compute statistical indicators on short, fine and WHO asbestos fibers. Moreover, exposure was assessed taking into account the use of respiratory protective devices (RPD). As in previous studies, no simple relationship was found between results by PCOM and ATEM counting methods. Some ACM, such as asbestos-containing plasters, generated very high dust levels, and some techniques generated considerable levels of dust whatever the ACM treated. On the basis of these observations, recommendations were made to measure and control the occupational exposure limit. General prevention measures to be t…

Overview

Integrity signals

Registry

Crossref · 10.1080/15459624.2017.1412583

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 1 references

Research works printed but not linked: 21

  1. World Health Organization (WHO), 1997, Determination of Airborne Fiber Number Concentration. A Recommended Method by Phase-Contrast Optical Microscopy (Membrane Filter Method)
  2. Agence Francaise de Sécurité Sanitaire de l'Environnement et du Travail (AFSSET), 2009, Influence of asbestos fibers dimensions to the health risk characterization: Toxicological, metrological and epidemiological data review in order to carry out a health risk assessment for the general population and the workers (in French)
  3. Stanton M.F., 1981, J. Natl. Cancer. Inst., 67, 965
  4. 10.1002/ajim.10263 · DOI · Paper page
  5. Association Française de NORmalisation (AFNOR), 1996, NF X 43–050. Qualité de l'air. Détermination de la concentration en fibres d'amiante par microscopie électronique à transmission—Méthode indirecte
  6. Association Française de NORmalisation (AFNOR), 2002, XP X 43–269. Qualité de l'air. Air des lieux de travail. Détermination de la concentration en nombre de fibres par microscopie optique à contraste de phase. Méthode du filtre à membrane
  7. Association Française de NORmalisation (AFNOR), 2012, XP X 43–269. Qualité de l'air. Air des lieux de travail. Prélèvement sur filtre membrane pour la détermination en nombre de fibres par les techniques de microscopie: MOCP, MEBA, META – Comptage par MOCP
  8. Villa M., 1994, J. Int. Soc. Respir. Protect., 12, 7
  9. 10.1080/15298660108984624 · DOI
  10. 10.1093/annhyg/28.3.321 · DOI · Paper page
  11. 10.1080/1047322X.1990.10389630 · DOI
  12. 10.1080/1047322X.1996.10389381 · DOI
  13. 10.1080/1047322X.1998.10389133 · DOI · Paper page
  14. 10.1080/104732202753306168 · DOI
  15. International Standards Organisation (ISO), 1997, Draft International ISO/DIS 13794 Ambient air. Determination of asbestos fibers. Indirect-transfer transmission electron microscopy procedure
  16. 10.1016/0003-4878(95)00079-8 · DOI
  17. 10.1093/annhyg/mep066 · DOI
  18. 10.1080/15298668791385066 · DOI
  19. Cherrie J., 1989, IARC Sci. Publ., 90, 304
  20. European Union (EU), 2009, Directive n° 2009/148/EC of the European Parliament and of the Council of 30 November 2009 on the protection of the workers from the risks related to exposure to asbestos at work
  21. Eypert-Blaison C., 2014, Hygiène et sécurité du travail, 234, 46

Cited by

Sorted by citations

See all 14

Metadata

Authors
Eypert-Blaison, C., Romero-Hariot, A., Clerc, F., & Vincent, R.
Affiliations
  • INRS, Centre de Lorraine, Département Métrologie des Polluants, Vandœuvre Les Nancy Cedex, France
  • INRS, Centre de Paris, Département Expertise et Conseil Technique, Paris, France
  • INRS, Centre de Lorraine, Direction des Applications, Vandœuvre Les Nancy Cedex, France
Venue
Journal of Occupational and Environmental Hygiene
Published
2018-02-26
Volume
15
Issue
3
Pages
263-274
ISSN
  • 1545-9624
  • 1545-9632
Cited by
14
References
1
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of occupational exposure to asbestos fibers: Contribution of analytical transmission electron microscopy analysis and comparison with phase-contrast microscopy. https://app.cochat.ai/papers/10.1080/15459624.2017.1412583
The paper
Eypert-Blaison, C., Romero-Hariot, A., Clerc, F., & Vincent, R. (2018). Assessment of occupational exposure to asbestos fibers: Contribution of analytical transmission electron microscopy analysis and comparison with phase-contrast microscopy. Journal of Occupational and Environmental Hygiene. https://doi.org/10.1080/15459624.2017.1412583