Kinetic Study of NSSC Black Liquor Combustion Using Different Kinetic Models
Abstract
Non-isothermal thermogravimetric analysis experiments were carried out to investigate combustion characteristics of neutral sulfite semi-chemical pulp black liquor solids at a temperature range of room temperature to 800°C with the heating rates of 10, 20, 30, and 50°C · min−1. The results show that there are three temperature ranges, namely volatile matter separating process (170–370°C), volatile matter burning process (370–550°C), and fixed carbon burning and alkali metal salts reacting process (550–800°C), in which the black liquor quickly loses weight. The kinetic parameters were determined for the three reaction regions by using the Kissinger method and the Ozawa method. The activation energies were higher by choosing the Kissinger method over the Ozawa method. Kinetic parameters of neutral sulfite semi-chemical pulp black liquor can supply the theory bases for establishing thermal combustion model.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Detailed pyrolysis kinetics and fast pyrolysis properties of BLS were still lacking.
“Nevertheless, the detailed pyrolysis kinetics and fast pyrolysis properties of BLS were still lacking.”
From Evaluation of pyrolysis characteristics and product distribution of black liquor using Py-GC/MS and down tube reactor: Comparison with lignin (2021) · cites this paper as [20]
The more complex the composition, the greater the Ea fluctuation.
“The more complex the composition was, the greater the Ea fluctuation was [20,21].”
From Evaluation of pyrolysis characteristics and product distribution of black liquor using Py-GC/MS and down tube reactor: Comparison with lignin (2021) · cites this paper as [20]
Cited by
Sorted by citations
Hydrothermal Conversion of Neutral Sulfite Semi-Chemical Red Liquor into Hydrochar
Gamgoum, R., Dutta, A., Santos, R., & Chiang, Y. (2016) · Energies · doi:10.3390/en9060435 · Cited by 41 · see citing works
Zhao, Y., Zhang, H., Zong, P., Zhou, H., & Tian, Y. (2021) · Fuel · doi:10.1016/j.fuel.2021.120286 · Cited by 36 · see citing works
Self-citation
- Authors
- Zhao, Y., Bie, R., Lu, J., & Xiu, T.
- Affiliations
- Harbin Institute of Technology (CN)
- ORCID
- Lu, J.
- Venue
- Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Publisher
- Informa UK Limited
- Published
- 2010-03-12
- Volume
- 32
- Issue
- 10
- Pages
- 962-969
- ISSN
- 1556-7036 (ISSN-L)
- 1556-7230
- OpenAlex
- W2001003339
- Cited by
- 7
- References
- 0
- Citations by year
- 2025: 1 · 2021: 1 · 2018: 1 · 2017: 1 · 2016: 1 · 2015: 1 · 2014: 1
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Energy Sources Part A Recovery Utilization and Environmental Effects (publishedVersion)
- Funders
- Nuclear Safety and Security Commission
- Natural Science Foundation of Heilongjiang Province
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Thermal and Kinetic Analysis
- Physical Sciences › Engineering › Biomedical Engineering › Thermochemical Biomass Conversion Processes
- Physical Sciences › Engineering › Mechanical Engineering › Coal Combustion and Slurry Processing
- Keywords
- black liquor combustion, combustion kinetics, activation energy, non-isothermal thermogravimetry, Kissinger method, Ozawa method, fixed carbon combustion
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review