The DOI matches its Crossref record.
The Morphology of Poly(3,4-Ethylenedioxythiophene)
Abstract
Poly(3,4-ethylene dioxythiophene) (PEDOT) is a chemically stable, conjugated polymer that is of considerable interest for a variety of applications including coatings for interfacing electronic biomedical devices with living tissue. Here, we describe recent work from our laboratory and elsewhere to investigate the morphology of PEDOT in the solid state. We discuss the importance of oxidative chemical and electrochemical polymerization, as well as the critical role of the counterion used during synthesis and film deposition. We have obtained information about the morphology of PEDOT from a number of different complimentary techniques including X-ray diffraction, optical microscopy, scanning electron microscopy, transmission high-resolution electron microscopy, and low-voltage electron microscopy. We also discuss results from ultraviolet-visible light spectroscopy (UV-Vis), Fourier transform infrared spectroscopy (FTIR), and X-ray photoelectron spectroscopy (XPS). PEDOT is a relatively rigid polymer that packs in the solid state at a characteristic face-to-face distance (010) of ∼0.34 nm, similar to graphite. These sheets of oriented PEDOT molecules are separated from one another by ∼1.4 nm laterally, with the (100) distance between layers quite sensitive to the choice of counterion used during sample preparation. The order in the films is typically modest, although this also depends on the counterion used and the method of film deposition. The films can be organized into useful structures with a variety of nanoscale dissolvable templates (including fibers, particles, and lyotropic mesophases). When PEDOT is electrochemically deposited in the presence of bromine counterions, highly ordered crystalline phases are observed. It is also possible to deposit PEDOT around living cells, both in vitro and in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Organic electrochemical transistors
Rivnay, J., Inal, S., Salleo, A., Owens, R. M., Berggren, M., & Malliaras, G. G. (2018) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.86 · Cited by 2,065
Bubnova, O., Khan, Z. U., Wang, H., Braun, S., Evans, D. R., Fabretto, M., Hojati-Talemi, P., Dagnelund, D., Arlin, J.-B., Geerts, Y. H., et al. (2014) · Nature Materials · doi:10.1038/nmat3824 · Cited by 854
Gueye, M. N., Carella, A., Faure-Vincent, J., Demadrille, R., & Simonato, J.-P. (2020) · Progress in Materials Science · doi:10.1016/j.pmatsci.2019.100616 · Cited by 682
Conducting Polymers for Pseudocapacitive Energy Storage
Bryan, A. M., Santino, L. M., Lu, Y., Acharya, S., & D’Arcy, J. M. (2016) · Chemistry of Materials · doi:10.1021/acs.chemmater.6b01762 · Cited by 559
Conducting Polymers in the Fields of Energy, Environmental Remediation, and Chemical–Chiral Sensors
Ibanez, J. G., Rincón, M. E., Gutierrez-Granados, S., Chahma, M., Jaramillo-Quintero, O. A., & Frontana-Uribe, B. A. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00482 · Cited by 493
Metadata
- Authors
- Martin, D. C., Wu, J., Shaw, C. M., King, Z., Spanninga, S. A., Richardson-Burns, S., Hendricks, J., & Yang, J.
- Venue
- Polymer Reviews
- Publisher
- Informa UK Limited
- Published
- 2010-07-27
- Volume
- 50
- Issue
- 3
- Pages
- 340-384
- ISSN
- 0736-6574 (ISSN-L)
- 1558-3724
- 1558-3716
- OpenAlex
- W2058773045
- Cited by
- 182
- References
- 0
- FWCI
- 9.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Morphology of Poly(3,4-Ethylenedioxythiophene). https://app.cochat.ai/papers/10.1080/15583724.2010.495440
- The paper
- Martin, D. C., Wu, J., Shaw, C. M., King, Z., Spanninga, S. A., Richardson-Burns, S., Hendricks, J., & Yang, J. (2010). The Morphology of Poly(3,4-Ethylenedioxythiophene). Polymer Reviews. https://doi.org/10.1080/15583724.2010.495440
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.