CoChat

Uneven distribution of interfacial bond stress in steel fiber-reinforced concrete-encased steel composite structures

Wu, Kai, Qian, Shiyuan, Zheng, Huiming, Zhang, Yanjie, Zhu, Ruizhe · 2024 · Structure and Infrastructure Engineering

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Abstract

To solve the congestion of reinforcement and the difficulty of concrete pouring in concrete-encased steel (CES) structure, steel fiber-reinforced concrete-encased steel (SFRCES) structure was proposed. Push-out tests of 34 SFRCES specimens were carried out in this paper to study the interfacial bond stress distribution, and load-displacement curves were obtained. The interfacial ultimate bond strength calculated based on load-displacement curve is much greater than 0.2 MPa which is the interfacial design shear strength of composite steel and concrete structure in Eurocode 4. This illustrates that the design of SFRCES structure is partial to safety. Furthermore, different from the previous method using the assumption of uniform distribution of interfacial bond stress, the interfacial local bond stress was obtained based on strain data and mechanical derivation in this paper. Moreover, the influence of steel fiber volume rate, embedded length of steel, and thickness of concrete on the distribution of interfacial bond stress was analyzed by defining the uneven coefficient of interfacial bond stress distribution. Analysis results provide a theoretical basis for the design of SFRCES structure and lay a foundation for the application of SFRCES structure in practical engineering.

Overview

Integrity signals

Registry

Crossref · 10.1080/15732479.2022.2162550

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 30 references

Research works printed but not linked: 1

  1. 10.14006/j.jzjgxb.2017.06.006 · doi:10.14006/j.jzjgxb.2017.06.006

Cited by

See all 3

Metadata

Authors
Wu, K., Qian, S., Zheng, H., Zhang, Y., & Zhu, R.
Affiliations
Hohai University (CN)
Corresponding author
Wu, Kai
Venue
Structure and Infrastructure Engineering
Published
2023-01-04
Volume
20
Issue
11
Pages
1714-1730
ISSN
  • 1573-2479 (ISSN-L)
  • 1744-8980
OpenAlex
W4313592075
Cited by
2
References
30
Citations by year
2026: 1 · 2025: 1
FWCI
0.22
Type
journal article
Language
en
Open access
closed
Locations
Structure and Infrastructure Engineering (publishedVersion)
Topics
  • Physical Sciences › Engineering › Civil and Structural Engineering › Structural Load-Bearing Analysis
  • Physical Sciences › Engineering › Building and Construction › Structural Behavior of Reinforced Concrete
  • Physical Sciences › Engineering › Civil and Structural Engineering › Innovative concrete reinforcement materials
Keywords
steel fiber reinforced concrete, composite structures, bond stress distribution, push-out test, Eurocode 4, steel fiber volume fraction, embedded length, concrete thickness, load-displacement behavior

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Uneven distribution of interfacial bond stress in steel fiber-reinforced concrete-encased steel composite structures. https://app.cochat.ai/papers/10.1080/15732479.2022.2162550
The paper
Wu, K., Qian, S., Zheng, H., Zhang, Y., & Zhu, R. (2024). Uneven distribution of interfacial bond stress in steel fiber-reinforced concrete-encased steel composite structures. Structure and Infrastructure Engineering. https://doi.org/10.1080/15732479.2022.2162550

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.