Zirconia in biomedical applications
The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: The use of zirconia in medicine and dentistry has rapidly expanded over the past decade, driven by its advantageous physical, biological, esthetic, and corrosion properties. Zirconia orthopedic hip replacements have shown superior wear-resistance over other systems; however, risk of catastrophic fracture remains a concern. In dentistry, zirconia has been widely adopted for endosseous implants, implant abutments, and all-ceramic crowns. Because of an increasing demand for esthetically pleasing dental restorations, zirconia-based ceramic restorations have become one of the dominant restorative choices. Areas covered: This review provides an updated overview of the applications of zirconia in medicine and dentistry with a focus on dental applications. The MEDLINE electronic database (via PubMed) was searched, and relevant original and review articles from 2010 to 2016 were included. Expert commentary: Recent data suggest that zirconia performs favorably in both orthopedic and dental applications, but quality long-term clinical data remain scarce. Concerns about the effects of wear, crystalline degradation, crack propagation, and catastrophic fracture are still debated. The future of zirconia in biomedical applications will depend on the generation of these data to resolve concerns.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
GARVIE, R. C., HANNINK, R. H., & PASCOE, R. T. (1975) · Nature · doi:10.1038/258703a0 · Cited by 2,291
Transformation Toughening in Zirconia‐Containing Ceramics
Hannink, R. H. J., Kelly, P., & Muddle, B. C. (2000) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.2000.tb01221.x · Cited by 2,268 · cited 1×
“the mechanical strength and fracture toughness of the alumina resulting in high wear resistance and low aging degradation [12,13].”
BackgroundState of the art of zirconia for dental applications
Denry, I., & Kelly, J. R. (2008) · Dental Materials · doi:10.1016/j.dental.2007.05.007 · Cited by 2,133 · cited 1×
“Aside from superior mechanical properties, zirconia has advantageous biological properties: low corrosion potential, low cytotoxicity, and minimal adhesion of bacteria [1,2].”
BackgroundAn overview of zirconia ceramics: Basic properties and clinical applications
Manicone, P. F., Rossi Iommetti, P., & Raffaelli, L. (2007) · Journal of Dentistry · doi:10.1016/j.jdent.2007.07.008 · Cited by 1,369 · cited 1×
“By mixing zirconia with relatively low amounts of other metallic oxides, referred to as ‘dopants,’ the conversion to the monoclinic lattice does not occur during cooling; rather, the tetragonal form is stabilized to a great degree (to a metastable form) at room temperature [4,7].”
BackgroundStabilized zirconia as a structural ceramic: An overview
Kelly, J. R., & Denry, I. (2008) · Dental Materials · doi:10.1016/j.dental.2007.05.005 · Cited by 1,172 · cited 3×
“rial and progresses through its bulk [10,11].”
BackgroundTarnow, D. P., Magner, A. W., & Fletcher, P. (1992) · Journal of Periodontology · doi:10.1902/jop.1992.63.12.995 · Cited by 1,074 · cited 1×
“The results were in accordance to the findings on titanium implants [62].”
ResultE. Jung, R., Zembic, A., Pjetursson, B. E., Zwahlen, M., & S. Thoma, D. (2012) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2012.02547.x · Cited by 1,019
Sailer, I., Makarov, N. A., Thoma, D. S., Zwahlen, M., & Pjetursson, B. E. (2015) · Dental Materials · doi:10.1016/j.dental.2015.02.011 · Cited by 762 · cited 1×
“6% survival rate at 5 years [112], zirconia appears to be a viable alternative to alloy–ceramic under this measure of success.”
BackgroundLughi, V., & Sergo, V. (2010) · Dental Materials · doi:10.1016/j.dental.2010.04.006 · Cited by 692 · cited 1×
“rial and progresses through its bulk [10,11].”
Phase change and mechanical properties of ZrO2-Y2O3 solid electrolyte after ageing
Kobayashi, K., KUWAJIMA, H., & Masaki, T. (1981) · Solid State Ionics · doi:10.1016/0167-2738(81)90138-7 · Cited by 661
From porcelain-fused-to-metal to zirconia: Clinical and experimental considerations
Zarone, F., Russo, S., & Sorrentino, R. (2010) · Dental Materials · doi:10.1016/j.dental.2010.10.024 · Cited by 620 · cited 2×
“By mixing zirconia with relatively low amounts of other metallic oxides, referred to as ‘dopants,’ the conversion to the monoclinic lattice does not occur during cooling; rather, the tetragonal form is stabilized to a great degree (to a metastable form) at room temperature [4,7].”
BackgroundBacterial colonization of zirconia ceramic surfaces: an in vitro and in vivo study.
Rimondini, L., Cerroni, L., Carrassi, A., & Torricelli, P. (2002) · PubMed · Cited by 511
Glauser, R., Sailer, I., Wohlwend, A., Studer, S., Schibli, M., & SCHARER, P. (2004) · PubMed · Cited by 395
The mucosal attachment at different abutments: An experimental study in dogs
Abrahamsson, I., Berglundh, T., Glantz, P. ‐., & Lindhe, J. (1998) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.1998.tb02513.x · Cited by 384 · cited 1×
“It has been shown that zirconia and titanium alloy abutments exhibit equivalent compatibility for connective tissue integration and the formation of epithelial tissue attachment; the connective tissue attachment around the zirconia abutments form a more stable mucosal seal than the conventional gold abutments [71].”
BackgroundZirconia: Established facts and perspectives for a biomaterial in dental implantology
Hisbergues, M., Vendeville, S., & Vendeville, P. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31147 · Cited by 361
The effect of zirconia sintering temperature on flexural strength, grain size, and contrast ratio
Stawarczyk, B., Özcan, M., Hallmann, L., Ender, A., Mehl, A., & Hämmerlet, C. H. F. (2013) · Clinical Oral Investigations · doi:10.1007/s00784-012-0692-6 · Cited by 352 · cited 1×
“the frequency of porcelain fracture in both in-vitro and in-vivo studies [114].”
BackgroundBeuer, F., Schweiger, J., Eichberger, M., Kappert, H. F., GERNET, W., & Edelhoff, D. (2008) · Dental Materials · doi:10.1016/j.dental.2008.04.019 · Cited by 334 · cited 1×
“It has been proposed that differences in coefficients of thermal expansion (CTE) between veneering ceramics and zirconia, the low thermal diffusivity and conductivity of zirconia, the varied thickness of the veneering ceramic, and the design of zirconia substructure could all contribute to the higher incidence of vene…”
BackgroundSennerby, L., Dasmah, A., Larsson, B., & Iverhed, M. (2005) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2005.tb00070.x · Cited by 320
Tooth structure removal associated with various preparation designs for posterior teeth.
Edelhoff, D., & Sorensen, J. A. (2002) · PubMed · Cited by 273
Zembic, A., Sailer, I., Jung, R. E., & Hämmerle, C. H. F. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01717.x · Cited by 263
Akagawa, Y., Ichikawa, Y., Nikai, H., & Tsuru, H. (1993) · Journal of Prosthetic Dentistry · doi:10.1016/0022-3913(93)90289-z · Cited by 246 · cited 1×
“The first reference to the use of zirconia in dentistry was in the 1970s [20]; zirconia was first used an endosseous dental implant in 2008 [21].”
BackgroundProspective Evaluation of Zirconia Posterior Fixed Partial Dentures: 7-Year Clinical Results
Rinke, S., Gersdorff, N., Lange, K., & Roediger, M. (2013) · The International Journal of Prosthodontics · doi:10.11607/ijp.3229 · Cited by 226 · cited 2×
“This successful result corresponds with the other previous investigations on the zirconia abutments located in the anterior and premolar regions, irrelatively external- or internal implant/abutment connections [66,73,89,90,93,96].”
BackgroundResult(2009) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(09)60140-2 · Cited by 199
Zembic, A., Bösch, A., Jung, R. E., Hämmerle, C. H. F., & Sailer, I. (2013) · Clinical Oral Implants Research · doi:10.1111/clr.12044 · Cited by 183 · cited 3×
“Zembic [73] Prospective 20 Anteriors, premolars Single crown External 1 5.”
BackgroundResultÖrtorp, A., Kihl, M. L., & Carlsson, G. E. (2012) · Journal of Dentistry · doi:10.1016/j.jdent.2012.02.011 · Cited by 151 · cited 1×
“1– 6%) than for alloy–ceramic crowns [91,97,105].”
van Brakel, R., Cune, M. S., Winkelhoff, A. J. V., de Putter, C., Verhoeven, J. W., & van der Reijden, W. A. (2010) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2010.02005.x · Cited by 140 · cited 1×
“ference in peri-implant mucosal discoloration between the two materials was not noticeable to the human eye when the mucosal peri-implant soft tissue thickness exceeded 2 mm [80].”
BackgroundClinical assessment of enamel wear caused by monolithic zirconia crowns
Stober, T., Bermejo, J. L., Schwindling, F. S., & Schmitter, M. (2016) · Journal of Oral Rehabilitation · doi:10.1111/joor.12409 · Cited by 127 · cited 1×
“rates on the opposing natural dentition [122].”
Oliva, J. D., Oliva, X., & Oliva, J. D. (2010) · PubMed · Cited by 119
Fracture rate of monolithic zirconia restorations up to 5 years: A dental laboratory survey
Sulaiman, T. A., Abdulmajeed, A. A., Donovan, T. E., Cooper, L. F., & Walter, R. (2016) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2016.01.033 · Cited by 112 · cited 1×
“09% fracture rate over the 5-year period of the study [111].”
BackgroundCurrent Findings Regarding Zirconia Implants
Depprich, R. A., Naujoks, C. D., Ommerborn, M. A., Schwarz, F., Kübler, N. R., & Handschel, J. G. (2012) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2012.00454.x · Cited by 107 · cited 1×
“Zirconia promoted the attachment of human gingival fibroblasts in vivo, which is desirable because it mimics tooth cementum’s ability to attach to gingiva, forming the junctional epithelium [32].”
BackgroundA retrospective analysis of 102 zirconia single crowns with knife-edge margins
Poggio, C. E., Dosoli, R., & Ercoli, C. (2012) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(12)60083-3 · Cited by 101
Hosseini, M., Worsaae, N., Schiødt, M., & Gotfredsen, K. (2012) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2012.02514.x · Cited by 100
Zirconia abutments and restorations: From laboratory to clinical investigations
Ferrari, M., Vichi, A., & Zarone, F. (2015) · Dental Materials · doi:10.1016/j.dental.2014.11.015 · Cited by 98 · cited 1×
“0 mm of the wall thickness has been advised in these interface areas to provide the adequate mechanical strength necessary to resist physiological chewing forces [83,84].”
Backgroundde Albornoz, A. C., Vignoletti, F., Ferrantino, L., Cárdenas, E., Sanctis, M. D., & Sanz, M. (2014) · Journal Of Clinical Periodontology · doi:10.1111/jcpe.12312 · Cited by 92 · cited 1×
“Also, patient satisfaction was equally high in both groups [74].”
BackgroundPjetursson, B. E., Zwahlen, M., & Lang, N. P. (2012) · Journal Of Clinical Periodontology · doi:10.1111/j.1600-051x.2011.01828.x · Cited by 81 · cited 2×
“2 mm bone loss annually thereafter [22,51].”
BackgroundAssessment of human gingival fibroblast interaction with dental implant abutment materials
Rutkūnas, V., Bukelskienė, V., Sabaliauskas, V., Balčiūnas, E., Malinauskas, M., & Baltriukienė, D. (2015) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-015-5481-8 · Cited by 77
de Ávila, É. D., Ávila-Campos, M. J., Vergani, C. E., Spolidório, D. M. P., & Mollo, F. D. A. (2015) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2015.09.016 · Cited by 72 · cited 1×
“Zirconia exhibited decreased anaerobic biofilm formation compared to titanium or bovine enamel [70].”
BackgroundGherlone, E. F., Mandelli, F., Capparè, P., Pantaleo, G., Traini, T., & Ferrini, F. (2014) · Journal of Dentistry · doi:10.1016/j.jdent.2014.06.002 · Cited by 70 · cited 1×
“8%) success rate due to a high veneer porcelain fracture frequency [101].”
BackgroundMonaco, C., Caldari, M., & Scotti, R. (2013) · The International Journal of Prosthodontics · doi:10.11607/ijp.3099 · Cited by 68
Seven-year prospective clinical study on zirconia-based single crowns and fixed dental prostheses
Tartaglia, G. M., Sidoti, E., & Sforza, C. (2014) · Clinical Oral Investigations · doi:10.1007/s00784-014-1330-2 · Cited by 68 · cited 2×
“6% survival rate [105]; the largest retrospective study, with a follow-up of 1132 crowns for a mean duration of 3.”
BackgroundIn vitro performance of zirconia and titanium implant/abutment systems for anterior application
Rosentritt, M., Hagemann, A., Hahnel, S., Behr, M., & Preis, V. (2014) · Journal of Dentistry · doi:10.1016/j.jdent.2014.03.010 · Cited by 68 · cited 1×
“In these studies, two-piece zirconia abutments with titanium elements have exhibited significantly greater fracture strength than the one-piece zirconia abutments [75,86,87].”
BackgroundRoehling, S., Woelfler, H., Hicklin, S., Kniha, H., & Gahlert, M. (2015) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.12323 · Cited by 67 · cited 3×
“3% survival rate over an average of 7 years for a followup [56].”
BackgroundInfluentialSiddiqi, A., Kieser, J. A., Silva, K. D., Thomson, W. M., & Duncan, W. (2013) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.12159 · Cited by 54
Clinical outcomes of zirconia-based implant- and tooth-supported single crowns
Nejatidanesh, F., Moradpoor, H., & Savabi, O. (2015) · Clinical Oral Investigations · doi:10.1007/s00784-015-1479-3 · Cited by 45
Moráguez, O. D., Wiskott, H. W. A., & Scherrer, S. S. (2015) · Clinical Oral Investigations · doi:10.1007/s00784-015-1455-y · Cited by 45
Nkamgueu, E. M., Adnet, J., Bernard, J., Zierold, K., Kilian, L., Jallot, É., Benhayoune, H., & Bonhomme, P. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20001215)52:4<587::aid-jbm2>3.0.co;2-1 · Cited by 44
Pihlaja, J., Näpänkangas, R., & Raustia, A. M. (2014) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2014.03.008 · Cited by 42
Kohal, R., Schwindling, F. S., Bächle, M., & Spies, B. C. (2015) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.33512 · Cited by 41
Guncu, M., Cakan, U., Muhtarogullari, M., & Canay, S. (2015) · International Journal of Prosthodontics · doi:10.11607/ijp.4168 · Cited by 40
Spies, B. C., Patzelt, S. B. M., Vach, K., & Kohal, R. (2015) · Clinical Oral Implants Research · doi:10.1111/clr.12716 · Cited by 32 · cited 1×
“Spies [55] Prospective 53 1 Healed sites Immediate 36 0.”
BackgroundNäpänkangas, R., Pihlaja, J., & Raustia, A. M. (2015) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2014.09.025 · Cited by 29
Monaco, C., Caldari, M., & Scotti, R. (2016) · The International Journal of Prosthodontics · doi:10.11607/ijp.4038 · Cited by 28
Preliminary laboratory evaluation of bicomponent customized zirconia abutments.
Canullo, L., Morgia, P., & Marinotti, F. (2007) · PubMed · Cited by 20
A Digital Approach to Improved Overdentures for the Adolescent Oligodontia Patient
Cooper, L. F., Culp, L., & Luedin, N. (2016) · Journal of Esthetic and Restorative Dentistry · doi:10.1111/jerd.12217 · Cited by 12
Cited by
Current status on lithium disilicate and zirconia: a narrative review
Zarone, F., Di Mauro, M. I., Ausiello, P., Ruggiero, G., & Sorrentino, R. (2019) · BMC Oral Health · doi:10.1186/s12903-019-0838-x · Cited by 448
Kabir, H., Munir, K., Wen, C., & Li, Y. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.09.013 · Cited by 397
Kwak, H., Wang, S., Park, J., Liu, Y., Kim, K. T., Choi, Y., Mo, Y., & Jung, Y. S. (2022) · ACS Energy Letters · doi:10.1021/acsenergylett.2c00438 · Cited by 341
Moghadasi, K., Mohd Isa, M. S., Ariffin, M. A., Mohd jamil, M. Z., Raja, S., Wu, B., Yamani, M., Bin Muhamad, M. R., Yusof, F., Jamaludin, M. F., et al. (2022) · Journal of Materials Research and Technology · doi:10.1016/j.jmrt.2022.01.050 · Cited by 210
Additive manufacturing of zirconia ceramics: a state-of-the-art review
Zhang, X., Wu, X., & Shi, J. (2020) · Journal of Materials Research and Technology · doi:10.1016/j.jmrt.2020.05.131 · Cited by 181
Metadata
- Authors
- Chen, Y.-W., Moussi, J., Drury, J. L., & Wataha, J. C.
- Venue
- Expert Review of Medical Devices
- Publisher
- Informa UK Limited
- Published
- 2016-09-16
- Volume
- 13
- Issue
- 10
- Pages
- 945-963
- ISSN
- 1743-4440 (ISSN-L)
- 1745-2422
- OpenAlex
- W2520478809
- Cited by
- 238
- References
- 54
- FWCI
- 18.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.