In vitro study of the efficacy of acrylic bone cement loaded with supplementary amounts of gentamicin: Effect on mechanical properties, antibiotic release, and biofilm formation
Open accessThe DOI matches its Crossref record.
Abstract
BACKGROUND: Infection remains a severe complication following a total hip replacement. If infection is suspected when revision surgery is being performed, additional gentamicin is often added to the cement on an ad hoc basis in an attempt to reduce the risk of recurrent infection. METHODS AND RESULTS: In this in vitro study, we determined the effect of incorporating additional gentamicin on the mechanical properties of cement. We also determined the degree of gentamicin release from cement, and also the extent to which biofilms of clinical Staphylococcus spp. isolates form on cement in vitro. When gentamicin was added to unloaded cement (1-4 g), there was a significant reduction in the mechanical performance of the loaded cements compared to unloaded cement. A significant increase in gentamicin release from the cement over 72 h was apparent, with the amount of gentamicin released increasing significantly with each additional 1 g of gentamicin added. When overt infection was modeled, the incorporation of additional gentamicin did result in an initial reduction in bacterial colonization, but this beneficial effect was no longer apparent by 72 h, with the clinical strains forming biofilms on the cements despite the release of high levels of gentamicin. INTERPRETATION: Our findings indicate that the addition of large amounts of gentamicin to cement is unlikely to eradicate bacteria present as a result of an overt infection of an existing implant, and could result in failure of the prosthetic joint because of a reduction in mechanical performance of the bone cement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Scenery of Staphylococcus Implant Infections in Orthopedics
Montanaro, L., Speziale, P., Campoccia, D., Ravaioli, S., Cangini, I., Pietrocola, G., Giannini, S., & Arciola, C. R. (2011) · Future Microbiology · doi:10.2217/fmb.11.117 · Cited by 368
Tan, H., Peng, Z., Li, Q., Xu, X., Guo, S., & Tang, T. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2011.09.084 · Cited by 223
Tan, H., Guo, S., Yang, S., Xu, X., & Tang, T. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.03.013 · Cited by 98
Tan, H.-L., Ao, H.-Y., Ma, R., Lin, W.-T., & Tang, T.-T. (2014) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.03489-14 · Cited by 46
“In vitro studies suggest that up to 8% of the antibiotic in PMMA bone cement is quickly released after surgery, and the low-dose release thereafter may not be effective in fighting infection and may contribute to the problem of antibiotic resistance (8, 9).”
Background
Metadata
- Authors
- Dunne, N., Hill, J., Mcafee, P., Todd, K., Kirkpatrick, R., Tunney, M., & Patrick, S.
- Venue
- Acta Orthopaedica
- Published
- 2007-01
- Volume
- 78
- Issue
- 6
- Pages
- 774-785
- ISSN
- 1745-3674 (ISSN-L)
- 1745-3682
- OpenAlex
- W2017237451
- Cited by
- 98
- References
- 0
- FWCI
- 5.20
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vitro study of the efficacy of acrylic bone cement loaded with supplementary amounts of gentamicin: Effect on mechanical properties, antibiotic release, and biofilm formation. https://app.cochat.ai/papers/10.1080/17453670710014545
- The paper
- Dunne, N., Hill, J., Mcafee, P., Todd, K., Kirkpatrick, R., Tunney, M., & Patrick, S. (2007). In vitro study of the efficacy of acrylic bone cement loaded with supplementary amounts of gentamicin: Effect on mechanical properties, antibiotic release, and biofilm formation. Acta Orthopaedica. https://doi.org/10.1080/17453670710014545
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.