Abstract

PURPOSE: Brain-computer interface (BCI)-controlled assistive robotic systems have been developed with increasing success with the aim to rehabilitation of patients after brain injury to increase independence and quality of life. While such systems may use surgically implanted invasive sensors, non-invasive alternatives can be better suited due to the ease of use, reduced cost, improvements in accuracy and reliability with the advancement of the technology and practicality of use. The consumer-grade BCI devices are often capable of integrating multiple types of signals, including Electroencephalogram (EEG) and Electromyogram (EMG) signals. MATERIALS AND METHODS: This paper summarizes the development of a portable and cost-efficient BCI-controlled assistive technology using a non-invasive BCI headset "OpenBCI" and an open source robotic arm, U-Arm, to accomplish tasks related to rehabilitation, such as access to resources, adaptability or home use. The resulting system used a combination of EEG and EMG sensor readings to control the arm. To avoid risks of injury while the device is being used in clinical settings, appropriate measures were incorporated into the software control of the arm. A short survey was used following the system usability scale (SUS), to measure the usability of the technology to be trialed in clinical settings. RESULTS: From the experimental results, it was found that EMG is a very reliable method for assistive technology control, provided that the user specific EMG calibration is done. With the EEG, even though the results were promising, due to insufficient detection of the signal, the controller was not adequate to be used within a neurorehabilitation environment. The survey indicated that the usability of the system is not a barrier for moving the system into clinical trials.Implication on rehabilitationFor the rehabilitation of patients suffering from neurological disabilities (particularly those suffering from varying degrees of paralysis), it is necessary to develop technology that bypasses the limitations of their condition. For example, if a patient is unable to walk due to the unresponsiveness in their motor neurons, technology can be developed that used an alternate input to move an exoskeleton, which enables the patient to walk again with the assistance of the exoskeleton.This research focuses on neuro-rehabilitation within the framework of the NHS at the Kent and Canterbury Hospital in UK. The hospital currently does not have any system in place for self-driven rehabilitation and instead relies on traditional rehabilitation methods through assistance from physicians and exercise regimens to maintain muscle movement.This paper summarises the development of a portable and cost-efficient BCI controlled assistive technology using a non-invasive BCI headset "OpenBCI" and an open source robotic arm, U-Arm, to accomplish tasks related to rehabilitation, such as access to resources, adaptability or home use. The resulting system used a combination of EEG and EMG sensor readings to control the arm, which could perform a number of different tasks such as picking/placing objects or assist users in eating.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/17483107.2019.1683239

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Research works printed but not linked: 33

  1. King CE, Wang PT, McRimmon CM, et al. The feasibility of a brain-computer interface functional electrical stimulation system for the restoration of overground walking after paraplegia. [updated 2015 Aug; cited 2018 Apr 9]. Available from: https://jneuroengrehab.biomedcentral.com/articles/10.1186/s12984-015-0068-7. · DOI · Paper page
  2. Dokkum LEHV, Ward T, Laffont I. Brain computer interfaces for neurorehabilitation – its current status as a rehabilitation strategy post-stroke. [updated 2015 Feb; cited 2018 Apr 12]. Available from: https://www.ncbi.nlm.nih.gov/pubmed/25614021.
  3. Irimia DC, Poboroniuc MS, Serea F, et al. Controlling a FES-EXOSKELETON Rehabilitation System by Means of Brain-Computer Interface. [updated 2016 Oct; cited 2018 Apr 15]. Available from: https://ieeexplore.ieee.org/document/7781361.
  4. Liberson WT, Holmquest HJ, Scot D, et al. Functional electrotherapy: stimulation of the peroneal nerve synchronized with the swing phase of the gait of hemiplegic patients. [updated 1961 Feb; cited 2018 May 30]. Available from: https://www.ncbi.nlm.nih.gov/pubmed/13761879.
  5. Moe JH, Post HW. Functional electrical stimulation for ambulation in hemiplegia. [updated 1962 Jul; cited 2018 May 30]. Available from: https://www.ncbi.nlm.nih.gov/pubmed/14474974.
  6. Do AH, Wang PT, King CE, et al. Brain-computer interface controlled functional electrical stimulation system for ankle movement. [cited 2018 Apr 24]. Available from: https://jneuroengrehab.biomedcentral.com/track/pdf/10.1186/1743-0003-8-49. · DOI
  7. Badia SB, Morgade AG, Samaha H, et al. Using a hybrid brain computer interface and virtual reality system to monitor and promote cortical reorganization through motor activity and motor imagery training. [updated 2012 Nov; cited 2018 Apr 24]. Available from: https://ieeexplore.ieee.org/abstract/document/6363609.
  8. Pietro C, Silvia S, Federica P, et al. NeuroVirtual 3D: a multiplatform 3D simulation system for application in psychology and neuro-rehabilitation. [updated 2014 Apr; cited 2018 Apr 24]. Available from: https://link.springer.com/chapter/10.1007%2F978-3-642-54816-1_15. · DOI
  9. Ruiz AF, Arturo FC, Rocon E, et al. Exoskeletons for rehabilitation and motor control. [updated 2006 Feb; cited 2018 Apr 24]. Available from: https://ieeexplore.ieee.org/abstract/document/1639155.
  10. Cooley JW, Tukey JW. An algorithm for the machine calculation of complex fourier series. Mathematics of computation, Vol. 19, No. 90. [updated 1965 Apr; cited 2018 Jun 4]. Available from: https://www.jstor.org/stable/2003354?seq=1#page_scan_tab_contents. · DOI · Paper page
  11. Cochran WT, Cooley JW, Favin DL, et al. What is the fast fourier transform. Proceedings of the IEEE, Vol. 55, No. 10, pp. 1664-1674. [updated 1967 Oct · DOI · Paper page
  12. cited 2018 Jun 4]. Available from: https://ieeexplore.ieee.org/document/1447887.
  13. Al-Fahoum AS, Al-Fraihat AA. Methods of EEG signal features extraction using linear analysis in frequency and time-frequency domains. ISRN neuroscience. [updated 2014; cited 2018 Jun 4]. Available from: https://www.hindawi.com/journals/isrn/2014/730218. · DOI · Paper page
  14. Solomon. PSD computations using Welch’s method. [updated 1991; cited 2018 Jun 4]. Available from: https://www.osti.gov/servlets/purl/5688766.
  15. 10.1109/18.57199 · DOI · Paper page
  16. 10.1016/S0925-2312(01)00648-8 · DOI
  17. Prochazka , J Kukal, O. Vysata Wavelet transform use for feature extraction and EEG signal segments classification. Proceedings of the 3rd international symposium on communications, control and signal processing (ISCCSP '08), pp. 719-722. [updated 2008 Mar · DOI
  18. cited 2018 Jun 10]. Available from: https://ieeexplore.ieee.org/document/4537317.
  19. 10.1049/ip-f-1.1988.0022 · doi:10.1049/ip-f-1.1988.0022
  20. Awang SA, 2012, Proceedings of the IEEE EMBS Conference on Biomedical Engineering and Sciences (IECBES ‘12), 778, 10.1109/IECBES.2012.6498164 · doi:10.1109/iecbes.2012.6498164
  21. 10.1016/j.dsp.2008.07.007 · DOI
  22. 10.1016/j.compbiomed.2007.06.002 · DOI
  23. 10.1155/2013/618649 · DOI · Paper page
  24. Li M, Zhang M, Luo X, et al. Combined long short-term memory based network employing wavelet coefficients for MI-EEG Recognition. Proceedings of the 2016 IEEE international conference on mechatronics and automation (ICMA ‘16). [updated 2016 Aug; cited 2018 Jun 112]. Available from: https://ieeexplore.ieee.org/document/7558868. · DOI
  25. 10.1016/j.patrec.2017.05.020 · DOI
  26. 10.1038/2031155a0 · DOI · Paper page
  27. 10.3389/fneng.2012.00014 · DOI · Paper page
  28. 10.1177/155005941104200404 · DOI
  29. David R., 1972, Evoked potentials in psychology, sensory physiology and clinical medicine
  30. 10.1097/00004691-199104000-00007 · DOI · Paper page
  31. Kuo FF, 1966, System analysis by digital computer
  32. Butterworth S., 1930, Experimental Wireless and Wireless Engineer, 7, 536
  33. 10.1007/BF00116251 · DOI · Paper page

Cited by

See all 42

Metadata

Authors
Casey, A., Azhar, H., Grzes, M., & Sakel, M.
Venue
Disability and Rehabilitation: Assistive Technology
Published
2019-11-11
Volume
16
Issue
5
Pages
525-537
ISSN
  • 1748-3107 (ISSN-L)
  • 1748-3115
OpenAlex
W2773950431
Cited by
42
References
4
FWCI
2.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: BCI controlled robotic arm as assistance to the rehabilitation of neurologically disabled patients. https://app.cochat.ai/papers/10.1080/17483107.2019.1683239
The paper
Casey, A., Azhar, H., Grzes, M., & Sakel, M. (2021). BCI controlled robotic arm as assistance to the rehabilitation of neurologically disabled patients. Disability and Rehabilitation: Assistive Technology. https://doi.org/10.1080/17483107.2019.1683239

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.