Active cool roof effect: impact of cool roofs on cooling system efficiency
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Cool roofs represent an acknowledged, relatively simple, and low-cost strategy to reduce cooling energy demand of buildings and mitigate urban heat island phenomena. The purpose of this paper is to study the coupled passive–active effect produced by such a technology, where the active effect consists of the cool roof capability to decrease the suction air temperature of heat pump external units, when these units are located over the roof. This “cooling” benefit produces an extra increase of the energy performance of the heat pump in cooling mode, given that it produces the decrease of the temperature lift between the source and the output. In order to study this twofold effect, an industrial building with an office area located in Rome, Italy, was continuously monitored in summer 2012. The main results showed that the cool roof allows to decrease the roof overheating up to 20°C. The office indoor air temperature also decreased, even if the same set-point temperature was kept constant during the whole campaign. The energy requirement for cooling decreased by about 34%. In order to investigate the “active” contribution, suction air temperature was monitored and a new simple analytical model is proposed in order to estimate the cool roof active effect.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Santamouris, M., Synnefa, A., & Karlessi, T. (2011) · Solar Energy · doi:10.1016/j.solener.2010.12.023 · Cited by 970 · cited 1×
“In order to be able to apply such a technique to existing buildings located in urban area, new less impacting strategies (Pisello, Bobker, & Cotana, 2012; Xu, Taylor, & Pisello, 2014) and materials and roof elements were developed, where infrared reflectance is optimized, but visible aspect is maintained as traditiona…”
BackgroundSelf-citationSynnefa, A., Santamouris, M., & Akbari, H. (2007) · Energy and Buildings · doi:10.1016/j.enbuild.2007.01.004 · Cited by 566
Self-citationCool roof technology in London: An experimental and modelling study
Kolokotroni, M., Gowreesunker, B. L., & Giridharan, R. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2011.07.011 · Cited by 191 · cited 1×
“For instance, Kolokotroni, Gowreesunker, and Giridharan (2013) investigated the effect of a cool roof coating applied on the roof of a naturally ventilated office building in London.”
BackgroundSynnefa, A., Saliari, M., & Santamouris, M. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.01.044 · Cited by 186 · cited 1×
“The effect of cool roofs in determining cooling load and thermal comfort conditions was investigated by Synnefa, Saliari, and Santamouris (2012) for residential buildings.”
Self-citationCool materials and cool roofs: Potentialities in Mediterranean buildings
Zinzi, M. (2010) · Advances in Building Energy Research · doi:10.3763/aber.2009.0407 · Cited by 64 · cited 2×
“In this view, cool roofs represent an interesting passive cooling technique aimed at reducing building energy requirement for cooling (Zinzi, 2010).”
BackgroundInfluential
Research works printed but not linked: 13
- 10.3763/aber.2008.0201 · DOI · Paper page
- 10.1016/j.energy.2011.11.009 · DOI
- 10.1016/j.buildenv.2012.08.013 · DOI
- 10.1080/17512549.2012.672003 · DOI
- 10.1016/j.applthermaleng.2013.05.032 · DOI
- 10.3390/en5125257 · DOI
- 10.1016/j.enbuild.2013.10.031 · DOI · Paper page
- 10.3390/en6083637 · DOI
- 10.1016/j.buildenv.2012.06.017 · DOI
- 10.1016/j.enbuild.2011.07.023 · DOI · Paper page
- 10.1016/j.enbuild.2011.11.051 · DOI
- 10.1016/j.enbuild.2013.09.017 · DOI
- 10.1016/j.enbuild.2012.09.013 · DOI
Cited by
Review on the impact of urban geometry and pedestrian level greening on outdoor thermal comfort
Jamei, E., Rajagopalan, P., Seyedmahmoudian, M., & Jamei, Y. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.10.104 · Cited by 587
LOCAL CLIMATE CHANGE AND URBAN HEAT ISLAND MITIGATION TECHNIQUES – THE STATE OF THE ART
Akbari, H., Cartalis, C., Kolokotsa, D., Muscio, A., Pisello, A. L., Rossi, F., Santamouris, M., Synnef, A., WONG, N. H., & Zinzi, M. (2015) · JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT · doi:10.3846/13923730.2015.1111934 · Cited by 513
Self-citationState of the art on the development of cool coatings for buildings and cities
Pisello, A. L. (2017) · Solar Energy · doi:10.1016/j.solener.2017.01.068 · Cited by 272
Self-citationA study on the comparative review of cool roof thermal performance in various regions
Rawat, M., & Singh, R. N. (2022) · Energy and Built Environment · doi:10.1016/j.enbenv.2021.03.001 · Cited by 197
Dabaieh, M., Wanas, O., Hegazy, M. A., & Johansson, E. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2014.12.034 · Cited by 190
“Consequently, a cool roof reduces energy bills by reducing the dependency on mechanical air conditioning systems [20].”
Background
Metadata
- Authors
- Pisello, A. L., Santamouris, M., & Cotana, F.
- Venue
- Advances in Building Energy Research
- Publisher
- Informa UK Limited
- Published
- 2013-10
- Volume
- 7
- Issue
- 2
- Pages
- 209-221
- ISSN
- 1751-2549 (ISSN-L)
- 1756-2201
- OpenAlex
- W2021749134
- Cited by
- 86
- References
- 5
- FWCI
- 16.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Active cool roof effect: impact of cool roofs on cooling system efficiency. https://app.cochat.ai/papers/10.1080/17512549.2013.865560
- The paper
- Pisello, A. L., Santamouris, M., & Cotana, F. (2013). Active cool roof effect: impact of cool roofs on cooling system efficiency. Advances in Building Energy Research. https://doi.org/10.1080/17512549.2013.865560
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.