The DOI matches its Crossref record.
A general methodology for optimal load management with distributed renewable energy generation and storage in residential housing
Open accessAbstract
In the US, buildings represent around 40% of the primary energy consumption and 74% of the electrical energy consumption [U.S. Department of Energy (DOE). 2012. 2011 Buildings Energy Data Book. Energy Efficiency & Renewable Energy]. Incentives to promote the installation of on-site renewable energy sources have emerged in different states, including net metering programmes. The fast spread of such distributed power generation represents additional challenges for the management of the electricity grid and has led to increased interest in smart control of building loads and demand response programmes. This paper presents a general methodology for assessing opportunities associated with optimal load management in response to evolving utility incentives for residential buildings that employ renewable energy sources and energy storage. An optimal control problem is formulated for manipulating thermostatically controlled domestic loads and energy storage in response to the availability of renewable energy generation and utility net metering incentives. The methodology is demonstrated for a typical American house built in the 1990s and equipped with a single-speed air-to-air heat pump, an electric water heater and photovoltaic (PV) collectors. The additional potential associated with utilizing electrical batteries is also considered. Load matching performance for on-site renewable energy generation is characterized in terms of percentage of the electricity production consumed on-site and the proportion of the demand covered. For the purpose of assessing potential, simulations were performed assuming perfect predictions of the electrical load profiles. The method also allows determination of the optimal size of PV systems for a given net metering programme. Results of the case study showed significant benefits associated with control optimization including an increase of load matching between 3% and 28%, with the improvement dependent on the net metering tariff and available storage capacity. The estimated cost savings for the consumer ranged from 6.4% to 27.5% compared to no optimization with a unitary buy-back ratio, depending on the available storage capacity. Related reduction in CO2 emissions were between 11% and 46%. Optimal load management of the home thermal systems allowed an increase in the optimal size of the PV system in the range of 13–21%.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Moreover, for buildings equipped with on-site generation, the use of thermal storage combined with specific net-metering programs can promote better load matching between production and consumption [197].”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [197]
In the citing paper
“Finally, the desiccant cooling system works near atmospheric pressure, which makes them easy to construct, install, preserve and maintain.”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [198]
In the citing paper
“Desiccant cooling systems were developed to handle sensible and latent heat loads independently [198].”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [198]
In the citing paper
“The system uses eco-friendly fluids including air and water, which have no negative impact on the environment.”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [198]
In the citing paper
“The required electrical energy can be less than 25 % of conventional refrigeration systems and this technique acts as an energy-efficient method, especially for hot dry and hot humid areas.”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [198]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 11
- 10.1016/j.apenergy.2011.12.098 · DOI
- 10.1002/9781118029039 · DOI
- Brandemuehl M. J., 1993, HVAC 2 Toolkit: A Toolkit for Secondary HVAC System Energy Calculations
- 10.1016/j.solener.2011.06.028 · DOI
- 10.1016/j.enbuild.2013.10.019 · DOI · Paper page
- 10.1080/19401493.2013.801518 · DOI
- Ljung L., 1987, Book Title: System Identification – Theory for the User
- 10.1002/ente.201300087 · DOI
- 10.1016/j.apenergy.2008.10.001 · DOI
- 10.1016/j.enbuild.2012.01.032 · DOI
- 10.1016/j.solener.2009.07.007 · DOI
Cited by
Sorted by citations
Resilient cooling strategies – A critical review and qualitative assessment
Zhang, C., Kazanci, O. B., Levinson, R., Heiselberg, P., Olesen, B. W., Chiesa, G., Sodagar, B., Ai, Z., Selkowitz, S., Zinzi, M., et al. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111312 · Cited by 180
Self-citation
Metadata
- Authors
- Georges, E., Braun, J. E., & Lemort, V.
- Affiliations
- University of Liège (BE)
- Purdue University West Lafayette (US)
- Corresponding author
- Georges, E.
- Venue
- Journal of Building Performance Simulation
- Publisher
- Informa UK Limited
- Published
- 2016-08-03
- Volume
- 10
- Issue
- 2
- Pages
- 224-241
- ISSN
- 1940-1493 (ISSN-L)
- 1940-1507
- OpenAlex
- W2494421741
- Cited by
- 20
- References
- 0
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 3 · 2023: 2 · 2022: 2 · 2021: 2 · 2020: 1 · 2019: 4 · 2018: 1 · 2017: 2
- FWCI
- 1.08
- Type
- journal article
- Language
- en
- Open access
- green
- orbi.uliege.be
- Licence
- other-oa
- Locations
- Journal of Building Performance Simulation (publishedVersion)
- Open Repository and Bibliography (University of Liège) (submittedVersion, other-oa)
- Funders
- Lawrence Berkeley National Laboratory (7225563)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Smart Grid Energy Management
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Integrated Energy Systems Optimization
- Keywords
- distributed renewable energy generation, energy storage, residential buildings, net metering, demand response, thermostatically controlled loads, photovoltaic system sizing, battery energy storage, heat pumps, electric water heaters, load matching, optimal control, CO2 emission reduction, smart home control
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review