Building optimization testing framework (BOPTEST) for simulation-based benchmarking of control strategies in buildings
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Development of new building HVAC control algorithms has grown due to needs for energy efficiency and operational flexibility. However, case studies demonstrating new algorithms are largely individualized, making algorithm performance difficult to compare directly. In addition, the effort and expertise required to implement case studies in real or simulated buildings limits rapid prototyping potential. Therefore, this paper presents the Building Optimization Testing Framework (BOPTEST) and associated software for simulation-based benchmarking of building HVAC control algorithms. A containerized run-time environment (RTE) enables rapid, repeatable deployment of common building emulators representing different system types. Emulators use Modelica to represent realistic physical dynamics, embed baseline control, and enable overwriting supervisory and local-loop control signals. Finally, a common set of key performance indicators are calculated within the RTE and reported to the user. This paper details the design and implementation of software and demonstrates its usage to benchmark a Model Predictive Control strategy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
null (2016) · Philosophy Study · doi:10.17265/2159-5313/2016.09.003 · Cited by 28,317
All you need to know about model predictive control for buildings
Drgoňa, J., Arroyo, J., Cupeiro Figueroa, I., Blum, D., Arendt, K., Kim, D., Ollé, E. P., Oravec, J., Wetter, M., Vrabie, D. L., et al. (2020) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2020.09.001 · Cited by 1,020
Self-citationReinforcement learning for demand response: A review of algorithms and modeling techniques
Vázquez-Canteli, J. R., & Nagy, Z. (2019) · Applied Energy · doi:10.1016/j.apenergy.2018.11.002 · Cited by 883
Cited by
Reinforced model predictive control (RL-MPC) for building energy management
Arroyo, J., Manna, C., Spiessens, F., & Helsen, L. (2022) · Applied Energy · doi:10.1016/j.apenergy.2021.118346 · Cited by 249
Self-citationReinforcement learning for HVAC control in intelligent buildings: A technical and conceptual review
Al Sayed, K., Boodi, A., Sadeghian Broujeny, R., & Beddiar, K. (2024) · Journal of Building Engineering · doi:10.1016/j.jobe.2024.110085 · Cited by 140
Evaluation of advanced control strategies for building energy systems
Stoffel, P., Maier, L., Kümpel, A., Schreiber, T., & Müller, D. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2022.112709 · Cited by 126
“Here, we see great potential in utilizing the BOPTEST framework as it provides standardized benchmarks and performance measures [90].”
Machine Learning for Smart and Energy-Efficient Buildings
Das, H. P., Lin, Y.-W., Agwan, U., Spangher, L., Devonport, A., Yang, Y., Drgoňa, J., Chong, A., Schiavon, S., & Spanos, C. J. (2024) · Environmental Data Science · doi:10.1017/eds.2023.43 · Cited by 78
Self-citation
Metadata
- Authors
- Blum, D., Arroyo, J., Huang, S., Drgoňa, J., Jorissen, F., Walnum, H. T., Chen, Y., Benne, K., Vrabie, D., Wetter, M., & Helsen, L.
- Venue
- Journal of Building Performance Simulation
- Publisher
- Informa UK Limited
- Published
- 2021-09-03
- Volume
- 14
- Issue
- 5
- Pages
- 586-610
- ISSN
- 1940-1493 (ISSN-L)
- 1940-1507
- OpenAlex
- W3209188603
- Cited by
- 225
- References
- 3
- FWCI
- 10.43
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.