The use of natural zeolite to remove heavy metals Cu (II), Pb (II) and Cd (II), from industrial wastewater

Open access
Elboughdiri, Noureddine · 2020 · Cogent Engineering
Cited by 163

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

In this study, the adsorption behavior of Cu2+, Pb2+ and Cd2+ from synthetic metal solutions using natural zeolites was studied in order to investigate the efficiency of adsorbents of heavy metals from industrial wastewater. The kinetic study indicated the suitability of the zeolite for the removal of Cu2+, Pb2+ and Cd2+ ions from synthetic wastewater; batch experiments were used to identify the effect of parameters that affect the rate of adsorption such as the adsorbent mass, the initial solution concentration, the initial solution pH, the adsorbent particle size, and the agitation speed and evaluated their impact on the removal efficiency of heavy metals from industrial wastewater using the natural zeolite. Zeolite samples with masses between 1 g and 10 g were contacted with constant volume (100 ml) of multicomponent synthetic solutions containing Cu2+, Pb2+ and Cd2+ ions. They were agitated at agitation speeds in the range of 100–300 rpm for agitation times from 1 hr to 8 hrs in a magnetic stirrer at room temperature, the pH values were monitored and adjusted regularly. Every hour, 15 ml of the samples was analyzed using the Atomic Absorption Spectroscopy. The results show that the removal efficiency of Cu2+ increase from 60% for 1 gr to 99% for 10 gr of the mass of absorbent, increase from 62% for 1% to 94% for 7 of the initial solution pH, increase from 90% for 100 rpm to 94% for 300 rpm of the agitation speed, the amount adsorbed increase from 0.5 mg/g for 100 mg/l to 2.1% for 400 mg/l of the initial solution concentration. Similar results are obtained for the two other heavy metals (Pb2+, Cd2+) and showed that the capacity of the adsorbents for the removal of heavy metals is directly proportional to the mass of absorbent, initial solution pH, agitation speed, and initial solution concentration. The highest adsorption rate of Cu2+, Pb2+ and Cd2+ ions took place in the first hours followed by a slower adsorption rate later on.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/23311916.2020.1782623

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 163

Metadata

Authors
Elboughdiri, N.
Venue
Cogent Engineering
Published
2020-01
Volume
7
Issue
1
ISSN
2331-1916 (ISSN-L)
OpenAlex
W3037783611
Cited by
163
References
4
FWCI
6.66
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The use of natural zeolite to remove heavy metals Cu (II), Pb (II) and Cd (II), from industrial wastewater. https://app.cochat.ai/papers/10.1080/23311916.2020.1782623
The paper
Elboughdiri, N. (2020). The use of natural zeolite to remove heavy metals Cu (II), Pb (II) and Cd (II), from industrial wastewater. Cogent Engineering. https://doi.org/10.1080/23311916.2020.1782623

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.