Arterio-venous anastomoses in the human skin and their role in temperature control
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Arterio-venous anastomoses (AVAs) are direct connections between small arteries and small veins. In humans they are numerous in the glabrous skin of the hands and feet. The AVAs are short vessel segments with a large inner diameter and a very thick muscular wall. They are densely innervated by adrenergic axons. When they are open, they provide a low-resistance connection between arteries and veins, shunting blood directly into the venous plexuses of the limbs. The AVAs play an important role in temperature regulation in humans in their thermoneutral zone, which for a naked resting human is about 26°C to 36°C, but lower when active and clothed. From the temperature control center in the hypothalamus, bursts of nerve impulses are sent simultaneously to all AVAs. The AVAs are all closed near the lower end and all open near the upper end of the thermoneutral zone. The small veins in the skin of the arms and legs are also contracted near the lower end of the thermoneutral zone and relax to a wider cross section as the ambient temperature rises. At the cold end of the thermoneutral range, the blood returns to the heart through the deep veins and cools the arterial blood through a countercurrent mechanism. As the ambient temperature rises, more blood is returned through the superficial venous plexuses and veins and heats the skin surface of the full length of the 4 limbs. This skin surface is responsible for a large part of the loss of heat from the body toward the upper end of the thermoneutral zone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Burton, A. C. (1939) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1939.127.3.437 · Cited by 333 · cited 1×
“The first physiological blood flow measurements which could be related to the opening and closing of AVAs in humans were obtained by Burton using a finger plethysmograph.(13) He showed that successive”
Method
Cited by
The thermoregulation system and how it works
(2018) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-63912-7.00001-1 · Cited by 186
Thermal comfort of heterogeneous and dynamic indoor conditions — An overview
Mishra, A. K., Loomans, M. G. L. C., & Hensen, J. L. M. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.09.016 · Cited by 167
Metadata
- Authors
- Walløe, L.
- Venue
- Temperature
- Publisher
- Informa UK Limited
- Published
- 2015-10-12
- Volume
- 3
- Issue
- 1
- Pages
- 92-103
- ISSN
- 2332-8940 (ISSN-L)
- 2332-8959
- OpenAlex
- W2249098330
- Cited by
- 189
- References
- 1
- FWCI
- 5.38
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Arterio-venous anastomoses in the human skin and their role in temperature control. https://app.cochat.ai/papers/10.1080/23328940.2015.1088502
- The paper
- Walløe, L. (2016). Arterio-venous anastomoses in the human skin and their role in temperature control. Temperature. https://doi.org/10.1080/23328940.2015.1088502
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.