A review of fault detection and diagnostics methods for building systems
The DOI matches its Crossref record; 79 of the 79 references it cites were found in a registry or an index.
Abstract
The current article provides a summary of automated fault detection and diagnostics studies published since 2004 that are relevant to the commercial buildings sector. The review updates a previous review conducted in 2004 and published in 2005, and it categorizes automated fault detection and diagnostics methods into three groups. The examples of automated fault detection and diagnostics in the primary category are selectively reviewed to identify various methods that are suitable for building systems and to understand the strengths and weaknesses of the methods. The distribution of studies based on each automated fault detection and diagnostics method and heating, ventilation, and air-conditioning system is also described. Researchers and industries can use the current article as a guideline for selecting an appropriate automated fault detection and diagnostics method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Katipamula, S., & Brambley, M. R. (2005) · HVAC&R Research · doi:10.1080/10789669.2005.10391123 · Cited by 936
Self-citationBuilding operation and energy performance: Monitoring, analysis and optimisation toolkit
Costa, A., Keane, M. M., Torrens, J. I., & Corry, E. (2013) · Applied Energy · doi:10.1016/j.apenergy.2011.10.037 · Cited by 394
A rule-based fault detection method for air handling units
Schein, J., Bushby, S. T., Castro, N. S., & House, J. M. (2006) · Energy and Buildings · doi:10.1016/j.enbuild.2006.04.014 · Cited by 372
Katipamula, S., & Brambley, M. R. (2005) · HVAC&R Research · doi:10.1080/10789669.2005.10391133 · Cited by 306
Self-citationDu, Z., Fan, B., Jin, X., & Chi, J. (2014) · Building and Environment · doi:10.1016/j.buildenv.2013.11.021 · Cited by 296
AHU sensor fault diagnosis using principal component analysis method
Wang, S., & Xiao, F. (2003) · Energy and Buildings · doi:10.1016/j.enbuild.2003.10.002 · Cited by 258
Model-based Fault Detection and Diagnosis of HVAC systems using Support Vector Machine method
Liang, J., & Du, R. (2007) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2006.12.012 · Cited by 248
A model-based fault detection and diagnostic methodology based on PCA method and wavelet transform
Li, S., & Wen, J. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2013.08.044 · Cited by 244
Lee, W.-Y., House, J. M., & Kyong, N.-H. (2003) · Applied Energy · doi:10.1016/s0306-2619(03)00107-7 · Cited by 199
Fault detection analysis using data mining techniques for a cluster of smart office buildings
Capozzoli, A., Lauro, F., & Khan, I. (2015) · Expert Systems with Applications · doi:10.1016/j.eswa.2015.01.010 · Cited by 195
Cited by
A review of machine learning in building load prediction
Zhang, L., Wen, J., Li, Y., Chen, J., Ye, Y., Fu, Y., & Livingood, W. (2021) · Applied Energy · doi:10.1016/j.apenergy.2021.116452 · Cited by 671
Zhao, Y., Li, T., Zhang, X., & Zhang, C. (2019) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.04.021 · Cited by 594
O’Dwyer, E., Pan, I., Acha, S., & Shah, N. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.01.024 · Cited by 410
Mirnaghi, M. S., & Haghighat, F. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.110492 · Cited by 387
A review of smart building sensing system for better indoor environment control
Dong, B., Prakash, V., Feng, F., & O'Neill, Z. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2019.06.025 · Cited by 360
Pinto, G., Wang, Z., Roy, A., Hong, T., & Capozzoli, A. (2022) · Advances in Applied Energy · doi:10.1016/j.adapen.2022.100084 · Cited by 295
Awada, M., Becerik-Gerber, B., Hoque, S., O'Neill, Z., Pedrielli, G., Wen, J., & Wu, T. (2021) · Building and Environment · doi:10.1016/j.buildenv.2020.107480 · Cited by 262
Early detection of faults in HVAC systems using an XGBoost model with a dynamic threshold
Chakraborty, D., & Elzarka, H. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2018.12.032 · Cited by 169
Semi-supervised learning for early detection and diagnosis of various air handling unit faults
Yan, K., Zhong, C., Ji, Z., & Huang, J. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.10.016 · Cited by 167
“Support Vector Machine and Its Extensions Support vector machine (SVM) is one of the most commonly used machine learning techniques for small to medium size data classification problems and has been applied to FDD approaches for HVAC subsystems in existing stateof-art works [4, 7, 8].”
MethodText-mining building maintenance work orders for component fault frequency
Gunay, H. B., Shen, W., & Yang, C. (2019) · Building Research & Information · doi:10.1080/09613218.2018.1459004 · Cited by 112
Bellanco, I., Fuentes, E., Vallès, M., & Salom, J. (2021) · Journal of Building Engineering · doi:10.1016/j.jobe.2021.102254 · Cited by 84
Metadata
- Authors
- Kim, W., & Katipamula, S.
- Venue
- Science and Technology for the Built Environment
- Publisher
- Informa UK Limited
- Published
- 2017-05-08
- Volume
- 24
- Issue
- 1
- Pages
- 3-21
- ISSN
- 1078-9669 (ISSN-L)
- 2374-4731
- 2374-474X
- OpenAlex
- W2607521821
- Cited by
- 384
- References
- 79
- FWCI
- 33.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.