The DOI matches its Crossref record.
Intrapartum ultrasound for the examination of the fetal head position in normal and obstructed labor
Abstract
OBJECTIVE: To assess the feasibility of transabdominal ultrasound for determining fetal head position in laboring women and compare it to digital examination, and to study ultrasonographically the rotation of the fetal head in normal and obstructed labor. DESIGN: This was an observational prospective study of 148 women in active labor. Ultrasound examinations were performed longitudinally in the first and second stages of labor. RESULTS: Assessment of the fetal head position by digital examination was not possible in 60.7% (122/201) of cases in the first stage and 30.8% (41/133) in the second stage of labor. Difficulty in assessing the position was more likely if the occiput was posterior in comparison to anterior and in the maternal right in comparison to the left side. In the second stage, it was three times more likely for the assessment not to be possible digitally if the occiput was posterior. In the cases when assessment by vaginal examination was possible, the correlation with ultrasound was average in the first stage (kappa = 0.59) and good in the second stage (kappa = 0.77). Overall fetal head position assessment by digital examination was accurate in 31.28% of the cases in the first stage and 65.7% of the cases in the second stage of labor. Rotation of the fetal head is highly unlikely when labor begins in the occipital anterior position. Persistent occipital posterior position developed through failure to rotate from an initial occipital posterior or transverse position. Duration of the first stage of labor was independently related to parity and position of the fetal spine at presentation, and duration of the second stage of labor was independently related to parity, birth weight, position of the fetal head at the beginning of the second stage, rotation and position of the head at delivery. CONCLUSION: Ultrasound assessment of the fetal head position in labor is feasible in a busy labor ward. Digital examination is less accurate than ultrasound, in particular in cases of obstructed labor when medical intervention is more likely to be needed. Ultrasound assessment may prove useful in the prediction and diagnosis of difficult and prolonged labor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ISUOG Practice Guidelines: intrapartum ultrasound
Ghi, T., Eggebø, T., Lees, C., Kalache, K., Rozenberg, P., Youssef, A., Salomon, L. J., & Tutschek, B. (2018) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.19072 · Cited by 348
Kalache, K. D., Dückelmann, A. M., Michaelis, S. A. M., Lange, J., Cichon, G., & Dudenhausen, J. W. (2009) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.6294 · Cited by 262
Ghi, T., Conversano, F., Ramirez Zegarra, R., Pisani, P., Dall'Asta, A., Lanzone, A., Lau, W., Vimercati, A., Iliescu, D. G., Mappa, I., et al. (2022) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.23739 · Cited by 32
Metadata
- Authors
- Souka, A. P., Haritos, T., Basayiannis, K., Noikokyri, N., & Antsaklis, A.
- Venue
- The Journal of Maternal-Fetal & Neonatal Medicine
- Publisher
- Informa UK Limited
- Published
- 2003-01-01
- Volume
- 13
- Issue
- 1
- Pages
- 59-63
- ISSN
- 1476-4954 (ISSN-L)
- 1476-7058
- OpenAlex
- W2163698098
- Cited by
- 166
- References
- 0
- FWCI
- 4.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intrapartum ultrasound for the examination of the fetal head position in normal and obstructed labor. https://app.cochat.ai/papers/10.1080/713605747
- The paper
- Souka, A. P., Haritos, T., Basayiannis, K., Noikokyri, N., & Antsaklis, A. (2003). Intrapartum ultrasound for the examination of the fetal head position in normal and obstructed labor. The Journal of Maternal-Fetal & Neonatal Medicine. https://doi.org/10.1080/713605747
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.