Distortion of Femtosecond Laser Pulses in Lenses and Lens Systems
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Owing to the difference between the phase and group velocity, the pulse front may be delayed with respect to the phase front by several picoseconds when traversing a lens or a lens system. The delay is a parabolic function of the input radius. The delay is calculated for singlet lenses, achromats, compound lenses, telescopes. The effect may be two to three orders of magnitude larger than the broadening due to group velocity dispersion in the materials of the lenses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Optics: 60th Anniversary Edition
Born, M., & Wolf, E. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108769914 · Cited by 26,251
Interspecimen Comparison of the Refractive Index of Fused Silica*,†
Malitson, I. H. (1965) · Journal of the Optical Society of America · doi:10.1364/josa.55.001205 · Cited by 4,216
Optical pulse compression with diffraction gratings
Treacy, E. (1969) · IEEE Journal of Quantum Electronics · doi:10.1109/jqe.1969.1076303 · Cited by 1,363
Valdmanis, J. A., Fork, R. L., & Gordon, J. P. (1985) · Optics Letters · doi:10.1364/ol.10.000131 · Cited by 427
A Redetermination of Some Optical Properties of Calcium Fluoride
Malitson, I. H. (1963) · Applied Optics · doi:10.1364/ao.2.001103 · Cited by 371
Negative group-velocity dispersion using refraction
Martinez, O. E., Gordon, J. P., & Fork, R. L. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.001003 · Cited by 358
Valdmanis, J., & Fork, R. (1986) · IEEE Journal of Quantum Electronics · doi:10.1109/jqe.1986.1072854 · Cited by 228
Pulse distortions in tilted pulse schemes for ultrashort pulses
Martinez, O. E. (1986) · Optics Communications · doi:10.1016/0030-4018(86)90290-7 · Cited by 175
Bor, Z., & Rácz, B. (1985) · Optics Communications · doi:10.1016/0030-4018(85)90284-6 · Cited by 175
Self-citationDesign of high-power ultrashort pulse amplifiers by expansion and recompression
Martínez, O. E. (1987) · IEEE Journal of Quantum Electronics · doi:10.1109/jqe.1987.1073518 · Cited by 145
Cited by
Xu, C., & Webb, W. W. (1996) · Journal of the Optical Society of America B · doi:10.1364/josab.13.000481 · Cited by 2,198
The role of dispersion in ultrafast optics
Walmsley, I., Waxer, L., & Dorrer, C. (2001) · Review of Scientific Instruments · doi:10.1063/1.1330575 · Cited by 225
Distortion of femtosecond laser pulses in lenses
Bor, Z. (1989) · Optics Letters · doi:10.1364/ol.14.000119 · Cited by 211
Self-citation
Metadata
- Authors
- Bor, Z.
- Venue
- Journal of Modern Optics
- Publisher
- Informa UK Limited
- Published
- 1988-12
- Volume
- 35
- Issue
- 12
- Pages
- 1907-1918
- ISSN
- 0950-0340 (ISSN-L)
- 1362-3044
- OpenAlex
- W2048398397
- Cited by
- 210
- References
- 11
- FWCI
- 3.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.