A SIMPLE PARAMETER FOR SELECTING AN ADSORBENT FOR GAS SEPARATION BY PRESSURE SWING ADSORPTION
The DOI matches its Crossref record.
Abstract
A simple parameter is proposed for comparing the performance of two or more adsorbents for a particular binary gas separation by pressure swing adsorption. The parameter is most suitable for separations based on differences in equilibrium adsorption capacity rather than on differences in adsorption kinetics. The two main components of the parameter are the ratio of the delta loadings (differences in adsorbed amounts at high and low pressures) of the 2 gases (Δq 1/Δq 2) and the equilibrium selectivity (α1,2) of the sorbent for the strongly adsorbed species. A dimensionless sorbent selection parameter (S) is defined. For a given separation, the sorbent that yields the highest S value is the best sorbent. In the cases of sorbate-sorbent systems showing Langmuir-type isotherms, This parameter is simple to calculate and is sensitive to subtle differences in adsorption isotherms. The effectiveness of the proposed parameter was demonstrated through two examples of air separation using molecular-sieve zeolites.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Development and Evaluation of Porous Materials for Carbon Dioxide Separation and Capture
Bae, Y., & Snurr, R. Q. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201101891 · Cited by 1,208
CO2 Capture and Separations Using MOFs: Computational and Experimental Studies
Yu, J., Xie, L.-H., Li, J.-R., Ma, Y., Seminario, J. M., & Balbuena, P. B. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00626 · Cited by 1,047
Application of natural zeolites in the purification and separation of gases
Ackley, M. (2003) · Microporous and Mesoporous Materials · doi:10.1016/s1387-1811(03)00353-6 · Cited by 494
Natural gas treating by selective adsorption: Material science and chemical engineering interplay
Tagliabue, M., Farrusseng, D., Valencia, S., Aguado, S., Ravon, U., Rizzo, C., Corma, A., & Mirodatos, C. (2009) · Chemical Engineering Journal · doi:10.1016/j.cej.2009.09.010 · Cited by 471
Application of isotherms models and error functions in activated carbon CO2 sorption processes
Serafin, J., & Dziejarski, B. (2023) · Microporous and Mesoporous Materials · doi:10.1016/j.micromeso.2023.112513 · Cited by 268
Metadata
- Authors
- Rege, S., & Yang, R.
- Venue
- Separation Science and Technology
- Publisher
- Informa UK Limited
- Published
- 2001-11-30
- Volume
- 36
- Issue
- 15
- Pages
- 3355-3365
- ISSN
- 0149-6395 (ISSN-L)
- 1520-5754
- OpenAlex
- W2067900833
- Cited by
- 109
- References
- 0
- FWCI
- 2.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A SIMPLE PARAMETER FOR SELECTING AN ADSORBENT FOR GAS SEPARATION BY PRESSURE SWING ADSORPTION. https://app.cochat.ai/papers/10.1081/ss-100107907
- The paper
- Rege, S., & Yang, R. (2001). A SIMPLE PARAMETER FOR SELECTING AN ADSORBENT FOR GAS SEPARATION BY PRESSURE SWING ADSORPTION. Separation Science and Technology. https://doi.org/10.1081/ss-100107907
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.