Fusion of Constitutive Membrane Traffic with the Cell Surface Observed by Evanescent Wave Microscopy
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Monitoring the fusion of constitutive traffic with the plasma membrane has remained largely elusive. Ideally, fusion would be monitored with high spatial and temporal resolution. Recently, total internal reflection (TIR) microscopy was used to study regulated exocytosis of fluorescently labeled chromaffin granules. In this technique, only the bottom cellular surface is illuminated by an exponentially decaying evanescent wave of light. We have used a prism type TIR setup with a penetration depth of ∼50 nm to monitor constitutive fusion of vesicular stomatitis virus glycoprotein tagged with the yellow fluorescent protein. Fusion of single transport containers (TCs) was clearly observed and gave a distinct analytical signature. TCs approached the membrane, appeared to dock, and later rapidly fuse, releasing a bright fluorescent cloud into the membrane. Observation and analysis provided insight about their dynamics, kinetics, and position before and during fusion. Combining TIR and wide-field microscopy allowed us to follow constitutive cargo from the Golgi complex to the cell surface. Our observations include the following: (1) local restrained movement of TCs near the membrane before fusion; (2) apparent anchoring near the cell surface; (3) heterogeneously sized TCs fused either completely; or (4) occasionally larger tubular-vesicular TCs partially fused at their tips.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hirschberg, K., Miller, C. M., Ellenberg, J., Presley, J. F., Siggia, E. D., Phair, R. D., & Lippincott-Schwartz, J. (1998) · The Journal of Cell Biology · doi:10.1083/jcb.143.6.1485 · Cited by 610
Cited by
Studying protein dynamics in living cells
Lippincott-Schwartz, J., Snapp, E., & Kenworthy, A. (2001) · Nature Reviews Molecular Cell Biology · doi:10.1038/35073068 · Cited by 1,190
Total Internal Reflection Fluorescence Microscopy in Cell Biology
Axelrod, D. (2001) · Traffic · doi:10.1034/j.1600-0854.2001.21104.x · Cited by 959
Procollagen trafficking, processing and fibrillogenesis
Canty, E. G., & Kadler, K. E. (2005) · Journal of Cell Science · doi:10.1242/jcs.01731 · Cited by 764
Lang, T. (2001) · The EMBO Journal · doi:10.1093/emboj/20.9.2202 · Cited by 686
Secretory Protein Trafficking and Organelle Dynamics in Living Cells
Lippincott-Schwartz, J., Roberts, T. H., & Hirschberg, K. (2000) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev.cellbio.16.1.557 · Cited by 501
Metadata
- Authors
- Toomre, D., Steyer, J. A., Keller, P., Almers, W., & Simons, K.
- Venue
- The Journal of Cell Biology
- Publisher
- Rockefeller University Press
- Published
- 2000-04-03
- Volume
- 149
- Issue
- 1
- Pages
- 33-40
- ISSN
- 0021-9525 (ISSN-L)
- 1540-8140
- OpenAlex
- W2066584584
- Cited by
- 150
- References
- 1
- FWCI
- 6.28
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fusion of Constitutive Membrane Traffic with the Cell Surface Observed by Evanescent Wave Microscopy. https://app.cochat.ai/papers/10.1083/jcb.149.1.33
- The paper
- Toomre, D., Steyer, J. A., Keller, P., Almers, W., & Simons, K. (2000). Fusion of Constitutive Membrane Traffic with the Cell Surface Observed by Evanescent Wave Microscopy. The Journal of Cell Biology. https://doi.org/10.1083/jcb.149.1.33
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.