The DOI matches its Crossref record.
Conformational changes in CLIP-170 regulate its binding to microtubules and dynactin localization
Open accessAbstract
Cytoplasmic linker protein (CLIP)-170, CLIP-115, and the dynactin subunit p150Glued are structurally related proteins, which associate specifically with the ends of growing microtubules (MTs). Here, we show that down-regulation of CLIP-170 by RNA interference results in a strongly reduced accumulation of dynactin at the MT tips. The NH2 terminus of p150Glued binds directly to the COOH terminus of CLIP-170 through its second metal-binding motif. p150Glued and LIS1, a dynein-associating protein, compete for the interaction with the CLIP-170 COOH terminus, suggesting that LIS1 can act to release dynactin from the MT tips. We also show that the NH2-terminal part of CLIP-170 itself associates with the CLIP-170 COOH terminus through its first metal-binding motif. By using scanning force microscopy and fluorescence resonance energy transfer-based experiments we provide evidence for an intramolecular interaction between the NH2 and COOH termini of CLIP-170. This interaction interferes with the binding of the CLIP-170 to MTs. We propose that conformational changes in CLIP-170 are important for binding to dynactin, LIS1, and the MT tips.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tracking the ends: a dynamic protein network controls the fate of microtubule tips
Akhmanova, A., & Steinmetz, M. O. (2008) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2369 · Cited by 1,047
Self-citationControl of microtubule organization and dynamics: Two ends in the limelight
Akhmanova, A., & Steinmetz, M. O. (2015) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm4084 · Cited by 895
Self-citationTRAK/Milton motor-adaptor proteins steer mitochondrial trafficking to axons and dendrites
van Spronsen, M., Mikhaylova, M., Lipka, J., Schlager, M. A., van den Heuvel, D. J., Kuijpers, M., Wulf, P. S., Keijzer, N., Demmers, J., Kapitein, L. C., et al. (2013) · Neuron · doi:10.1016/j.neuron.2012.11.027 · Cited by 450
Self-citationPeris, L., Thery, M., Fauré, J., Saoudi, Y., Lafanechère, L., Chilton, J. K., Gordon-Weeks, P., Galjart, N., Bornens, M., Wordeman, L., et al. (2006) · The Journal of Cell Biology · doi:10.1083/jcb.200512058 · Cited by 347
Self-citationPowering membrane traffic in endocytosis and recycling
Soldati, T., & Schliwa, M. (2006) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2060 · Cited by 346
Metadata
- Authors
- Lansbergen, G., Komarova, Y., Modesti, M., Wyman, C., Hoogenraad, C. C., Goodson, H. V., Lemaitre, R. P., Drechsel, D. N., van Munster, E., Gadella, T. W. J., Grosveld, F., Galjart, N., Borisy, G. G., & Akhmanova, A.
- Venue
- The Journal of Cell Biology
- Publisher
- Rockefeller University Press
- Published
- 2004-09-20
- Volume
- 166
- Issue
- 7
- Pages
- 1003-1014
- ISSN
- 0021-9525 (ISSN-L)
- 1540-8140
- OpenAlex
- W2167016752
- Cited by
- 178
- References
- 0
- FWCI
- 5.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Conformational changes in CLIP-170 regulate its binding to microtubules and dynactin localization. https://app.cochat.ai/papers/10.1083/jcb.200402082
- The paper
- Lansbergen, G., Komarova, Y., Modesti, M., Wyman, C., Hoogenraad, C. C., Goodson, H. V., Lemaitre, R. P., Drechsel, D. N., van Munster, E., Gadella, T. W. J., Grosveld, F., Galjart, N., Borisy, G. G., & Akhmanova, A. (2004). Conformational changes in CLIP-170 regulate its binding to microtubules and dynactin localization. The Journal of Cell Biology. https://doi.org/10.1083/jcb.200402082
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.