The DOI matches its Crossref record.
THE PERMEABILITY OF GLOMERULAR CAPILLARIES TO GRADED DEXTRANS
Open accessAbstract
Graded dextrans have been used as tracers to identify the primary permeability barrier(s) to macromolecules among the structural elements (endothelium, mesangium, basement membrane, epithelium) of the glomerular capillary wall. Three narrow-range fractions of specified molecular weights and Einstein-Stokes radii (ESR) were prepared by gel filtration: (a) 32,000 mol wt, ESR = 38 Å; (b) 62,000 mol wt, ESR = 55 Å; and (c) 125,000 mol wt, ESR = 78 Å. These fractions are known to be extensively filtered, filtered in only small amounts, and largely retained, respectively, by the glomerular capillaries. Tracer solutions were infused i.v. into Wistar-Furth rats, and the left kidney was fixed after 5 min to 4 h. The preparations behaved as predicted: initially, all three fractions appeared in the urinary spaces, with 32,000 > 62,000 » 125,000. The smallest fraction was totally cleared from the blood and urinary spaces by 2.5 h, whereas the intermediate and largest fractions were retained in the circulation at high concentrations up to 4 h. With all fractions, when particles occurred in high concentration in the capillary lumina, they were present in similarly high concentrations in the endothelial fenestrae and inner (subendothelial) portions of the basement membrane, but there was a sharp drop in their concentration at this level—i.e., between the inner, looser portions of the basement membrane and its outer, more compact portions. With the two largest fractions, accumulation of particles occurred against the basement membrane in the mesangial regions with time. No accumulation was seen with any of the fractions in the epithelial slits or against the slit membranes. Dextran was also seen in phagosomes in mesangial cells, and in absorption droplets in the glomerular and proximal tubule epithelium. It is concluded that the basement membrane is the main glomerular permeability barrier to dextrans, and (since their behavior is known to be similar) to proteins of comparable dimensions (40,000–200,000 mol wt). The findings are discussed in relation to previous work using electron-opaque tracers to localize the glomerular permeability barrier and in relation to models proposed for the functions of the various glomerular structural elements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cell biology of the glomerular podocyte
Pavenstädt, H., Kriz, W., & Kretzler, M. (2003) · Physiological Reviews · doi:10.1152/physrev.00020.2002 · Cited by 1,499
Basement Membranes: Cell Scaffoldings and Signaling Platforms
Yurchenco, P. D. (2011) · Cold Spring Harbor Perspectives in Biology · doi:10.1101/cshperspect.a004911 · Cited by 959
Properties of the Glomerular Barrier and Mechanisms of Proteinuria
Haraldsson, B., Nyström, J., & Deen, W. M. (2008) · Physiological Reviews · doi:10.1152/physrev.00055.2006 · Cited by 909
Yan, L., Borregaard, N., Kjeldsen, L., & Moses, M. A. (2001) · Journal of Biological Chemistry · doi:10.1074/jbc.m106089200 · Cited by 676
Kanwar, Y. S., & Farquhar, M. G. (1979) · The Journal of cell biology · doi:10.1083/jcb.81.1.137 · Cited by 553
Self-citation
Metadata
- Authors
- Caulfield, J. P., & Farquhar, M. G.
- Venue
- The Journal of Cell Biology
- Publisher
- Rockefeller University Press
- Published
- 1974-12-01
- Volume
- 63
- Issue
- 3
- Pages
- 883-903
- ISSN
- 0021-9525 (ISSN-L)
- 1540-8140
- OpenAlex
- W2065377772
- Cited by
- 280
- References
- 0
- FWCI
- 16.40
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: THE PERMEABILITY OF GLOMERULAR CAPILLARIES TO GRADED DEXTRANS. https://app.cochat.ai/papers/10.1083/jcb.63.3.883
- The paper
- Caulfield, J. P., & Farquhar, M. G. (1974). THE PERMEABILITY OF GLOMERULAR CAPILLARIES TO GRADED DEXTRANS. The Journal of Cell Biology. https://doi.org/10.1083/jcb.63.3.883
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.