Cited by 191Genetic and Kidney Cyst DiseasesAdvanced Electron Microscopy Techniques and ApplicationsMicrotubule and mitosis dynamics

Structure and molecular weight of the dynein ATPase

Open access
Johnson, KA, Wall, JS·1983·The Journal of Cell Biology

Abstract

Dynein has been examined by scanning transmission electron microscopy (STEM). Samples of 30S dynein from tetrahymena cilia were applied to carbon films and either were freeze- dried and examined as unstained, unfixed specimens, or were negatively stained with uranyl sulfate. A totally new image of the dynein molecule was revealed showing three globular heads connected by three separate strands to a common base. Two of the heads appeared to be identical and exhibited a diameter of 10 nm while the third head was somewhat larger (approximately 12 nm). The overall length of the particle was 35 nm. Mass analysis, based upon the integration of electron scattering intensities for unstained particles, gave a molecular weight of 1.95 (+/-)0.24) megadaltons. Mass per unit length analysis was performed using bovine brain microtubules decorated with dynein under conditions where the dynein shows a linear repeat of 24 nm with seven dynein molecules surrounding a microtubule made up of 14 protofilaments. Undecorated microtubules gave a molecular weight per unit length of 21,000+/-1,900 daltons/A, compared to a value of 84,400+/-2,200 daltons/A for the fully decorated microtubules. Taken together, these data give a molecular weight of 2.17 (+/- 0.14) megadaltons per dynein molecule, in agreement with measurements on the isolated particles. Mass analysis of individual globular heads observed in isolated particles gave a molecular weight distribution with a mean of 416+/- 76 kdaltons. These data could also be viewed as the sum of two populations of head with two-thirds of the heads at approximately 400 kdaltons and one-third at approximately 550 kdaltons, although more precise data will be required to distinguish two classes of heads with confidence. The mass of the dynein-microtubule complex as a function of distance from the midline of the particle was analysed to distinguish which end of the dynein molecule was bound to the microtubule. The projected mass distribution was consistent with a model where the three dynein heads were oriented toward the microtubule and clearly not consistent with the opposite orientation. These data indicate that the three globular heads form the ATP-sensitive site in this heterologous dynein-microtubule system and suggest that the rootlike base of the dynein molecule forms the structural attachment site to the A-subfiber of the outer doublet in cilia and flagella. The structure and function of the dynein are dicussed in terms of these new results.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1083/jcb.96.3.669

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The molecular weights of these dynein complexes have been estimated by scanning transmission electron microscopy to be between 1 million and 2 million daltons.

    “The molecular weights of these dynein complexes have been estimated by scanning transmission electron microscopy to be between 1 million and 2 million daltons (Witman et al., 1983; Johnson and Wall, 1983).”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Johnson, K., & Wall, J.
Venue
The Journal of Cell Biology
Published
1983-03-01
Volume
96
Issue
3
Pages
669-678
ISSN
  • 0021-9525 (ISSN-L)
  • 1540-8140
OpenAlex
W2030791887
Cited by
191
References
1
Citations by year
2026: 1 · 2025: 3 · 2023: 2 · 2022: 2 · 2021: 1 · 2020: 1 · 2019: 2 · 2017: 6 · 2016: 1 · 2015: 2 · 2013: 1 · 2012: 1
FWCI
10.48
Type
journal article
Language
en
Open access
Licence
cc-by-nc-sa
Locations
  • The Journal of Cell Biology (publishedVersion)
  • PubMed Central (publishedVersion, cc-by-nc-sa)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Genetic and Kidney Cyst Diseases
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Structural Biology › Advanced Electron Microscopy Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Microtubule and mitosis dynamics
Keywords
dynein ATPase, molecular weight, dynein motor, ciliary dynein, ATPase site, scanning transmission electron microscopy, mass analysis
MeSH terms
Adenosine Triphosphatases, Animals, Binding Sites, Chemistry, Dyneins, Microscopy, Electron, Scanning, Microtubules, Molecular Weight, Protein Conformation, Structure-Activity Relationship, Tetrahymena, Chemical Phenomena

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review