The DOI matches its Crossref record.
Nonequilibrium gating and voltage dependence of the ClC-0 Cl- channel.
Open accessAbstract
The gating of ClC-0, the voltage-dependent Cl- channel from Torpedo electric organ, is strongly influenced by Cl- ions in the external solution. Raising external Cl- over the range 1-600 mM favors the fast-gating open state and disfavors the slow-gating inactivated state. Analysis of purified single ClC-0 channels reconstituted into planar lipid bilayers was used to identify the role of Cl- ions in the channel's fast voltage-dependent gating process. External, but not internal, Cl- had a major effect on the channel's opening rate constant. The closing rate was more sensitive to internal Cl- than to external Cl-. Both opening and closing rates varied with voltage. A model was derived that postulates (a) that in the channel's closed state, Cl- is accessible to a site located at the outer end of the conduction pore, where it binds in a voltage-independent fashion, (b) that this closed conformation can open, whether liganded by Cl- or not, in a weakly voltage-dependent fashion, (c) that the Cl(-)-liganded closed channel undergoes a conformational change to a different closed state, such that concomitant with this change, Cl- ion moves inward, conferring voltage-dependence to this step, and (d) that this new Cl(-)-liganded closed state opens with a very high rate. According to this picture, Cl- movement within the pre-open channel is the major source of voltage dependence, and charge movement intrinsic to the channel protein contributes very little to voltage-dependent gating of ClC-0. Moreover, since the Cl- activation site is probably located in the ion conduction pathway, the fast gating of ClC-0 is necessarily coupled to ion conduction, a nonequilibrium process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
X-ray structure of a ClC chloride channel at 3.0 Å reveals the molecular basis of anion selectivity
Dutzler, R., Campbell, E. B., Cadene, M., Chait, B. T., & MacKinnon, R. (2002) · Nature · doi:10.1038/415287a · Cited by 1,446
Molecular Structure and Physiological Function of Chloride Channels
Jentsch, T. J., Stein, V., Weinreich, F., & Zdebik, A. A. (2002) · Physiological Reviews · doi:10.1152/physrev.00029.2001 · Cited by 1,256
Gating the Selectivity Filter in ClC Chloride Channels
Dutzler, R., Campbell, E. B., & MacKinnon, R. (2003) · Science · doi:10.1126/science.1082708 · Cited by 727
Uncoupling and Turnover in a Cl−/H+ Exchange Transporter
Walden, M., Accardi, A., Wu, F., Xu, C., Williams, C., & Miller, C. (2007) · The Journal of General Physiology · doi:10.1085/jgp.200709756 · Cited by 142
Self-citationStructure and gating of CLC channels and exchangers
Accardi, A. (2015) · The Journal of Physiology · doi:10.1113/jp270575 · Cited by 78
Metadata
- Authors
- Chen, T. Y., & Miller, C.
- Venue
- The Journal of general physiology
- Publisher
- Rockefeller University Press
- Published
- 1996-10-01
- Volume
- 108
- Issue
- 4
- Pages
- 237-250
- ISSN
- 0022-1295 (ISSN-L)
- 1540-7748
- OpenAlex
- W2135106801
- Cited by
- 231
- References
- 0
- FWCI
- 4.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nonequilibrium gating and voltage dependence of the ClC-0 Cl- channel. https://app.cochat.ai/papers/10.1085/jgp.108.4.237
- The paper
- Chen, T. Y., & Miller, C. (1996). Nonequilibrium gating and voltage dependence of the ClC-0 Cl- channel. The Journal of general physiology. https://doi.org/10.1085/jgp.108.4.237
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.