CoChat

Biophysical Properties of Connexin-45 Gap Junction Hemichannels Studied in Vertebrate Cells

Open access
Valiunas, Virginijus · 2002 · The Journal of General Physiology
Cited by 148

The DOI matches its Crossref record.

Abstract

Human HeLa cells transfected with mouse Cx45 and rat RIN cells transfected with chicken Cx45 were used to study the electrical and permeability properties of Cx45 gap junction hemichannels. With no extracellular Ca2+, whole-cell recording revealed currents arising from hemichannels in both transfected cell lines. Multichannel currents showed a time-dependent activation or deactivation sensitive to voltage, Vm. These currents did not occur in nontransfected cells. The hemichannel currents were inhibited by raising extracellular Ca2+ or by acidification with CO2. The unitary conductance exhibited Vm dependence (i.e., γhc,main increased/decreased with hyperpolarization/depolarization). Extrapolation to Vm = 0 mV led to a γhc,main of 57 pS, roughly twice the conductance of an intact Cx45 gap junction channel. The open channel probability, Po, was Vm-dependent, declining at negative Vm (Po < 0.11, Vm < −50 mV), and increasing at positive Vm (Po ∼0.76, Vm > 50 mV). Moreover, Cx45 nonjunctional hemichannels appeared to mediate lucifer yellow (LY) and propidium iodide (PI) dye uptake from the external solution when extracellular Ca2+ level was reduced. Dye uptake was directly proportional to the number of functioning hemichannels. No significant dye uptake was detected in nontransfected cells. Cx45 transfected HeLa and RIN cells also allowed dye to leak out when preloaded with LY and then incubated in Ca2+-free external solution, whereas little or no dye leakage was observed when these cells were incubated with 2 mM external Ca2+. Intact Cx45 gap junction channels allowed passage of either LY or PI dye, but their respective flux rates were different. Comparison of LY diffusion through Cx45 hemichannels and intact gap junction channels revealed that the former is more permeable, suggesting that gap junction channel pores exhibit more allosterical restriction to the dye molecules than the unopposed hemichannel. The data demonstrate the opening of Cx45 nonjunctional hemichannels in vertebrate cells when the external Ca2+ concentration is reduced.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1085/jgp.119.2.147

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 148

Metadata

Authors
Valiunas, V.
Venue
The Journal of General Physiology
Published
2002-01-17
Volume
119
Issue
2
Pages
147-164
ISSN
  • 0022-1295 (ISSN-L)
  • 1540-7748
OpenAlex
W2011908808
Cited by
148
References
0
FWCI
3.46
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Biophysical Properties of Connexin-45 Gap Junction Hemichannels Studied in Vertebrate Cells. https://app.cochat.ai/papers/10.1085/jgp.119.2.147
The paper
Valiunas, V. (2002). Biophysical Properties of Connexin-45 Gap Junction Hemichannels Studied in Vertebrate Cells. The Journal of General Physiology. https://doi.org/10.1085/jgp.119.2.147

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.