Specificity of Charge-carrying Residues in the Voltage Sensor of Potassium Channels
Open accessThe DOI matches its Crossref record.
Abstract
Positively charged voltage sensors of sodium and potassium channels are driven outward through the membrane's electric field upon depolarization. This movement is coupled to channel opening. A recent model based on studies of the KvAP channel proposes that the positively charged voltage sensor, christened the “voltage-sensor paddle”, is a peripheral domain that shuttles its charged cargo through membrane lipid like a hydrophobic cation. We tested this idea by attaching charged adducts to cysteines introduced into the putative voltage-sensor paddle of Shaker potassium channels and measuring fractional changes in the total gating charge from gating currents. The only residues capable of translocating attached charges through the membrane-electric field are those that serve this function in the native channel. This remarkable specificity indicates that charge movement involves highly specialized interactions between the voltage sensor and other regions of the protein, a mechanism inconsistent with the paddle model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sodium Channel Inactivation: Molecular Determinants and Modulation
Ulbricht, W. (2005) · Physiological Reviews · doi:10.1152/physrev.00024.2004 · Cited by 306
How Does Voltage Open an Ion Channel?
Tombola, F., Pathak, M. M., & Isacoff, E. Y. (2006) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev.cellbio.21.020404.145837 · Cited by 303
Sensing voltage across lipid membranes
Swartz, K. J. (2008) · Nature · doi:10.1038/nature07620 · Cited by 293
Voltage-Sensing Arginines in a Potassium Channel Permeate and Occlude Cation-Selective Pores
Tombola, F., Pathak, M. M., & Isacoff, E. Y. (2005) · Neuron · doi:10.1016/j.neuron.2004.12.047 · Cited by 255
K+Channels: Function‐Structural Overview
González, C., Baez‐Nieto, D., Valencia, I., Oyarzún, I., Rojas, P., Naranjo, D., & Latorre, R. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c110047 · Cited by 223
“Consistent with this latter expectation, S4 tolerates additional charged side chains, negative and positive, added in a number of positions in S4 (4, 160).”
Metadata
- Authors
- Ahern, C. A., & Horn, R.
- Venue
- The Journal of General Physiology
- Publisher
- Rockefeller University Press
- Published
- 2004-02-09
- Volume
- 123
- Issue
- 3
- Pages
- 205-216
- ISSN
- 0022-1295 (ISSN-L)
- 1540-7748
- OpenAlex
- W2094817280
- Cited by
- 87
- References
- 0
- FWCI
- 4.37
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Specificity of Charge-carrying Residues in the Voltage Sensor of Potassium Channels. https://app.cochat.ai/papers/10.1085/jgp.200308993
- The paper
- Ahern, C. A., & Horn, R. (2004). Specificity of Charge-carrying Residues in the Voltage Sensor of Potassium Channels. The Journal of General Physiology. https://doi.org/10.1085/jgp.200308993
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.