Synaptotagmin isoforms confer distinct activation kinetics and dynamics to chromaffin cell granules
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Adrenomedullary chromaffin cells respond to sympathetic nervous system activation by secreting a cocktail of potent neuropeptides and hormones into the circulation. The distinct phases of the chromaffin cell secretory response have been attributed to the progressive fusion of distinct populations of dense core granules with different activation kinetics. However, it has been difficult to define what distinguishes these populations at the molecular level. Functional segregation of granule pools may depend on selective sorting of synaptotagmin-1 (Syt-1) and synaptotagmin-7 (Syt-7), which our previous work showed are rarely cosorted to the same granule. Here we assess the consequences of selective sorting of Syt isoforms in chromaffin cells, particularly with respect to granule dynamics and activation kinetics. Upon depolarization of cells expressing fluorescent Syt isoforms using elevated K+, we find that Syt-7 granules fuse with faster kinetics than Syt-1 granules, irrespective of stimulation strength. Pharmacological blockade of Ca2+ channels reveals differential dependence of Syt-1 versus Syt-7 granule exocytosis on Ca2+ channel subtypes. Syt-7 granules also show a greater tendency to fuse in clusters than Syt-1 granules, and granules harboring Syt-1 travel a greater distance before fusion than those with Syt-7, suggesting that there is spatial and fusion-site heterogeneity among the two granule populations. However, the greatest functional difference between granule populations is their responsiveness to Ca2+. Upon introduction of Ca2+ into permeabilized cells, Syt-7 granules fuse with fast kinetics and high efficacy, even at low Ca2+ levels (e.g., when cells are weakly stimulated). Conversely, Syt-1 granules require a comparatively larger increase in intracellular Ca2+ for activation. At Ca2+ concentrations above 30 µM, activation kinetics are faster for Syt-1 granules than for Syt-7 granules. Our study provides evidence for functional specialization of chromaffin cell granules via selective expression of Syt isoforms with different Ca2+ sensitivities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Synaptotagmin: a Calcium Sensor on the Synaptic Vesicle Surface
Brose, N., Petrenko, A. G., Südhof, T. C., & Jahn, R. (1992) · Science · doi:10.1126/science.1589771 · Cited by 979
Estimating Intracellular Calcium Concentrations and Buffering without Wavelength Ratioing
Maravall, M., Mainen, Z. F., Sabatini, B. L., & Svoboda, K. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76809-3 · Cited by 416
Munc18-1 Promotes Large Dense-Core Vesicle Docking
Voets, T., Toonen, R. F., Brian, E. C., de Wit, H., Moser, T., Rettig, J., Südhof, T. C., Neher, E., & Verhage, M. (2001) · Neuron · doi:10.1016/s0896-6273(01)00391-9 · Cited by 396
Calcium signaling and exocytosis in adrenal chromaffin cells
García, A. G., García-De-Diego, A. M., Gandía, L., Borges, R., & García-Sancho, J. (2006) · Physiological Reviews · doi:10.1152/physrev.00039.2005 · Cited by 349
The voltage sensitive Lc-type Ca 2+ channel is functionally coupled to the exocytotic machinery
Wiser, O., Trus, M., Hernández, A., Renström, E., Barg, S., Rorsman, P., & Atlas, D. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.1.248 · Cited by 284
Bal, M., Leitz, J., Reese, A. L., Ramirez, D. M. O., Durakoglugil, M., Herz, J., Monteggia, L. M., & Kavalali, E. T. (2013) · Neuron · doi:10.1016/j.neuron.2013.08.024 · Cited by 131
Zhu, D., Koo, E., Kwan, E., Kang, Y., Park, S., Xie, H., Sugita, S., & Gaisano, H. Y. (2013) · Diabetologia · doi:10.1007/s00125-012-2757-0 · Cited by 81
Cited by
SNARE-Mediated Exocytosis in Neuronal Development
Urbina, F. L., & Gupton, S. L. (2020) · Frontiers in Molecular Neuroscience · doi:10.3389/fnmol.2020.00133 · Cited by 48
“Synaptotagmin-1 regulated fusion exhibited slower fusion kinetics and was less spatiallyclustered than synaptotagmin-7 fusion, suggesting diversity in vesicle population fusion (Rao et al., 2017).”
BackgroundHighly adaptable deep-learning platform for automated detection and analysis of vesicle exocytosis
Chouaib, A. A., Chang, H.-F., Khamis, O. M., Alawar, N., Echeverry, S., Demeersseman, L., Elizarova, S., Daniel, J. A., Tian, Q., Lipp, P., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-61579-3 · Cited by 11
“…used approach to follow exocytic events occurring during neuronal synaptic transmission in live imaging relies on the expression of vesicularproteins tagged with pH sensitive fl uorophores such as the super ecliptic pHluorin (SEP) 6 – 8 or on other types of mar-kerssuchasthelipophilicFMdyes 9 – 11 .”
PACAP and acetylcholine cause distinct Ca2+ signals and secretory responses in chromaffin cells
Morales, A., Mohan, R., Chen, X., Coffman, B. L., Bendahmane, M., Watch, L., West, J. L., Bakshi, S., Traynor, J. R., Giovannucci, D. R., et al. (2023) · Journal of General Physiology · doi:10.1085/jgp.202213180 · Cited by 9
Self-citationHighly adaptable deep-learning platform for automated detection and analysis of vesicle exocytosis
Chouaib, A. A., Chang, H.-F., Khamis, O. M., Echeverry, S., Demeersseman, L., Elizarova, S., Daniel, J. A., Valitutti, S., Barg, S., Pape, C., et al. (2024) · doi:10.1101/2024.08.02.606323 · Cited by 1
Metadata
- Authors
- Rao, T. C., Santana Rodriguez, Z., Bradberry, M. M., Ranski, A. H., Dahl, P. J., Schmidtke, M. W., Jenkins, P. M., Axelrod, D., Chapman, E. R., Giovannucci, D. R., & Anantharam, A.
- Venue
- Journal of General Physiology
- Publisher
- Rockefeller University Press
- Published
- 2017-07-07
- Volume
- 149
- Issue
- 8
- Pages
- 763-780
- ISSN
- 0022-1295 (ISSN-L)
- 1540-7748
- OpenAlex
- W2731280167
- Cited by
- 33
- References
- 7
- FWCI
- 2.66
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.