The DOI matches its Crossref record.
Temperature-dependent changes of chloride transport kinetics in human red cells.
Open accessAbstract
Chloride self-exchange in human red cells was studied between 0 degrees C and 38 degrees C. At higher temperatures the flow-tube method was used. Although the general features of chloride transport at 0 degrees C and 38 degrees C are similar, the following differences were found: (a) the maximum pH of chloride self-exchange flux was lowered 0.6 pH unit from 7.8 to 7.2 when temperature was increased from 0 degrees C to 38 degrees C; (b)the apparent half-saturation constant increased from 28 mM at 0 degrees C to 65 mM at 38 degrees C; (c) chloride transport at body temperature is slower than predicted by other investigators by extrapolation from low-temperature results. Chloride transport increased only 200 times when temperature was raised from 0 degrees C to 38 degrees C, because the apparent activation energy decreased from 30 kcal mol(-1) to 20 kcal mol(-1) above a temperature of 15 degrees C; (d) a study of temperature dependence of the slower bromide self-exchange showed that a similar change of activation energy occurred around 25 degrees C. Both in the case of Cl(-) (15 degrees C) and in the case of Br(-) (25 degrees C), critical temperature was reached when the anion self-exchange had a turnover number of about 4x10(9) ions cell (-1)s(-1); (e) inhibition of chloride transport by DIDS (4,4'- diisothiocyano-stilbene-2,2'-disulfonate)revealed that the deflection persisted at 15 degrees C at partial inhibition (66 percent) presumably because DIDS inactivated 66 percent of the transport sites. It is suggested that a less temperature- dependent step of anion exchange becomes rate limiting at the temperature where a critical turnover number is reached.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mechanisms by which mitochondria transport calcium
Gunter, T. E., & Pfeiffer, D. R. (1990) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1990.258.5.c755 · Cited by 1,640
Ioav Cabantchik, Z., Knauf, P. A., & Rothstein, A. (1978) · Biochimica et Biophysica Acta (BBA) - Reviews on Biomembranes · doi:10.1016/0304-4157(78)90016-3 · Cited by 721
Yanagibashi, K., & Hall, P. F. (1986) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)83930-3 · Cited by 171
Ion permeation through a Cl − -selective channel designed from a CLC Cl − /H + exchanger
Jayaram, H., Accardi, A., Wu, F., Williams, C., & Miller, C. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0804503105 · Cited by 101
Metadata
- Authors
- Brahm, J.
- Venue
- The Journal of general physiology
- Publisher
- Rockefeller University Press
- Published
- 1977-09-01
- Volume
- 70
- Issue
- 3
- Pages
- 283-306
- ISSN
- 0022-1295 (ISSN-L)
- 1540-7748
- OpenAlex
- W2101241746
- Cited by
- 257
- References
- 0
- FWCI
- 7.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Temperature-dependent changes of chloride transport kinetics in human red cells. https://app.cochat.ai/papers/10.1085/jgp.70.3.283
- The paper
- Brahm, J. (1977). Temperature-dependent changes of chloride transport kinetics in human red cells. The Journal of general physiology. https://doi.org/10.1085/jgp.70.3.283
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.