Spatiotemporal frequency responses of cat retinal ganglion cells.
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Spatiotemporal frequency responses were measured at different levels of light adaptation for cat X and Y retinal ganglion cells. Stationary sinusoidal luminance gratings whose contrast was modulated sinusoidally in time or drifting gratings were used as stimuli. Under photopic illumination, when the spatial frequency was held constant at or above its optimum value, an X cell's responsivity was essentially constant as the temporal frequency was changed from 1.5 to 30 Hz. At lower temporal frequencies, responsivity rolled off gradually, and at higher ones it rolled off rapidly. In contrast, when the spatial frequency was held constant at a low value, an X cell's responsivity increased continuously with temporal frequency from a very low value at 0.1 Hz to substantial values at temporal frequencies higher than 30 Hz, from which responsivity rolled off again. Thus, 0 cycles X deg-1 became the optimal spatial frequency above 30 Hz. For Y cells under photopic illumination, the spatiotemporal interaction was even more complex. When the spatial frequency was held constant at or above its optimal value, the temporal frequency range over which responsivity was constant was shorter than that of X cells. At lower spatial frequencies, this range was not appreciably different. As for X cells, 0 cycles X deg-1 was the optimal spatial frequency above 30 Hz. Temporal resolution (defined as the high temporal frequency at which responsivity had fallen to 10 impulses X s-1) for a uniform field was approximately 95 Hz for X cells and approximately 120 Hz for Y cells under photopic illumination. Temporal resolution was lower at lower adaptation levels. The results were interpreted in terms of a Gaussian center-surround model. For X cells, the surround and center strengths were nearly equal at low and moderate temporal frequencies, but the surround strength exceeded the center strength above 30 Hz. Thus, the response to a spatially uniform stimulus at high temporal frequencies was dominated by the surround. In addition, at temporal frequencies above 30 Hz, the center radius increased.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The contrast sensitivity of retinal ganglion cells of the cat
Enroth-Cugell, C., & Robson, J. G. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp008107 · Cited by 2,625 · cited 3×
“In this article, we deal only with X and Y retinal ganglion cells (Enroth-Cugell and Robson, 1966), which presumably correspond to the brisk-sustained and brisk-transient cells, respectively, of Cleland and Levick (1974) .”
Self-citationSpatial and Temporal Contrast-Sensitivity Functions of the Visual System
Robson, J. G. (1966) · Journal of the Optical Society of America · doi:10.1364/josa.56.001141 · Cited by 839
Cited by
Luminance and chromatic modulation sensitivity of macaque ganglion cells and human observers
Lee, B. B., Pokorny, J., Martin, P. R., Valbergt, A., & Smith, V. C. (1990) · Journal of the Optical Society of America A · doi:10.1364/josaa.7.002223 · Cited by 504
Chapter 7 New views of primate retinal function
Kaplan, E., Lee, B. B., & Shapley, R. M. (1990) · Progress in Retinal Research · doi:10.1016/0278-4327(90)90009-7 · Cited by 282
Priebe, N. J., Lisberger, S. G., & Movshon, J. A. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.3936-05.2006 · Cited by 273
“9B) (Enroth-Cugell et al., 1983; Hicks et al., 1983; Derrington and Lennie, 1984; Frishman et al., 1987).”
Retinal stimulation strategies to restore vision: fundamentals and systems
Yue, L., Weiland, J. D., Roska, B., & Humayun, M. S. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.05.002 · Cited by 272
“Earlier electrophysiological studies have predicted primate ganglion cell responses by a linear-nonlinear (LN) cascade model with a difference-of-Gaussians or wavelet-shaped characteristic spatial profile (Frishman et al., 1987; Meister and Berry, 1999; Rodieck et al., 1962; Van Rullen and Thorpe, 2001).”
Lateral interactions in the outer retina
Thoreson, W. B., & Mangel, S. C. (2012) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2012.04.003 · Cited by 262
Metadata
- Authors
- Frishman, L. J., Freeman, A. W., Troy, J. B., Schweitzer-Tong, D. E., & Enroth-Cugell, C.
- Venue
- The Journal of general physiology
- Publisher
- Rockefeller University Press
- Published
- 1987-04-01
- Volume
- 89
- Issue
- 4
- Pages
- 599-628
- ISSN
- 0022-1295 (ISSN-L)
- 1540-7748
- OpenAlex
- W2155170674
- Cited by
- 154
- References
- 2
- FWCI
- 3.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spatiotemporal frequency responses of cat retinal ganglion cells. https://app.cochat.ai/papers/10.1085/jgp.89.4.599
- The paper
- Frishman, L. J., Freeman, A. W., Troy, J. B., Schweitzer-Tong, D. E., & Enroth-Cugell, C. (1987). Spatiotemporal frequency responses of cat retinal ganglion cells. The Journal of general physiology. https://doi.org/10.1085/jgp.89.4.599
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.