The DOI matches its Crossref record.
THE ELECTRIC CAPACITY OF SUSPENSIONS WITH SPECIAL REFERENCE TO BLOOD
Open accessAbstract
1. The specific capacity of a suspension is that capacity which) combined in parallel with a certain resistance, electrically balances 1 cm. cube of the suspension. 2. The following formula holds for the specific capacity of a suspension of spheroids, each of which is composed of a well conducting interior surrounded by a thin membrane of a comparatively high resistance: See PDF for Equation C, specific capacity of suspension; Co, static capacity of one sq. cm. of membrane; r, r1 specific resistances respectively of suspension and of suspending liquid; 2 q major axis of spheroid, α constant tabulated in Table I. 3. The following formula holds practically for any suspension whatever the form of the suspended particle. See PDF for Equation C = C100 being the specific capacity of a suspension with a concentration of 100 per cent. Formulæ (1a) and (1b) hold only for the case, when the frequency is so low, that the impedance of the static capacity of the membrane around a single particle is high as compared with the resistance of the interior of the particle. The formulae hold also for a suspension of homogeneous particles, when polarization takes place at the surface of each particle, provided the polarization resistance is low as compared with the impedance of the polarization capacity. 4. A description is given of a method for measuring the capacity of a suspension at frequencies between 800 and 4½ million cycles. By means of a specially designed bridge, a substitution method is employed, by which in the last analysis the suspension is compared with the suspending liquid which is so diluted as to have the same specific resistance as the suspension, consecutive measurements being made in the same electrolytic cell. 5. Formula (1b) is verified by measurements of the capacity of suspensions of varying volume concentrations of the red corpuscles of a dog. 6. By means of the above measurements, the value of Co is calculated by equation (1a). 7. It is found that Co is independent of the frequency up to 4½ million cycles and that it is also independent of the suspending liquid. These results furnish considerable evidence of the validity of the theory, that Co represents the static capacity of a corpuscle membrane. 8. On this assumption and using a probable value for the dielectric constant of the membrane, the thickness of the membrane is calculated to be 3.3·10–7 cm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dielectric properties of body tissues
Pethig, R. (1987) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/8/4a/002 · Cited by 516
Leukocyte analysis and differentiation using high speed microfluidic single cell impedance cytometry
Holmes, D., Pettigrew, D., Reccius, C. H., Gwyer, J. D., van Berkel, C., Holloway, J., Davies, D. E., & Morgan, H. (2009) · Lab on a Chip · doi:10.1039/b910053a · Cited by 408
Harris, C. M., Todd, R. W., Bungard, S. J., Lovitt, R. W., Morris, J. G., & Kell, D. B. (1987) · Enzyme and Microbial Technology · doi:10.1016/0141-0229(87)90075-5 · Cited by 268
Caduff, A., Dewarrat, F., Talary, M., Stalder, G., Heinemann, L., & Feldman, Y. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.01.031 · Cited by 155
Metadata
- Authors
- Fricke, H.
- Venue
- Journal of General Physiology
- Publisher
- Rockefeller University Press
- Published
- 1925-11-20
- Volume
- 9
- Issue
- 2
- Pages
- 137-152
- ISSN
- 0022-1295 (ISSN-L)
- 1540-7748
- OpenAlex
- W2058534478
- Cited by
- 270
- References
- 0
- FWCI
- 1.87
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: THE ELECTRIC CAPACITY OF SUSPENSIONS WITH SPECIAL REFERENCE TO BLOOD. https://app.cochat.ai/papers/10.1085/jgp.9.2.137
- The paper
- Fricke, H. (1925). THE ELECTRIC CAPACITY OF SUSPENSIONS WITH SPECIAL REFERENCE TO BLOOD. Journal of General Physiology. https://doi.org/10.1085/jgp.9.2.137
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.