The DOI matches its Crossref record.
Low pO2 selectively inhibits K channel activity in chemoreceptor cells of the mammalian carotid body.
Open accessAbstract
The hypothesis that changes in environmental O2 tension (pO2) could affect the ionic conductances of dissociated type I cells of the carotid body was tested. Cells were subjected to whole-cell patch clamp and ionic currents were recorded in a control solution with normal pO2 (pO2 = 150 mmHg) and 3-5 min after exposure to the same solution with a lower pO2. Na and Ca currents were unaffected by lowering pO2 to 10 mmHg, however, in all cells studied (n = 42) exposure to hypoxia produced a reversible reduction of the K current. In 14 cells exposed to a pO2 of 10 mmHg peak K current amplitude decreased to 35 +/- 8% of the control value. The effect of low pO2 was independent of the internal Ca2+ concentration and was observed in the absence of internal exogenous nucleotides. Inhibition of K channel activity by hypoxia is a graded phenomenon and in the range between 70 and 120 mmHg, which includes normal pO2 values in arterial blood, it is directly correlated with pO2 levels. Low pO2 appeared to slow down the activation time course of the K current but deactivation kinetics seemed to be unaltered. Type I cells subjected to current clamp generate large Na- and Ca-dependent action potentials repetitively. Exposure to low pO2 produces a 4-10 mV increase in the action potential amplitude and a faster depolarization rate of pacemaker potentials, which leads to an increase in the firing frequency. Repolarization rate of individual action potentials is, however, unaffected, or slightly increased. The selective inhibition of K channel activity by low pO2 is a phenomenon without precedents in the literature that explains the chemoreceptive properties of type I cells. The nature of the interaction of molecular O2 with the K channel protein is unknown, however, it is argued that a hemoglobin-like O2 sensor, perhaps coupled to a G protein, could be involved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Peripheral Chemoreceptors: Function and Plasticity of the Carotid Body
Kumar, P., & Prabhakar, N. R. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100069 · Cited by 530
Oxygen sensing in airway chemoreceptors
Youngson, C., Nurse, C., Yeger, H., & Cutz, E. (1993) · Nature · doi:10.1038/365153a0 · Cited by 458
Regulation of oxygen sensing by ion channels
López-Barneo, J., del Toro, R., Levitsky, K. L., Chiara, M. D., & Ortega-Sáenz, P. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00929.2003 · Cited by 106
Self-citationK+ channels in O2 sensing and postnatal development of carotid body glomus cell response to hypoxia
Kim, D. (2013) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2012.07.005 · Cited by 24
Metadata
- Authors
- López-López, J., González, C., Ureña, J., & López-Barneo, J.
- Venue
- The Journal of general physiology
- Publisher
- Rockefeller University Press
- Published
- 1989-05-01
- Volume
- 93
- Issue
- 5
- Pages
- 1001-1015
- ISSN
- 0022-1295 (ISSN-L)
- 1540-7748
- OpenAlex
- W2014292100
- Cited by
- 203
- References
- 0
- FWCI
- 9.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Low pO2 selectively inhibits K channel activity in chemoreceptor cells of the mammalian carotid body. https://app.cochat.ai/papers/10.1085/jgp.93.5.1001
- The paper
- López-López, J., González, C., Ureña, J., & López-Barneo, J. (1989). Low pO2 selectively inhibits K channel activity in chemoreceptor cells of the mammalian carotid body. The Journal of general physiology. https://doi.org/10.1085/jgp.93.5.1001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.