The DOI matches its Crossref record; 235 of the 235 references it cites were found in a registry or an index.
Guidelines for the Prevention of Intravascular Catheter–Related Infections
Open accessAbstract
These guidelines have been developed for practitioners who insert catheters and for persons responsible for surveillance and control of infections in hospital, outpatient, and home health-care settings. This report was prepared by a working group comprising members from professional organizations representing the disciplines of critical care medicine, infectious diseases, health-care infection control, surgery, anesthesiology, interventional radiology, pulmonary medicine, pediatric medicine, and nursing. The working group was led by the Society of Critical Care Medicine (SCCM), in collaboration with the Infectious Disease Society of America (IDSA), Society for Healthcare Epidemiology of America (SHEA), Surgical Infection Society (SIS), American College of Chest Physicians (ACCP), American Thoracic Society (ATS), American Society of Critical Care Anesthesiologists (ASCCA), Association for Professionals in Infection Control and Epidemiology (APIC), Infusion Nurses Society (INS), Oncology Nursing Society (ONS), Society of Cardiovascular and Interventional Radiology (SCVIR), American Academy of Pediatrics (AAP), and the Healthcare Infection Control Practices Advisory Committee (HICPAC) of the Centers for Disease Control and Prevention (CDC) and is intended to replace the Guideline for Prevention of Intravascular Device–Related Infections published in 1996. These guidelines are intended to provide evidence-based recommendations for preventing catheter-related infections. Major areas of emphasis include 1) educating and training health-care providers who insert and maintain catheters; 2) using maximal sterile barrier precautions during central venous catheter insertion; 3) using a 2% chlorhexidine preparation for skin antisepsis; 4) avoiding routine replacement of central venous catheters as a strategy to prevent infection; and 5) using antiseptic/antibiotic impregnated short-term central venous catheters if the rate of infection is high despite adherence to other strategies (i.e., education and training, maximal sterile barrier precautions, and 2% chlorhexidine for skin antisepsis). These guidelines also identify performance indicators that can be used locally by health-care institutions or organizations to monitor their success in implementing these evidence-based recommendations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–235 of 235
Loisel, D. B., Smith, M., MacDonald, M. G., et al. (1997) · PubMed · Cited by 54
Nosocomial infections associated with long-term radial artery cannulation
Leroy, O., Billiau, V., Beuscart, C., Santré, C., Chidiac, C., Ramage, C., & Mouton, Y. (1989) · Intensive Care Medicine · doi:10.1007/bf00271059 · Cited by 53
Locci, R., Peters, G., & Pulverer, G. (1981) · PubMed · Cited by 53
Ankola, P. A., & Atakent, Y. (2008) · American Journal of Perinatology · doi:10.1055/s-2007-994726 · Cited by 52
Umbilical Venous Catheterizations: Audit by the Study Group for Complications of Perinatal Care
Seguin, J., FLETCHER, M. A., Landers, S., et al. (1994) · American Journal of Perinatology · doi:10.1055/s-2007-994540 · Cited by 52
Hanna, H. A., & RAAD, I. I. (2001) · Infection Control and Hospital Epidemiology · doi:10.1086/501885 · Cited by 52
Self-citationLuebke, M., Arduino, M. J., Duda, D. L., et al. (1998) · American Journal of Infection Control · doi:10.1016/s0196-6553(98)70042-2 · Cited by 51
Extended use of disposable pressure transducers. A bacteriologic evaluation
Luskin, R. L. (1986) · JAMA · doi:10.1001/jama.255.7.916 · Cited by 51
Khuri-Bulos, N. A., Shennak, M. M., Agabi, S. S., Saleh, S., Rawashdeh, S. A., Ghanem, S. A., Adham, M. A., Faori, I., & Khader, I. A. (1999) · American Journal of Infection Control · doi:10.1016/s0196-6553(99)70035-0 · Cited by 50
Preventing Central Venous Catheter-Related Infection in a Surgical Intensive-Care Unit
Bijma, R., Girbes, A. R. J., Kleijer, D. J., et al. (1999) · Infection Control and Hospital Epidemiology · doi:10.1086/501682 · Cited by 50
A prospective clinical study toinvestigate the microbial contamination ofa needleless connector
Seymou, V. M., Dhallu, T. S., Mos, H. A., et al. (2000) · Journal of Hospital Infection · doi:10.1053/jhin.2000.0726 · Cited by 49
The potential for catheter microbial contamination from a needleless connector
Brown, J. D., Moss, H., & Elliott, T. S. J. (1997) · Journal of Hospital Infection · doi:10.1016/s0195-6701(97)90193-6 · Cited by 47
Prevention of Umbilical Artery Catheter Clots with Heparinized Infusates
David, R. J., Merten, D. F., Anderson, J. C., et al. (2019) · Developmental Pharmacology and Therapeutics · doi:10.1159/000481037 · Cited by 43
Prevention of Catheter‐Related Sepsis During Parenteral Nutrition: Effect of a NeW Connection Device
Inoue, Y., Nezu, R., Matsuda, H., et al. (1992) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607192016006581 · Cited by 43
Cohen, Y., Fosse, J. P., Karoubi, P., et al. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.1.97-03067 · Cited by 42
Incidence of Deep Venous Thrombosis Associated with Femoral Venous Catheterization
Mian, N. Z., Bayly, R., Schreck, D. M., et al. (1997) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.1997.tb03693.x · Cited by 42
Microbiologic evaluation of needleless and needle-access devices
Arduino, M. J., Bland, L. A., Danzig, L. E., et al. (1997) · American Journal of Infection Control · doi:10.1016/s0196-6553(97)90081-x · Cited by 42
Maki, D. G., & McCormack, K. N. (1987) · The American Journal of Medicine · doi:10.1016/0002-9343(87)90639-5 · Cited by 41
Self-citationInfectious complications during peripheral intravenous therapy with Teflon(r) catheters
Garland, J. S., Nelson, D. B., Cheah, T., et al. (1987) · The Pediatric Infectious Disease Journal · doi:10.1097/00006454-198710000-00012 · Cited by 40
Surveillance of intravenous catheter-related infections among home care patients
White, M. C., & Ragland, K. E. (1994) · American Journal of Infection Control · doi:10.1016/0196-6553(94)99002-6 · Cited by 40
Madeo, M., Martin, C. R., Turner, C., et al. (1998) · Intensive and Critical Care Nursing · doi:10.1016/s0964-3397(98)80512-0 · Cited by 40
Iatrogenic Contamination of Multidose Vials in Simulated Use
Plott, R. T. (1990) · Archives of Dermatology · doi:10.1001/archderm.1990.01670350055006 · Cited by 39
Harwood, I. R., Greene, L. M., Kozakowski‐Koch, J. A., et al. (1992) · Pediatric Pulmonology · doi:10.1002/ppul.1950120407 · Cited by 36
Correction: Catheter-Related Bloodstream Infections
(2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-133-5-200009050-00026 · Cited by 35
Swimming and Central Venous Catheter-Related Infections in the Child With Cancer
Robbins, J., Cromwell, P., & Korones, D. N. (1999) · Journal of Pediatric Oncology Nursing · doi:10.1177/104345429901600107 · Cited by 33
Epidemic Bloodstream Infections from Hemodynamic Pressure Monitoring: Signs of the Times
Mermel, L. A., & Maki, D. G. (1989) · Infection Control and Hospital Epidemiology · doi:10.2307/30146456 · Cited by 32
Self-citationMILLER, K. L., Coen, P. E., White, W. J., et al. (1989) · Health Physics · doi:10.1097/00004032-198906000-00009 · Cited by 31
Cohran, J., Larson, E., Roach, H., Blane, C., & Pierce, P. F. (1996) · Heart & Lung · doi:10.1016/s0147-9563(96)80120-8 · Cited by 29
Infections and Infection Risks in Home Care Settings
White, M. C. (1992) · Infection Control and Hospital Epidemiology · doi:10.1086/646593 · Cited by 28
Surveillance of infection in home care
Lorenzen, A. N., & Itkin, D. J. (1992) · American Journal of Infection Control · doi:10.1016/s0196-6553(05)80238-x · Cited by 27
The i.v. therapy team: impact on patient care and costs of hospitalization.
Tomford, J. W., & Hershey, C. O. (1985) · PubMed · Cited by 25
Management of catheter-related bacteremia and fungemia in patients on total parenteral nutrition
Widmer, A. F. (1997) · Nutrition · doi:10.1016/s0899-9007(97)00218-9 · Cited by 22
Locci, R., Peters, G., & Pulverer, G. (1981) · PubMed · Cited by 21
Performance of a new softening expanding midline catheter in home intravenous therapy patients.
Pj, F. (1991) · PubMed · Cited by 18
Infection potential of nondisposable pressure transducers prepared prior to use
TENOLD, R., PRIANO, L. L., Kim, K., et al. (1987) · Critical Care Medicine · doi:10.1097/00003246-198706000-00007 · Cited by 14
Cited by
Surviving Sepsis Campaign: International Guidelines for Management of Severe Sepsis and Septic Shock
Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., Jaeschke, R., et al. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31827e83af · Cited by 9,694
The Surviving Sepsis Campaign Guidelines Committee including The Pediatric Subgroup*, Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., et al. (2013) · Intensive Care Medicine · doi:10.1007/s00134-012-2769-8 · Cited by 7,290
Dellinger, R. P., Levy, M. M., Carlet, J. M., Bion, J., Parker, M. M., Jaeschke, R., Reinhart, K., Angus, D. C., Brun-Buisson, C., Beale, R., et al. (2008) · Intensive Care Medicine · doi:10.1007/s00134-007-0934-2 · Cited by 6,772
Epidemiology of Invasive Candidiasis: a Persistent Public Health Problem
Pfaller, M. A., & Diekema, D. J. (2007) · Clinical Microbiology Reviews · doi:10.1128/cmr.00029-06 · Cited by 4,174
Surviving Sepsis Campaign guidelines for management of severe sepsis and septic shock
Dellinger, R. P., Carlet, J. M., Masur, H., Gerlach, H., Calandra, T., Cohen, J., Gea-Banacloche, J., Keh, D., Marshall, J. C., Parker, M. M., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000117317.18092.e4 · Cited by 3,018
Self-citation
Metadata
- Authors
- O'Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., Raad, I. I., Randolph, A., & Weinstein, R. A.
- Venue
- Clinical Infectious Diseases
- Publisher
- Oxford University Press (OUP)
- Published
- 2002-12-01
- Volume
- 35
- Issue
- 11
- Pages
- 1281-1307
- ISSN
- 1058-4838 (ISSN-L)
- 1537-6591
- OpenAlex
- W2508954902
- Cited by
- 440
- References
- 235
- FWCI
- 36.28
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.