The DOI matches its Crossref record.
A Review of Single-Use and Reusable Gowns and Drapes in Health Care
Open accessAbstract
Gowns and drapes are used widely in healthcare facilities. Gowns have been used to minimize the risk of disease acquisition by healthcare providers, to reduce the risk of patient-to-patient transmission, and during invasive procedures to aid in maintaining a sterile field. Drapes have been used during invasive procedures to maintain the sterility of environmental surfaces, equipment, and patients. This article reviews the use of gowns and drapes in healthcare facilities, including the characteristics, costs, benefits, and barrier effectiveness of single-use and reusable products. Currently, gowns protect healthcare personnel performing invasive procedures from contact with bloodborne pathogens. Although gowns have been recommended to prevent patient-to-patient transmission in certain settings (eg, neonatal intensive care unit) and for certain patients (eg, those infected with vancomycin-resistant enterococci), scientific studies have produced mixed results of their efficacy. While appropriate use of drapes during invasive procedures is recommended widely as an aid in minimizing contamination of the operative field, the efficacy of this practice in reducing surgical-site infections has not been assessed by scientific studies. Based on an evaluation of the functional requirements, environmental impact, and economics of gowns and drapes, clear superiority of either reusable or single-use gowns and drapes cannot be demonstrated. The selection of particular gowns and drapes by individual healthcare facilities requires an assessment of the facility's requirements, available products, and costs and should be based on the desired characteristics of an ideal gown or drape as defined in this paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sustainable Personal Protective Clothing for Healthcare Applications: A Review
Karim, N., Afroj, S., Lloyd, K., Oaten, L. C., Andreeva, D. V., Carr, C., Farmery, A. D., Kim, I.-D., & Novoselov, K. S. (2020) · ACS Nano · doi:10.1021/acsnano.0c05537 · Cited by 438
A Comparison of Reusable and Disposable Perioperative Textiles: Sustainability State-of-the-Art 2012
Overcash, M. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31824d9cc3 · Cited by 240
People, planet and profits: the case for greening operating rooms
Kagoma, Y., Stall, N., Rubinstein, E., & Naudie, D. (2012) · Canadian Medical Association Journal · doi:10.1503/cmaj.112139 · Cited by 229
How Ophthalmologists Can Decarbonize Eye Care
Sherry, B., Lee, S., Ramos Cadena, M. D. L. A., Laynor, G., Patel, S. R., Simon, M. D., Romanowski, E. G., Hochman, S. E., Schuman, J. S., Prescott, C., et al. (2023) · Ophthalmology · doi:10.1016/j.ophtha.2023.02.028 · Cited by 47
Metadata
- Authors
- Rutala, W. A., & Weber, D. J.
- Venue
- Infection Control & Hospital Epidemiology
- Publisher
- Cambridge University Press (CUP)
- Published
- 2001-04
- Volume
- 22
- Issue
- 4
- Pages
- 248-257
- ISSN
- 0899-823X (ISSN-L)
- 1559-6834
- OpenAlex
- W2118743622
- Cited by
- 176
- References
- 0
- FWCI
- 1.43
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Review of Single-Use and Reusable Gowns and Drapes in Health Care. https://app.cochat.ai/papers/10.1086/501895
- The paper
- Rutala, W. A., & Weber, D. J. (2001). A Review of Single-Use and Reusable Gowns and Drapes in Health Care. Infection Control & Hospital Epidemiology. https://doi.org/10.1086/501895
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.