Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 199

The DOI matches its Crossref record.

The Use of Transient Elastometry for Assessing Liver Fibrosis in Patients with HIV and Hepatitis C Virus Coinfection

Vergara, S., Macias, J., Rivero, A., Gutierrez-Valencia, A., Gonzalez-Serrano, M., Merino, D., Rios, M. J., Garcia-Garcia, J. A., Camacho, A., Lopez-Cortes, L., Ruiz, J., de la Torre, J., Viciana, P., Pineda, J. A., Grupo para el Estudio de las Hepatitis Viricas de la SAEI · 2007 · Clinical Infectious Diseases

Abstract

BACKGROUND: Transient elastometry (TE) is accurate for detecting significant liver fibrosis and cirrhosis in hepatitis C virus (HCV)-monoinfected patients. However, this procedure has been insufficiently validated in patients with human immunodeficiency virus (HIV) and HCV coinfection. The purpose of this study was to validate reported cutoff values of TE that discriminate significant liver fibrosis and cirrhosis in HIV-HCV-coinfected subjects. METHODS: Liver stiffness measurements were obtained for 169 HIV-HCV-coinfected adult patients who had undergone a liver biopsy or who had received a nonhistologic diagnosis of cirrhosis within 12 months before or after a liver stiffness measurement. Patients had received no prior therapy for HCV infection. RESULTS: TE measurements ranged from 3.6 kPa to 75 kPa. The area under the receiver operating characteristic curve was 0.87 (95% confidence interval, 0.84-0.93) for significant liver fibrosis and 0.95 (95% confidence interval, 0.92-0.99) for cirrhosis. To diagnose significant liver fibrosis, a cutoff value of 7.2 kPa was associated with a positive predictive value of 88% and a negative predictive value of 75%. Thirty-four patients (20%) were misclassified when this cutoff value was used. Thirteen (24%) of 54 patients with liver stiffness values <7.2 kPa had significant liver fibrosis detected by liver biopsy. To diagnose cirrhosis, a cutoff value of 14.6 kPa was associated with a positive predictive value of 86% and a negative predictive value of 94%. Thus, 13 patients (10%) had disease that was misclassified using this cutoff value. CONCLUSIONS: We found that the diagnostic accuracy of TE was high for detecting cirrhosis and good for diagnosis of significant liver fibrosis. However, the performance of TE was low for discriminating mild fibrosis from significant liver fibrosis, which might limit the applicability of this technique in clinical practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1086/521857

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Vergara, S., Macias, J., Rivero, A., Gutierrez-Valencia, A., Gonzalez-Serrano, M., Merino, D., Rios, M. J., Garcia-Garcia, J. A., Camacho, A., Lopez-Cortes, L., Ruiz, J., de la Torre, J., Viciana, P., Pineda, J. A., & Grupo para el Estudio de las Hepatitis Viricas de la, S. A. E. I.
Venue
Clinical Infectious Diseases
Published
2007-10-15
Volume
45
Issue
8
Pages
969-974
ISSN
  • 1058-4838 (ISSN-L)
  • 1537-6591
OpenAlex
W2126662952
Cited by
199
References
0
FWCI
9.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.