Use of Light‐Emitting Diode Fluorescence Microscopy to Detect Acid‐Fast Bacilli in Sputum
The DOI matches its Crossref record.
Abstract
BACKGROUND: Fluorescence microscopy offers well-described benefits, compared with conventional light microscopy, for the evaluation of sputum smear samples for tuberculosis. However, its use in resource-limited settings has been limited by the high cost of the excitatory light source. We evaluated the diagnostic performance of fluorescence microscopy, using novel light-emitting diode (LED) technology as an alternative to the conventional mercury vapor lamp (MVP). METHODS: Routinely collected sputum specimens from persons suspected to have tuberculosis who attended community clinics were stained with auramine O and were evaluated using 2 different excitatory light sources (MVP and LED); these specimens were then Ziehl-Neelsen stained and reexamined using light microscopy. Two microscopists independently evaluated all smears. Bacterial culture provided the gold standard. RESULTS: Of the 221 sputum specimens evaluated, 36 (16.3%) were positive for Mycobacterium tuberculosis by culture. Sensitivity and specificity documented for the different modalities were 84.7% and 98.9%, respectively, for the LED assessment; 73.6% and 99.8%, respectively, for the MVP assessment; and 61.1% and 98.9%, respectively, for light microscopy. kappa values for interreader variation were 0.87 for the LED assessment, 0.79 for the MVP assessment, and 0.77 for light microscopy. The mean time to read a negative smear was 1.4 min with fluorescence microscopy and 3.6 min with light microscopy, reflecting a time savings of 61% with fluorescence microscopy. CONCLUSION: LED fluorescence microscopy provides a reliable alternative to conventional methods and has many favorable attributes that facilitate improved, decentralized, diagnostic services.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lewinsohn, D. M., Leonard, M. K., LoBue, P. A., Cohn, D. L., Daley, C. L., Desmond, E., Keane, J., Lewinsohn, D. A., Loeffler, A. M., Mazurek, G. H., et al. (2017) · Clinical Infectious Diseases · doi:10.1093/cid/ciw694 · Cited by 992
“Alternative methods for rapid molecular DST are being developed and other technologies are likely to become available in the near future (eg, automated real-time PCR with sequencing, LAMP) [162].”
MethodTuberculous meningitis: a uniform case definition for use in clinical research
Marais, S., Thwaites, G., Schoeman, J. F., Török, M. E., Misra, U. K., Prasad, K., Donald, P. R., Wilkinson, R. J., & Marais, B. J. (2010) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(10)70138-9 · Cited by 932
Self-citationMycobacterium bovis at the animal–human interface: A problem, or not?
Michel, A. L., Müller, B., & van Helden, P. D. (2010) · Veterinary Microbiology · doi:10.1016/j.vetmic.2009.08.029 · Cited by 350
(2011) · PubMed · Cited by 7
Metadata
- Authors
- Marais, B. J., Brittle, W., Painczyk, K., Hesseling, A. C., Beyers, N., Wasserman, E., van Soolingen, D., & Warren, R. M.
- Venue
- Clinical Infectious Diseases
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-07-15
- Volume
- 47
- Issue
- 2
- Pages
- 203-207
- ISSN
- 1058-4838 (ISSN-L)
- 1537-6591
- OpenAlex
- W2108049621
- Cited by
- 161
- References
- 0
- FWCI
- 8.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.