Monitoring the Effectiveness of Hospital Cleaning Practices by Use of an Adenosine Triphosphate Bioluminescence Assay
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Objective.: To evaluate the usefulness of an adenosine triphosphate (ATP) bioluminescence assay for assessing the efficacy of daily hospital cleaning practices. Design.: A 2-phase prospective intervention study. Setting.: A university-affiliated community teaching hospital. Methods.: During phase I of our study, 5 high-touch surfaces in 20 patient rooms were sampled before and after daily cleaning. Moistened swabs were used to sample these surfaces and were then plated onto routine and selective media, and aerobic colony counts were determined after 48 hours of incubation. Specialized ATP swabs were used to sample the same high-touch surfaces in the 20 patient rooms and were then placed in luminometers, and the amount of ATP present was expressed as relative light units. During phase II of our study, after in-service housekeeper educational sessions were given, the housekeepers were told in advance when ATP readings would be taken before and after cleaning. Results.: During phase I, the colony counts revealed that the 5 high-touch surfaces were often not cleaned adequately. After cleaning, 24 (24%) of the 100 surface samples were still contaminated with methicillin-resistant Staphylococcus aureus, and 16 (16%) of the 100 surface samples still yielded vancomycin-resistant enterococci. ATP readings (expressed as relative light units) revealed that only bathroom grab bars and toilet seats were significantly cleaner after daily cleaning than before. During phase II, a total of 1,013 ATP readings were obtained before and after daily cleaning in 105 rooms. The median relative light unit was significantly lower (ie, surfaces were cleaner) after cleaning than before cleaning for all 5 high-touch surfaces. Conclusions.: Suboptimal cleaning practices were documented by determining aerobic colony counts and by use of an ATP bioluminescence assay. ATP readings provided quantitative evidence of improved cleanliness of high-touch surfaces after the implementation of an intervention program.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aycicek, H., Oguz, U., & Karci, K. (2006) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2005.09.007 · Cited by 164 · cited 1×
“c Median value (range) of 289 (10-130,960) before and 129 (14-9,103) after cleaning (P<.”
Monitoring the effectiveness of cleaning in four British hospitals
Cooper, R. A., Griffith, C. J., Malik, R. E., Obee, P., & Looker, N. (2007) · American Journal of Infection Control · doi:10.1016/j.ajic.2006.07.015 · Cited by 111
Cited by
McDonald, L. C., Gerding, D. N., Johnson, S., Bakken, J. S., Carroll, K. C., Coffin, S. E., Dubberke, E. R., Garey, K. W., Gould, C. V., Kelly, C., et al. (2018) · Clinical Infectious Diseases · doi:10.1093/cid/cix1085 · Cited by 2,690
Loveday, H. P., Wilson, J. A., Pratt, R. J., Golsorkhi, M., Tingle, A., Bak, A., Browne, J., Prieto, J., & Wilcox, M. (2014) · Journal of Hospital Infection · doi:10.1016/s0195-6701(13)60012-2 · Cited by 1,621
Dancer, S. J. (2014) · Clinical Microbiology Reviews · doi:10.1128/cmr.00020-14 · Cited by 679
Modern technologies for improving cleaning and disinfection of environmental surfaces in hospitals
Boyce, J. M. (2016) · Antimicrobial Resistance & Infection Control · doi:10.1186/s13756-016-0111-x · Cited by 442
Self-citationDisinfection and Sterilization in Health Care Facilities
Rutala, W. A., & Weber, D. J. (2016) · Infectious Disease Clinics of North America · doi:10.1016/j.idc.2016.04.002 · Cited by 222
“[58] [59] [60] [61] Health care facilities must also allow adequate time for room processing to ensure adherence to all steps recommended by institutional policies and professional organization guidelines.”
Gold, K. M., & Hitchins, V. M. (2013) · American Journal of Infection Control · doi:10.1016/j.ajic.2013.01.029 · Cited by 39
Metadata
- Authors
- Boyce, J. M., Havill, N. L., Dumigan, D. G., Golebiewski, M., Balogun, O., & Rizvani, R.
- Venue
- Infection Control & Hospital Epidemiology
- Publisher
- Cambridge University Press (CUP)
- Published
- 2009-07
- Volume
- 30
- Issue
- 7
- Pages
- 678-684
- ISSN
- 0899-823X (ISSN-L)
- 1559-6834
- OpenAlex
- W2072761448
- Cited by
- 244
- References
- 2
- FWCI
- 7.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.