CoChat

Comparison of 4 Different Types of Surgical Gloves Used for Preventing Blood Contact

Wittmann, Andreas, Kralj, Nenad, Köver, Jan, Gasthaus, Klaus, Lerch, Hartmut, Hofmann, Friedrich · 2010 · Infection Control & Hospital Epidemiology

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Abstract

Background.: Needlestick injuries are always associated with a risk of infection, because these types of punctures may expose healthcare workers to a patient's blood and/or body fluids. Objective.: To compare the efficacy of 4 different types of surgical gloves for preventing exposure to blood as a result of needlestick injury. Methods.: For simulation of needlestick injury, a circular sample of pork skin was tightened onto a bracket, and a single finger from a medical glove was stretched over the sample. First, a powder-free surgical glove with a gel coating was used to test blood contact. Second, a glove with a patented puncture indication system was used to test blood contact with a double-gloved hand. Third, 2 powder-free latex medical gloves of the same size and hand were combined for double gloving, again to test blood contact. Finally, we tested a glove with an integrated disinfectant on the inside. The punctures were carried out using diverse sharp surgical devices that were contaminated with 99 Tc-marked blood. The amount of blood contact was determined from the transmitted radioactivity. Results.: For the powder-free surgical glove with a gel coating, a mean volume of 0.048 μL of blood (standard error of the mean [SEM], 0.077 μL.) was transferred in punctures with an automated lancet at a depth of 2.4 mm through 1 layer of latex. For the glove with an integrated disinfectant on the inside, the mean volume of blood transferred was 0.030 μL (SEM, 0.0056 μL) with a single glove and was 0.024 μL (SEM, 0.003 μL) with 2 gloves. For the glove with the patented puncture indication system, a mean volume of 0.024 μL, (SEM, 0.003 μL) of blood was transferred. Conclusions.: Double gloving or the use of a glove with disinfectant can result in a decrease in the volume of blood transferred. Therefore, the use of either of these gloving systems could help to minimize the risk of bloodborne infections for medical staff.

Overview

Integrity signals

Registry

Crossref · 10.1086/652158

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 25 references

Research works printed but not linked: 12

  1. 2006, Cochrane Database Syst Rev, CD003087
  2. 2000, Dokumentationsband über 40. Jahrestagung der Deutsche Gesellschaft für Arbeitsmedizin und Umweltmedizin, 310
  3. 1996, Eur J Surg, 162, 941
  4. 2000, Arch Intern Med, 161, 2313
  5. 1993, J Bone Joint Surg Br, 75, 918
  6. 1996, Hyg Med, 21, 486
  7. 1999, Gesundheitswesen, 61, 398
  8. 2003, Eur J Surg, 166, 293
  9. 1991, Obstet Gynecol, 78, 1019
  10. 2007, Dokumentation der 46. Jahrestagung der Deutsche Gesellschaft für Arbeitsmedizin und Umweltmedizin, 653
  11. 1994, J Am Coll Surg, 178, 107
  12. 1994, J Am Coll Surg, 178, 107

Cited by

See all 19

Metadata

Authors
Wittmann, A., Kralj, N., Köver, J., Gasthaus, K., Lerch, H., & Hofmann, F.
Affiliations
  • University of Wuppertal (DE)
  • Helios Universitätsklinikum Wuppertal (DE)
Corresponding author
Wittmann, Andreas
Venue
Infection Control & Hospital Epidemiology
Published
2010-05
Volume
31
Issue
05
Pages
498-502
ISSN
  • 0899-823X (ISSN-L)
  • 1559-6834
OpenAlex
W2122898318
Cited by
19
References
25
Citations by year
2025: 1 · 2024: 2 · 2021: 2 · 2020: 1 · 2019: 2 · 2018: 1 · 2017: 1 · 2015: 1 · 2014: 1 · 2013: 4 · 2012: 2
FWCI
1.45
Type
journal article
Language
en
Open access
closed
Locations
  • Infection Control and Hospital Epidemiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Infectious Diseases › Infection Control in Healthcare
  • Health Sciences › Medicine › Surgery › Surgical site infection prevention
  • Life Sciences › Immunology and Microbiology › Microbiology › Medical Device Sterilization and Disinfection
Keywords
needlestick injuries, surgical gloves, blood contact, bloodborne infections, double gloving, latex gloves, glove powder, occupational exposure
MeSH terms
Animals, Equipment Design, Gloves, Surgical, Humans, Latex, Meat, Swine, Occupational Exposure, Needlestick Injuries, Blood-Borne Pathogens

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of 4 Different Types of Surgical Gloves Used for Preventing Blood Contact. https://app.cochat.ai/papers/10.1086/652158
The paper
Wittmann, A., Kralj, N., Köver, J., Gasthaus, K., Lerch, H., & Hofmann, F. (2010). Comparison of 4 Different Types of Surgical Gloves Used for Preventing Blood Contact. Infection Control & Hospital Epidemiology. https://doi.org/10.1086/652158

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.