Controlling Legionella in Hospital Drinking Water: An Evidence-Based Review of Disinfection Methods
The DOI matches its Crossref record.
Abstract
Hospital-acquired Legionnaires' disease is directly linked to the presence of Legionella in hospital drinking water. Disinfecting the drinking water system is an effective preventive measure. The efficacy of any disinfection measures should be validated in a stepwise fashion from laboratory assessment to a controlled multiple-hospital evaluation over a prolonged period of time. In this review, we evaluate systemic disinfection methods (copper-silver ionization, chlorine dioxide, monochloramine, ultraviolet light, and hyperchlorination), a focal disinfection method (point-of-use filtration), and short-term disinfection methods in outbreak situations (superheat-and-flush with or without hyperchlorination). The infection control practitioner should take the lead in selection of the disinfection system and the vendor. Formal appraisals by other hospitals with experience of the system under consideration is indicated. Routine performance of surveillance cultures of drinking water to detect Legionella and monitoring of disinfectant concentrations are necessary to ensure long-term efficacy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Copper Homeostasis at the Host-Pathogen Interface
Hodgkinson, V., & Petris, M. J. (2012) · Journal of Biological Chemistry · doi:10.1074/jbc.r111.316406 · Cited by 316
“For example, copper is used as a fungicidal application for plants (2) and as an electrolytic ionizer to combat Legionella in hospital drinking water (3), and in 2008, copper alloys became the first solid surfaces registered by the Environmental Protection Agency formarketing as an antimicrobial.”
BackgroundMetal‐based antimicrobial strategies
Turner, R. J. (2017) · Microbial Biotechnology · doi:10.1111/1751-7915.12785 · Cited by 202
“It is also now common to see Cu/Ag ionizers used for controlling Legionella in drinking water distribution systems in hospitals to mitigate nosocomial infections (Lin et al., 2011).”
BackgroundProbiotic Approach to Pathogen Control in Premise Plumbing Systems? A Review
Wang, H., Edwards, M. A., Falkinham, J. O., & Pruden, A. (2013) · Environmental Science & Technology · doi:10.1021/es402455r · Cited by 175
Metadata
- Authors
- Lin, Y. E., Stout, J. E., & Yu, V. L.
- Venue
- Infection Control & Hospital Epidemiology
- Publisher
- Cambridge University Press (CUP)
- Published
- 2011-02
- Volume
- 32
- Issue
- 2
- Pages
- 166-173
- ISSN
- 0899-823X (ISSN-L)
- 1559-6834
- OpenAlex
- W2149727845
- Cited by
- 167
- References
- 0
- FWCI
- 6.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.