Determination of complex shear modulus with thickness shear mode resonators
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
The electrical response of polymer-coated acoustic wave sensors depends on changes in the surface mass loading and changes in viscoelastic properties of the coating material. In this paper we consider the acoustic behaviour and the electrical response of a thickness-shear mode resonator on changes in shear parameters of the coating material at its fundamental frequency as well as its third and fifth harmonics. The changes in material properties were induced by temperature changes. Both a glassy and a rubbery polymer were investigated. The complex shear parameter and dynamic glass transition temperature were calculated from impedance measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Verwendung von Schwingquarzen zur W�gung d�nner Schichten und zur Mikrow�gung
Sauerbrey, G. (1959) · Zeitschrift f�r Physik · doi:10.1007/bf01337937 · Cited by 9,653
Williams, M. L., Landel, R. F., & Ferry, J. D. (1955) · Journal of the American Chemical Society · doi:10.1021/ja01619a008 · Cited by 8,083
Use of quartz vibration for weighing thin films on a microbalance
Sauerbrey, G., & Sauerbrey, F. (1959) · The European Physical Journal A · Cited by 6,791
The use of quarts oscillators for weighing thin layers and for microweighing
Sauerbrey, G., & Sauerbrey, G. (1959) · Medical Entomology and Zoology · Cited by 4,456
New equivalent circuits for elementary piezoelectric transducers
Krimholtz, R., Leedom, D. A., & Matthaei, G. L. (1970) · Electronics Letters · doi:10.1049/el:19700280 · Cited by 810
Piezoelectric Sorption Detector.
King, W. H. (1964) · Analytical Chemistry · doi:10.1021/ac60215a012 · Cited by 786
Martin, S. J., Frye, G. C., & Senturia, S. D. (1994) · Analytical Chemistry · doi:10.1021/ac00086a003 · Cited by 332
Self-citationRelaxation and thermodynamics in polymers : Glass transition
Donth, E.-J. (1992) · Cited by 318
Donth, E., Beiner, M., Reissig, S., Korus, J., Garwe, F., Vieweg, S., Kahle, S., Hempel, E., & Schröter, K. (1996) · Macromolecules · doi:10.1021/ma951881a · Cited by 129
Cited by
Reviakine, I., Johannsmann, D., & Richter, R. P. (2011) · Analytical Chemistry · doi:10.1021/ac201778h · Cited by 871
Acoustic Wave Microsensor Arrays for Vapor Sensing
Grate, J. W. (2000) · Chemical Reviews · doi:10.1021/cr980094j · Cited by 400
Janata, J., Josowicz, M., Vanýsek, P., & DeVaney, D. M. (1998) · Analytical Chemistry · doi:10.1021/a1980010w · Cited by 330
Phononic crystals for liquid sensor applications
Lucklum, R., & Li, J. (2009) · Measurement Science and Technology · doi:10.1088/0957-0233/20/12/124014 · Cited by 202
Self-citation
Metadata
- Authors
- Lucklum, R., Behling, C., Cernosek, R. W., & Martin, S. J.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 1997-02-07
- Volume
- 30
- Issue
- 3
- Pages
- 346-356
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W1965744094
- Cited by
- 183
- References
- 9
- FWCI
- 10.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.