Understanding the role of the gas in the voids during corona charging of cellular electret films - a way to enhance their piezoelectricity
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The influence of the corona-charging process on the piezoelectric transducer coefficient d 33 of a cellular electret film has been investigated. An increased corona voltage can be considered as a way to enhance the charge density and thus also the resulting piezoelectric effect. Higher corona-charging voltages are possible with increased ambient pressure or in suitable dielectric gases. The effect of the gas inside the voids has also been studied. Enhanced transducer coefficients were obtained by corona charging in N 2 or N 2 O gas atmospheres at 100-450 or 100-140 kPa pressures, respectively. The highest transducer coefficients of about 790 pCN -1 were obtained when N 2 gas was filled into the voids of a cellular polymer film by means of consecutive vacuum and high-pressure treatments at 295 or 313 K.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ElectroMechanical Film (EMFi) — a new multipurpose electret material
Paajanen, M., Lekkala, J., & Kirjavainen, K. (2000) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(99)00269-1 · Cited by 287
Self-citationPiezoelectricity in cellular electret films
Hillenbrand, J., & Sessler, G. M. (2000) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/94.868074 · Cited by 208
Modelling the electromechanical film (EMFi)
Paajanen, M., Välimäki, H., & Lekkala, J. O. (2000) · Journal of Electrostatics · doi:10.1016/s0304-3886(99)00065-0 · Cited by 107
Self-citationPorous PTFE space-charge electrets for piezoelectric applications
Gerhard, R., Künstler, W., Gome, T., Pucher, A., Weinhold, T. J., Seiß, M., Xia, Z., Wedel, A., & Danz, R. (2000) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/94.868065 · Cited by 105
Cited by
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Ferroelectrets: Soft Electroactive Foams for Transducers
Bauer, S., Gerhard-Multhaupt, R., & Sessler, G. M. (2004) · Physics Today · doi:10.1063/1.1688068 · Cited by 562
Self-citationNew materials for micro-scale sensors and actuators
Wilson, S. A., Jourdain, R. P. J., Zhang, Q., Dorey, R. A., Bowen, C. R., Willander, M., Wahab, Q. U., Willander, M., Al-hilli, S. M., Nur, O., et al. (2007) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2007.03.001 · Cited by 514
Self-citationGerhard-Multhaupt, R. (2002) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2002.1038668 · Cited by 296
Self-citationThakur, R., Das, D., & Das, A. (2013) · Separation & Purification Reviews · doi:10.1080/15422119.2012.681094 · Cited by 199
“The charge stability of the electret media was found to be enhanced by increasing the hydrophobicity of the medium through surface treatment like partial fluorination, in addition, this helps in reducing the effect of relative humidity on charge decay (75, 76).”
Background
Metadata
- Authors
- Paajanen, M., Wegener, M., & Gerhard-Multhaupt, R.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 2001-08-07
- Volume
- 34
- Issue
- 16
- Pages
- 2482-2488
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W1996571318
- Cited by
- 173
- References
- 4
- FWCI
- 9.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.