Plasmachemical oxidation processes in a hybrid gas–liquid electrical discharge reactor
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Oxidation processes induced in water by pulsed electrical discharges generated simultaneously in the gas phase in close proximity to the water surface and directly in the liquid were investigated in a hybrid series gas?liquid electrical discharge reactor. The mechanism of phenol degradation was studied through its dependence on the gas phase and liquid phase compositions using pure argon and oxygen atmospheres above the liquid and different initial pH values in the aqueous solution. Phenol degradation was significantly enhanced in the hybrid-series reactor compared with the phenol removal by the single-liquid phase discharge reactor. Under an argon atmosphere the mechanism of phenol degradation was mainly caused by the electrophilic attack of OH? radicals produced by the liquid phase discharge directly in water and OH? radicals produced by the gas phase discharge at the gas?liquid interface. Under an oxygen atmosphere the formation of gaseous ozone dominated over the formation of OH? radicals, and the contribution of the gas phase discharge in this case was determined mainly by the dissolution of gaseous ozone into the water and its subsequent interaction with phenol. At high pH phenol was degraded, in addition to the direct attack by ozone, also through indirect reactions of OH? radicals formed via a peroxone process by the decomposition of dissolved ozone by hydrogen peroxide produced by the liquid phase discharge. Such a mechanism was proved by the detection of cis,cis-muconic acid and pH-dependent degradation of phenol, which resulted in significantly higher removal of phenol from alkaline solution observed under oxygen atmosphere than in argon.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
(2014) · doi:10.1201/b17118 · Cited by 57,706
Decomposition of Ozone in Water: Rate of Initiation by Hydroxide Ions and Hydrogen Peroxide
Staehelin, J., & Hoigne, J. (1982) · Environmental Science & Technology · doi:10.1021/es00104a009 · Cited by 1,235
Rate constants of reactions of ozone with organic and inorganic compounds in water—II
Hoigné, J., & Bader, H. (1983) · Water Research · doi:10.1016/0043-1354(83)90099-4 · Cited by 948
Joshi, A. A., Locke, B. R., Arce, P., & Finney, W. C. (1995) · Journal of Hazardous Materials · doi:10.1016/0304-3894(94)00099-3 · Cited by 610
Self-citationOptical study of active species produced by a pulsed streamer corona discharge in water
Sun, B., Sato, M., & Clements, J. S. (1997) · Journal of Electrostatics · doi:10.1016/s0304-3886(97)00002-8 · Cited by 540
Ozonation in Organic Chemistry
(1982) · Elsevier eBooks · doi:10.1016/b978-0-12-073102-2.x5001-0 · Cited by 510
Generation of chemically active species by electrical discharges in water
Sunka, P., Babický, V, Clupek, M., Lukes, P., Simek, M., Schmidt, J., & Cernák, M. (1999) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/8/2/006 · Cited by 422
Self-citationGlaze, W. H., & Kang, J. W. (1989) · Industrial & Engineering Chemistry Research · doi:10.1021/ie00095a001 · Cited by 267
Oxidative Processes Occurring When Pulsed High Voltage Discharges Degrade Phenol in Aqueous Solution
Sun, B., Sato, M., & Clements, J. S. (2000) · Environmental Science & Technology · doi:10.1021/es990024+ · Cited by 240
Hydrogen Peroxide and Ozone Formation in Hybrid Gas–Liquid Electrical Discharge Reactors
Lukes, P., Appleton, A. T., & Locke, B. R. (2004) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.821799 · Cited by 219
Self-citation
Cited by
Non-thermal plasmas in and in contact with liquids
Bruggeman, P., & Leys, C. (2009) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/42/5/053001 · Cited by 1,285
Electrohydraulic Discharge and Nonthermal Plasma for Water Treatment
Locke, B. R., Sato, M., Sunka, P., Hoffmann, M. R., & Chang, J.-S. (2006) · Industrial & Engineering Chemistry Research · doi:10.1021/ie050981u · Cited by 1,181
Self-citationLukes, P., Dolezalova, E., Sisrova, I., & Clupek, M. (2014) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/23/1/015019 · Cited by 1,181
Self-citationPlasma-based water purification: Challenges and prospects for the future
Foster, J. E. (2017) · Physics of Plasmas · doi:10.1063/1.4977921 · Cited by 418
Boenig, H. (1982) · Cornell University Press eBooks · doi:10.7591/9781501741388 · Cited by 278
Physicochemical processes in the indirect interaction between surface air plasma and deionized water
Liu, Z. C., Liu, D. X., Chen, C., Li, D., Yang, A. J., Rong, M. Z., Chen, H. L., & Kong, M. G. (2015) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/48/49/495201 · Cited by 260
Shang, K., Morent, R., Wang, N., Wang, Y., Peng, B., Jiang, N., Lu, N., & Li, J. (2022) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.133916 · Cited by 252
Electron impact dissociation of oxygen-containing molecules–A critical review
McConkey, J. W., Malone, C. P., Johnson, P. V., Winstead, C., McKoy, V., & Kanik, I. (2008) · Physics Reports · doi:10.1016/j.physrep.2008.05.001 · Cited by 219
Jablonowski, H., & von Woedtke, T. (2015) · Clinical Plasma Medicine · doi:10.1016/j.cpme.2015.11.003 · Cited by 208
Aqueous‐Phase Chemistry of Electrical Discharge Plasma in Water and in Gas–Liquid Environments
Lukes, P., Locke, B. R., & Brisset, J. (2012) · Plasma Chemistry and Catalysis in Gases and Liquids · doi:10.1002/9783527649525.ch7 · Cited by 203
Self-citationAboubakr, H. A., Gangal, U., Youssef, M. M., Goyal, S. M., & Bruggeman, P. J. (2016) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/49/20/204001 · Cited by 187
“Cis–cis muconic acid is specific to ozone and is formed via 1,3-dipolar cycloaddition mechanism [39].”
Streamer-Like Electrical Discharges in Water: Part II. Environmental Applications
Joshi, R. P., & Thagard, S. M. (2013) · Plasma Chemistry and Plasma Processing · doi:10.1007/s11090-013-9436-x · Cited by 181
“The same effect was observed during the phenol removal from water using gas-phase electrical discharges [126] and other advanced oxidation technologies [127].”
BackgroundColonna, G., Pintassilgo, C. D., Pegoraro, F., Cristofolini, A., Popoli, A., Neretti, G., Gicquel, A., Duigou, O., Bieber, T., Hassouni, K., et al. (2021) · The European Physical Journal D · doi:10.1140/epjd/s10053-021-00186-5 · Cited by 25
Metadata
- Authors
- Lukes, P., & Locke, B. R.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 2005-11-07
- Volume
- 38
- Issue
- 22
- Pages
- 4074-4081
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W2081747241
- Cited by
- 218
- References
- 17
- FWCI
- 5.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.