Abstract
Atmospheric-pressure, non-equilibrium plasmas are susceptible to instabilities and, in particular, to arcing (glow-to-arc transition). Spatially confining the plasma to dimensions of 1 mm or less is a promising approach to the generation and maintenance of stable, glow discharges at atmospheric-pressure. Often referred to as microdischarges or microplasmas, these weakly-ionized discharges represent a new and fascinating realm of plasma science, where issues such as the possible breakdown of ' pd scaling' and the role of boundary-dominated phenomena come to the fore. Microplasmas are generated under conditions that promote the efficient production of transient molecular species such as the rare gas excimers, which generally are formed by three-body collisions. Pulsed excitation on a sub-microsecond time scale results in microplasmas with significant shifts in both the temperatures and energy distribution functions associated with the ions and electrons. This allows for the selective production of chemically reactive species and opens the door to a wide range of new applications of microplasmas. The implementation of semiconductor and microelectronics and MEMs microfabrication techniques has resulted in the realization of microplasma arrays as large as 250,000 devices. Fabricated in silicon or ceramics with characteristic device dimensions as small as 10 µm and at packing densities up to 10 4 cm −2 , these arrays offer optical and electrical characteristics well suited for applications in medical diagnostics, displays and environmental sensing. Several microplasma device structures, including their fundamental properties and selected applications, will be discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modelling of microdischarge devices: plasma and gas dynamics
Kushner, M. J. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/11/001 · Cited by 243
Direct current high-pressure glow discharges
Stark, R. H., & Schoenbach, K. H. (1999) · Journal of Applied Physics · doi:10.1063/1.369505 · Cited by 197
Self-citationExcimer emission from microhollow cathode argon discharges
Moselhy, M., Petzenhauser, I., Frank, K. H., & Schoenbach, K. H. (2003) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/36/23/009 · Cited by 102
Self-citationJiang, C., Mohamed, A. H., Stark, R. H., Yuan, J. H., & Schoenbach, K. H. (2005) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2005.851970 · Cited by 75
Self-citation
Cited by
Fridman, G., Friedman, G., Gutsol, A., Shekhter, A. B., Vasilets, V. N., & Fridman, A. (2008) · Plasma Processes and Polymers · doi:10.1002/ppap.200700154 · Cited by 2,084
Plasma–liquid interactions: a review and roadmap
Bruggeman, P. J., Kushner, M. J., Locke, B. R., Gardeniers, J. G. E., Graham, W. G., Graves, D. B., Hofman-Caris, R. C. H. M., Maric, D., Reid, J. P., Ceriani, E., et al. (2016) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/25/5/053002 · Cited by 1,725
von Woedtke, T., Reuter, S., Masur, K., & Weltmann, K.-D. (2013) · Physics Reports · doi:10.1016/j.physrep.2013.05.005 · Cited by 848
Brandenburg, R. (2017) · Plasma Sources Science and Technology · doi:10.1088/1361-6595/aa6426 · Cited by 802
Cold plasma selectivity and the possibility of a paradigm shift in cancer therapy
Keidar, M., Walk, R., Shashurin, A., Srinivasan, P., Sandler, A., Dasgupta, S., Ravi, R., Guerrero-Preston, R., & Trink, B. (2011) · British Journal of Cancer · doi:10.1038/bjc.2011.386 · Cited by 767
Metadata
- Authors
- Becker, K. H., Schoenbach, K. H., & Eden, J. G.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 2006-01-20
- Volume
- 39
- Issue
- 3
- Pages
- R55-R70
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W1991614017
- Cited by
- 902
- References
- 4
- FWCI
- 42.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.