Digital image correlation and fracture: an advanced technique for estimating stress intensity factors of 2D and 3D cracks
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Digital image correlation is a measurement technique that allows one to retrieve displacement fields ‘separating’ two digital images of the same sample at different stages of loading. Because of its remarkable sensitivity, it is possible to not only detect cracks with sub-pixel opening, which would not be visible but also to provide accurate estimates of stress intensity factors. For this purpose suitable tools have been devised to minimize the sensitivity to noise. Working with digital images allows the experimentalist to deal with a wide range of scales from the atomistic to the geophysical one with the same tools. Various examples are shown at different scales, as well as some recent extensions to three-dimensional cracks based on x-ray Computed micro-tomographic images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Horn, B. K. P., & Schunck, B. G. (1981) · Artificial Intelligence · doi:10.1016/0004-3702(81)90024-2 · Cited by 10,312
Horn, B. K., & Schunck, B. G. (1981) · SPIE Proceedings · doi:10.1117/12.965761 · Cited by 7,394
A finite element method for crack growth without remeshing
Mo�s, N., Dolbow, J., & Belytschko, T. (1999) · International Journal for Numerical Methods in Engineering · doi:10.1002/(sici)1097-0207(19990910)46:1<131::aid-nme726>3.0.co;2-j · Cited by 6,446
Elastic crack growth in finite elements with minimal remeshing
Belytschko, T., & Black, T. (1999) · International Journal for Numerical Methods in Engineering · doi:10.1002/(sici)1097-0207(19990620)45:5<601::aid-nme598>3.0.co;2-s · Cited by 4,880
Advances in atomic force microscopy
Giessibl, F. J. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.949 · Cited by 2,278
Applications of digital-image-correlation techniques to experimental mechanics
Chu, T. C., Ranson, W. F., & Sutton, M. A. (1985) · Experimental Mechanics · doi:10.1007/bf02325092 · Cited by 2,236
Determination of displacements using an improved digital correlation method
Sutton, M., Wolters, W., Peters, W., Ranson, W., & McNeill, Sr. (1983) · Image and Vision Computing · doi:10.1016/0262-8856(83)90064-1 · Cited by 1,927
Digital volume correlation: Three-dimensional strain mapping using X-ray tomography
Bay, B. K., Smith, T. S., Fyhrie, D. P., & Saad, M. (1999) · Experimental Mechanics · doi:10.1007/bf02323555 · Cited by 941
Electronmicroscopy and Analysis-1981
Goodhew, P. J., & Humphreys, J. F. (1984) · Solar Energy · doi:10.1016/0038-092x(84)90025-2 · Cited by 814
Besnard, G., Hild, F., & Roux, S. (2006) · Experimental Mechanics · doi:10.1007/s11340-006-9824-8 · Cited by 710
Self-citationHandbook of computer vision and applications
Jähne, B., Haussecker, H. W., & Geißler, P. (1999) · Academic Press eBooks · Cited by 697
Velocity determination in scenes containing several moving objects
Fennema, C. L., & Thompson, W. B. (1979) · Computer Graphics and Image Processing · doi:10.1016/0146-664x(79)90097-2 · Cited by 574
Advances in Two-Dimensional and Three-Dimensional Computer Vision
Sutton, M. A., McNeill, S. R., Helm, J. D., & Chao, Y. J. (2000) · Topics in Applied Physics · doi:10.1007/3-540-48800-6_10 · Cited by 503
Electron Microscopy and Analysis
Goodhew, P. J., Humphreys, J., & Humphreys, J. (2000) · CRC Press eBooks · doi:10.1201/9781482289343 · Cited by 389
Roux, S., & Hild, F. (2006) · International Journal of Fracture · doi:10.1007/s10704-006-6631-2 · Cited by 372
Self-citationCharacterization of internal damage in a MMCp using X-ray synchrotron phase contrast microtomography
Buffière, J., Maire, É., Cloetens, P., Lormand, G., & Fougères, R. (1999) · Acta Materialia · doi:10.1016/s1359-6454(99)00024-5 · Cited by 338
A three-dimensional digital image correlation technique for strain measurements in microstructures
Verhulp, E. E., van Rietbergen, B., & Huiskes, R. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.036 · Cited by 325
Effects Of Subpixel Image Restoration On Digital Correlation Error Estimates
Sutton, M. A., McNeill, S. R., Jang, J., & Babai, M. (1988) · Optical Engineering · doi:10.1117/12.7976778 · Cited by 247
A new microtensile tester for the study of MEMS materials with the aid of atomic force microscopy
Chasiotis, I., & Knauss, W. G. (2002) · Experimental Mechanics · doi:10.1007/bf02411051 · Cited by 243
Hild, F., Raka, B., Baudequin, M., Roux, S., & Cantelaube, F. (2002) · Applied Optics · doi:10.1364/ao.41.006815 · Cited by 190
Self-citationThree dimensional experimental and numerical multiscale analysis of a fatigue crack
Rannou, J., Limodin, N., Réthoré, J., Gravouil, A., Ludwig, W., Baïetto-Dubourg, M.-C., Buffière, J.-Y., Combescure, A., Hild, F., & Roux, S. (2010) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2009.09.013 · Cited by 175
Self-citationGuvenilir, A., Breunig, T. M., Kinney, J. H., et al. (1997) · Acta Materialia · doi:10.1016/s1359-6454(96)00311-4 · Cited by 105
Buffière, J., Ferrié, E., Proudhon, H., et al. (2006) · Materials Science and Technology · doi:10.1179/174328406x114135 · Cited by 100
Rastogi, P. (2000) · Topics in applied physics · doi:10.1007/3-540-48800-6 · Cited by 90
Correlation image velocimetry: a spectral approach
Roux, S., Hild, F., & Berthaud, Y. (2002) · Applied Optics · doi:10.1364/ao.41.000108 · Cited by 70
Self-citationBayesian multi-scale differential optical flow
Simoncelli, E. P. (1999) · Cited by 69
Cited by
Maire, E., & Withers, P. J. (2014) · International Materials Reviews · doi:10.1179/1743280413y.0000000023 · Cited by 1,374
Digital Volume Correlation: Review of Progress and Challenges
Buljac, A., Jailin, C., Mendoza, A., Neggers, J., Taillandier-Thomas, T., Bouterf, A., Smaniotto, B., Hild, F., & Roux, S. (2018) · Experimental Mechanics · doi:10.1007/s11340-018-0390-7 · Cited by 305
Self-citationFracture of sandstone characterized by digital image correlation
Lin, Q., & Labuz, J. F. (2013) · International Journal of Rock Mechanics and Mining Sciences · doi:10.1016/j.ijrmms.2012.12.043 · Cited by 279
A review of optical NDT technologies
Zhu, Y.-K., Tian, G.-Y., Lu, R.-S., & Zhang, H. (2011) · Sensors · doi:10.3390/s110807773 · Cited by 228
“With the help of DIC technology people can measure mechanical properties of different materials [35-41], fatigue and breakup of different materials [42-47], even for high-temperature objects [48], among which the measurement of strain and flaw can provide rich information for NDT.”
Background
Metadata
- Authors
- Roux, S., Réthoré, J., & Hild, F.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 2009-10-21
- Volume
- 42
- Issue
- 21
- Pages
- 214004
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W1967765898
- Cited by
- 273
- References
- 26
- FWCI
- 12.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.