Stimulation of wound healing by helium atmospheric pressure plasma treatment
The DOI matches its Crossref record.
Abstract
New experiments using atmospheric pressure plasma have found large application in treatment of living cells or tissues, wound healing, cancerous cell apoptosis, blood coagulation on wounds, bone tissue modification, sterilization and decontamination. In this study an atmospheric pressure plasma jet generated using a cylindrical dielectric-barrier discharge was applied for treatment of burned wounds on Wistar rats' skin. The low temperature plasma jet works in helium and is driven by high voltage pulses. Oxygen and nitrogen based impurities are identified in the jet by emission spectroscopy. This paper analyses the natural epithelization of the rats' skin wounds and two methods of assisted epithelization, a classical one using polyurethane wound dressing and a new one using daily atmospheric pressure plasma treatment of wounds. Systemic and local medical data, such as haematological, biochemical and histological parameters, were monitored during entire period of study. Increased oxidative stress was observed for plasma treated wound. This result can be related to the presence in the plasma volume of active species, such as O and OH radicals. Both methods, wound dressing and plasma-assisted epithelization, provided positive medical results related to the recovery process of burned wounds. The dynamics of the skin regeneration process was modified: the epidermis re-epitelization was accelerated, while the recovery of superficial dermis was slowed down.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
von Woedtke, T., Reuter, S., Masur, K., & Weltmann, K.-D. (2013) · Physics Reports · doi:10.1016/j.physrep.2013.05.005 · Cited by 848
Atmospheric pressure dielectric barrier discharges interacting with liquid covered tissue
Tian, W., & Kushner, M. J. (2014) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/47/16/165201 · Cited by 367
Cold Atmospheric Plasma: A Powerful Tool for Modern Medicine
Braný, D., Dvorská, D., Halašová, E., & Škovierová, H. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21082932 · Cited by 354
Plasma Medicine: A Field of Applied Redox Biology
VON WOEDTKE, T., SCHMIDT, A., BEKESCHUS, S., WENDE, K., & WELTMANN, K.-D. (2019) · In Vivo · doi:10.21873/invivo.11570 · Cited by 318
Clinical Plasma Medicine: State and Perspectives of in Vivo Application of Cold Atmospheric Plasma
von Woedtke, T., Metelmann, H. ‐., & Weltmann, K. ‐. (2014) · Contributions to Plasma Physics · doi:10.1002/ctpp.201310068 · Cited by 249
White paper on plasma for medicine and hygiene: Future in plasma health sciences
Bekeschus, S., Favia, P., Robert, E., & von Woedtke, T. (2019) · Plasma Processes and Polymers · doi:10.1002/ppap.201800033 · Cited by 171
Comparison of six simulation codes for positive streamers in air
Bagheri, B., Teunissen, J., Ebert, U., Becker, M. M., Chen, S., Ducasse, O., Eichwald, O., Loffhagen, D., Luque, A., Mihailova, D., et al. (2018) · Plasma Sources Science and Technology · doi:10.1088/1361-6595/aad768 · Cited by 161
Helium Atmospheric Pressure Plasma Jet Effects on Two Cultivars of Triticum aestivum L.
Burducea, I., Burducea, C., Mereuta, P.-E., Sirbu, S.-R., Iancu, D.-A., Istrati, M.-B., Straticiuc, M., Lungoci, C., Stoleru, V., Teliban, G.-C., et al. (2023) · Foods · doi:10.3390/foods12010208 · Cited by 31
Self-citation
Metadata
- Authors
- Nastuta, A. V., Topala, I., Grigoras, C., Pohoata, V., & Popa, G.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 2011-02-21
- Volume
- 44
- Issue
- 10
- Pages
- 105204
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W2008596725
- Cited by
- 231
- References
- 0
- FWCI
- 8.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.