Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 271

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

The ultrasonic pulse-echo technique as applied to adhesion testing

Open access
Tattersall, H G·1973·Journal of Physics D: Applied Physics

Abstract

Flaws are commonly detected by their ability to reflect a burst of ultrasound back to a piezoelectric transducer, and a flaw is taken to be found if an ultrasonic reflection is detected. In this form, relying simply upon the existence or otherwise of a signal, the pulse-echo technique is not suited to the detection of weak bonding between an adherend and an adhesive, because both perfect and imperfect interfaces between dissimilar materials always reflect ultrasound. In 1971 Rolls-Royce sponsored an investigation into a highly developed form of pulse-echo technique, in which all the information from the reflected pulse is used, expressed in terms of accurate amplitude and phase measurements. It has been found possible to detect `slackness' at an interface, in situations where this slackness is not severe enough to amount to an actual unbond.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0022-3727/6/7/305

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Metadata

Authors
Tattersall, H. G.
Venue
Journal of Physics D: Applied Physics
Published
1973-05-01
Volume
6
Issue
7
Pages
819-832
ISSN
0022-3727 (ISSN-L)
OpenAlex
W2020141257
Cited by
271
References
2
FWCI
1.89
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The ultrasonic pulse-echo technique as applied to adhesion testing. https://app.cochat.ai/papers/10.1088/0022-3727/6/7/305
The paper
Tattersall, H. G. (1973). The ultrasonic pulse-echo technique as applied to adhesion testing. Journal of Physics D: Applied Physics. https://doi.org/10.1088/0022-3727/6/7/305

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.