Components of cathode erosion in vacuum arcs
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The composition of cathode mass loss was analysed for cadmium, copper and molybdenum vacuum arcs. It showed that two dominant flows are present, one consisting of ions, the other of molten droplets which have sizes in the order of microns to tens of microns. The droplet flow is mainly oriented along the cathode plane and is strongly dependent on the fusion temperature of the cathode metal and the charge transfer by the arc. The cathode mass loss in vapour form is considered to be small.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Algorithm for Least-Squares Estimation of Nonlinear Parameters
Marquardt, D. W. (1963) · Journal of the Society for Industrial and Applied Mathematics · doi:10.1137/0111030 · Cited by 30,728
Waterdrop collisions with solid surfaces
Engel, O. G. (1955) · Journal of research of the National Bureau of Standards · doi:10.6028/jres.054.033 · Cited by 319
Metadata
- Authors
- Daalder, J. E.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 1976-11-11
- Volume
- 9
- Issue
- 16
- Pages
- 2379-2395
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W2045730859
- Cited by
- 377
- References
- 2
- FWCI
- 4.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Components of cathode erosion in vacuum arcs. https://app.cochat.ai/papers/10.1088/0022-3727/9/16/009
- The paper
- Daalder, J. E. (1976). Components of cathode erosion in vacuum arcs. Journal of Physics D: Applied Physics. https://doi.org/10.1088/0022-3727/9/16/009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.