The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
The fluxgate magnetometer
Open accessAbstract
Presents a review of fluxgate magnetometry based on a survey of the literature and on the work of the author and colleagues. The theory is outlined and an evaluation of the merit of the different types of sensors is made based on the sensor geometry. The design of a second-harmonic feedback magnetometer is discussed with respect to sensor configuration, frequency response, noise, offset, temperature dependence and long-term stability. Examples of the parameters are compiled from the literature and some new results on the long-term stability are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The fluxgate mechanism, part I: The gating curves of parallel and orthogonal fluxgates
Primdahl, F. (1970) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1970.1066795 · Cited by 138
Self-citationStuart, W. F. (1972) · Reports on Progress in Physics · doi:10.1088/0034-4885/35/2/306 · Cited by 57
A fluxgate sensor of high stability for low field magnetometry
Gordon, D., Lundsten, R. H., Chiarodo, R., & Helms, H. H. (1968) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1968.1066332 · Cited by 48
Temperature compensation of fluxgate magnetometers
Primdahl, F. (1970) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1970.1066971 · Cited by 32
Self-citationMagnetometers for space measurements over a wide range of field intensities
Ledley, B. G. (1970) · Revue de Physique Appliquée · doi:10.1051/rphysap:0197000501016400 · Cited by 14
A miniature fluxgate magnetometer with sub-gamma noise
Brown, R. (1972) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1972.1067356 · Cited by 5
Cited by
Microelectromechanical systems (MEMS): fabrication, design and applications
Judy, J. W. (2001) · Smart Materials and Structures · doi:10.1088/0964-1726/10/6/301 · Cited by 828
Current Sensing Techniques: A Review
Ziegler, S., Woodward, R. C., Iu, H. H.-C., & Borle, L. J. (2009) · IEEE Sensors Journal · doi:10.1109/jsen.2009.2013914 · Cited by 774
Ripka, P. (1992) · Sensors and Actuators A: Physical · doi:10.1016/0924-4247(92)80159-z · Cited by 385
Monitoring system for photovoltaic plants: A review
Madeti, S. R., & Singh, S. N. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.09.088 · Cited by 313
Magnetoresistive Sensor Development Roadmap (Non-Recording Applications)
Zheng, C., Zhu, K., Cardoso de Freitas, S., Chang, J.-Y., Davies, J. E., Eames, P., Freitas, P. P., Kazakova, O., Kim, C., Leung, C.-W., et al. (2019) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2019.2896036 · Cited by 268
Metadata
- Authors
- Primdahl, F.
- Venue
- Journal of Physics E: Scientific Instruments
- Publisher
- IOP Publishing
- Published
- 1979-04
- Volume
- 12
- Issue
- 4
- Pages
- 241-253
- ISSN
- 0022-3735 (ISSN-L)
- OpenAlex
- W2057275436
- Cited by
- 499
- References
- 6
- FWCI
- 5.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The fluxgate magnetometer. https://app.cochat.ai/papers/10.1088/0022-3735/12/4/001
- The paper
- Primdahl, F. (1979). The fluxgate magnetometer. Journal of Physics E: Scientific Instruments. https://doi.org/10.1088/0022-3735/12/4/001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.